D812958 00100_03
38
- RIGEL 6
INSTALLATION MANUAL
ACCESS MENUS Fig. 1
stat
- +
- +
OK
vers
bft . . .
+
/
-
OK
0000
+
/
-
+
/
-
n. cycles
OK
OK
01.33
00
- +
err
autoset
02.01
........
30.15
+
/
-
Exit Menù
Confirm/Switch on display
Scroll up
Scroll down
See PARAMETERS MENU
See LOGIC MENU
See RADIO MENU
hidden butt
release
desired button
Add. 2ch
language
n. remotes
List of last 30 errors
Control unit
software version
No total manoeuvres(in hundreds)
No radio controldevices memorised
ALT
follow the user guide
x2
0---
10--
150-
1520
ok
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
***
hidden butt
release
desired button
hidden butt
release
desired button
Add. 4ch
hidden butt
release
desired button
Add. 1ch
Add. 3ch
erase 64
For AUTOSET menu,
see simplified menu
If cancelled
If not present
If clone, it is disabled
(
0001
)
ok
KO
dis
erase 1
Diagnostics
code
DESCRIPTION
NOTES
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
PED
PED pedestrian input activated
TIME
TIMER input activation or activation time band
STOP
STOP input activated
PHOT
Activation of PHOT photocell input or, if configured as
verified photocell, Activation of the associated FAULT input
PHOP
Activation of PHOT OP opening photocell input or, if
configured as active verified photocell only when opening,
Activation of the associated FAULT input
PHCL
Activation of PHOT CL closing photocell input or, if configured
as active verified photocell only when closing, Activation of
the associated FAULT input
BAR
Activation of BAR safety edge input or, if configured as
verified safety edge, Activation of the associated FAULT input
baro
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE OPENING, or, if configured as verified safety edge active
only while opening, Activation of the associated FAULT input
barc
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE CLOSING, or, if configured as verified safety edge active
only while closing, Activation of the associated FAULT input
SWC1
SWC1 motor 1 closing limit switch input activated
SWO1
SWO1 motor 1 opening limit switch input activated
SWC2
SWC2 motor 2 closing limit switch input activated
SWO2
SWO2 motor 2 opening limit switch input activated
ER01
Photocell test failed
Check photocell connection and/or logic settings
ER02
Safety edge test failed
Check safety edge connection and/or logic settings
ER03
Opening photocell test failed
Check photocell connection and/or parameter/logic setting
ER04
Closing photocell test failed
Check photocell connection and/or parameter/logic setting
er06
8k2 safety edge test failed
Check safety edge connection and/or parameter/logic settings
ER07
Opening safety edge test failed
Check safety edge connection and/or parameter/logic settings
ER08
Closing safety edge test failed
Check safety edge connection and/or parameter/logic settings
ER1x
*
Board hardware test error
- Check connections to motor
- Hardware problems with board (contact technical
assistance)
ER3x
*
Reverse due to obstacle - Amperostop
Check for obstacles in path
ER70, ER71
ER74, ER75
Internal system supervision control error.
Try switching the board off and back on again. If the
problem persists, contact the technical assistance
department.
ER72
Consistency error of the control unit’s parameters (Logics
and Parameters)
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
The board settings must be checked
(Parameters
and Logics)
ER73
D-track parameter error
Pressing OK, the board will keep on working with
D-track as a default.
An autoset is required
ERf3
Error in setting the SAFE inputs
Check the setting of the SAFE inputs is correct
ERF9
Solenoid lock output overload
-Check lock connections
- Unsuitable lock
*
X
= 0, 1, .., 9, A, B, C, D, E, F