1) SET TO MANUAL OPERATION

 - 

Disengage the drive gear by using the 

triangular key and turning clockwise.

2) SET THE CLOSE LIMIT

 - Push the gate to its fully closed position. Remove the screw 

that holds the proximity sensor at the front end of the actuator. Slide it back so that the 

back end of the sensor housing is 3-1/2” from the center of the drive carriage and re-

attach screw that secures sensor in place. 

3) SET THE OPEN LIMIT

 - Push the gate to its 

fully open position. Remove the screw that 

holds the proximity sensor closest to the 

actuator body. Slide it forward so that the back 

end of the sensor housing is 3-1/2” from the 

center of the drive carriage and re-attach screw 

that secures sensor in place. 

3-1/2”

4) RE-ENGAGE THE MANUAL RELEASE

 - Use triangular key and turn 

counterclockwise to re-engage gears.

SETTING THE LIMITS

5) FINE-TUNING THE LIMITS

 – Once the actuator is connected to the controller, it 

must be powered and the limits might have to be fine-tuned by slidong them to the 

correct position.

Содержание PHOBOS N BT

Страница 1: ...installation manual version 120626 Phobos N BT Phobos N L BT tuned to you Professional installation required...

Страница 2: ...DE 3 max hinge offset 32 1 2 37 Maximum hinge offset does not apply to push to open applications APPLICATIONS CAPACITIES Important This product is intended to be installed and serviced by a profession...

Страница 3: ...L 325 VEHICULAR GATE CLASSIFICATION UL 325 ENTRAPMENT PROTECTION REQUIREMENTS UL 325 INSTALLATION RECOMENDATIONS OPERATIONAL SAFETY 5 GENERAL SAFETY CHECKING INSTALLATION ADJUSTING OPERATING FORCE CON...

Страница 4: ...upplied for exposed rollers 2 The operator is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall...

Страница 5: ...e leaf both to close and to open it CONTROL There are various options when it comes to the control system manual remote control access control with magnetic badge etc depending on the installation s n...

Страница 6: ...S PAGE 9 ATTACH THE ACTUATORS TO THE MOUNTING BRACKETS PAGE 9 SET THE LIMIT SWITCHES PAGE 10 PROCEED TO INSTALL THE CONTROLLER FINE TUNE THE LIMITS SENSORS INSTALL THE SNAP RINGS TECH SUPPORT U S TOLL...

Страница 7: ...ome cases When installing the post bracket two distances are taken in consideration A the parallel distance from the center of the hinge of the gate to the center of the pivot point of the actuator an...

Страница 8: ...er of the actuator s pivot point to the center of the attach point of the gate bracket GATE BRACKET MOUNTING Model C Phobos N BT 27 5 32 Phobos N L BT For push to open installations C must be measured...

Страница 9: ...supplied rubber grommet for the cable must be installed to keep moisture out of the motor limit board 2 ATTACH THE ACTUATOR Follow illustrations to install the actuator to the post and gate brackets...

Страница 10: ...place 3 SET THE OPEN LIMIT Push the gate to its fully open position Remove the screw that holds the proximity sensor closest to the actuator body Slide it forward so that the back end of the sensor ho...

Страница 11: ...rt number I101115 Do not apply grease if gears are dirty If necessary clean with degreaser before applying PHOBOS UNDERSIDE SCREW DRIVE REFER TO THE CONTROLLER INSTALLATION MANUAL FOR TROUBLESHOOTING...

Страница 12: ...been used for installing the motorization The failures are the result of tampering or improper repairs The failures have been caused by improper or careless use The causes of the failure are due to ex...

Отзывы: