USER’S MANUAL
ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product’s performance. The product is supplied with
a “
Warnings
” leaflet and an “
Instruction booklet
”. These should both be
read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product is in
conformity with the following European Directives: 89/336/EEC, 73/23/EEC,
98/37/EEC (and subsequent amendments).
1) GENERAL OUTLINE
The
DEIMOS BT-MA
actuator offers ample installation versatility thanks
to its compactness, the extremely low position of its pinion as well as the
height and depth adjustments available. The adjustable electronic torque
limiter ensures antisquash safety. The emergency manual manoeuvre can be
activated very easily by means of a knob. The end-of-run stop is controlled
by electromechanical limit microswitches. The control unit is incorporated.
Before each manoeuvre, the control unit performs a check of the operation
relays and safety devices (photocells, rubber skirt, etc.).
The following optional accessories are available:
- SBBAT mod. Buffer battery kit
It can be incorporated into the actuator, and allows the automation system to
operate even when the mains power supply is disconnected for a short time.
- MSC mod. Release knob
(fig.2)
Fixed release knob with personalised key.
2) SAFETY
If correctly installed and used, this automation device satisfies the required
safety level standards. However, it is advisable to observe some practical
rules in order to avoid accidental problems.
Before using the automation device, carefully read the operation instructions
and keep them for future reference.
• Keep children, persons and things outside the automation working area,
particularly during operation.
• Keep radio control or other control devices out of children’s reach, in
order to avoid any unintentional automation activation.
• Do not intentionally oppose the leaf movement.
• Do not attempt to open the gate by hand, if the actuator has not been
released by means of the appropriate release knob.
• Do not modify the automation components.
• In case of malfunction, disconnect the power supply, activate the emer-
gency release to gain access to the actuator and request the assistance
of a qualified technician (installer).
• Before proceeding to any external cleaning operation, disconnect the
mains powers supply and at least one of the battery pole, if fitted.
• Keep the photocell optical components and luminous signal indication
devices clean. Check that the safety devices (photocells) are not obscured
by branches or shrubs.
• For any direct assistance to the automation system, request the assistance
of a qualified technician (installer).
• Have qualified personnel check the automation system once a year.
3) MANUAL RELEASE
The manual or emergency release is to be activated when a gate must
be opened by hand, and in all cases where the automation system fails to
operate or operates incorrectly. To carry out the emergency manoeuvre,
proceed as follows:
• Insert the standard key into its appropriate seat (fig. 1) and rotate it an-
ticlockwise (90°), then rotate the release knob clockwise along its entire
stroke. This way the pinion is made to idle, and therefore allows the gate
to be opened by hand.
Warning: Do not push the gate leaf hard, but rather help it along its
entire stroke.
• To reset motor-driven control, rotate the knob anticlockwise along its entire
stroke, and then rotate the standard key clockwise until it is held tight. Keep
the key in a safe place which is known to all the people concerned.
In the case where the release knob is supplied with a personalised key
(fig.2), proceed as follows:
• Insert the personalised key into the lock, rotate the key anticlockwise by
90°.
• Hold the release knob and rotate it clockwise (fig. 2) until it stops. This
way the pinion is made to idle, and therefore allows the gate to be opened
by hand.
• Push the gate leaf by hand, helping it along its entire stroke.
The key cannot be taken out of the lock until the knob is brought back to
its initial position (motor-driven activation).
• To reset motor-driven control, rotate the knob anticlockwise along its entire
stroke, move the key back to its locking position; then take the key out
and keep it in a safe place which is known to all the people concerned.
4) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified
personnel regularly
.
The materials making up the set and its packing must
be disposed of according to the regulations in force.
Inspect the installation frequently to check that there are no signs of wear
or damage to the springs or supports. If any maintenance work is deemed
necessary, do not use the operator.
WARNINGS
Correct controller operation is only ensured when the data contained in
the present manual are observed. The company is not to be held respon-
sible for any damage resulting from failure to observe the installation
standards
and the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
Fig. 1
OPEN
CLOSE
Fig. 2
1
2
OPEN
CLO
SE
1
2
OPEN
CLOSE
MSC
4 -
DEIMOS BT-MA Ver. 11
D811343_11
Содержание DEIMOS BT + QSC D MA
Страница 2: ...2 DEIMOS BT MA Ver 11 D811343_11 ...
Страница 63: ...DEIMOS BT MA Ver 11 63 D811343_11 ...
Страница 64: ......