1) GENERAL OUTLINE (Fig.1)
Cellula 50 Mod recessed photocell to be fitted externally, consisting of a
pair of transmitters and receivers having a double relay which is normally
energised, as provided for by the relevant standards.
2) TECHNICAL SPECIFICATIONS
Power supply
:15 - 30 V~
Absorbed power
:6.85 VA
Max range
:30m (reduced in case of fog / rain)
Relay contacts
:1A at 24V~-
Working temperature
:-10°C to +70°C
Degree of protection
:IP54
3) PHOTOCELL FITTING
The photocells should be installed between 40 and 60 cm in height,
in the following ways:
-
In the case of a masonry pillar, dig a hole where to insert the plastic
container supplied, which is to be secured by concrete filling (fig. 1).
-
In the case of an iron pillar, make a hole using a ø 60 cutter where
to insert the plastic container supplied. To secure the container,
make three ø 2.7 holes for fastening the three self-tapping screws
supplied (fig. 2).
-
If there is no pillar or wall for the photocells to be secured to, request
the appropriate metal posts. The posts can be directly secured onto a
concrete base by means of three screw anchors (fig. 3).
Perfect alignment to the wall is ensured by the adjustment slots
provided in the base.
4) CONNECTION TO THE TERMINAL BOARD (Fig. 4)
Transmitter - Receiver
1-2 Power supply
3-4
Normally closed contact (When photocells are aligned the contact
opens).
3-5
Normally open contact (When photocells are aligned the contact
closes).
Warning! The installation must be carried out by qualified personnel.
5) PHOTOCELL ALIGNMENT
Correct alignment between the receiver and the transmitter is achieved
by adjusting the appropriate V (vertical) and O (horizontal) screws (fig.
5), until maximum luminosity of the internal L LED is obtained.
A voltameter can also be fitted to the two P pins to indicate maximum
voltage (3 V
) which corresponds to maximum alignment.
6) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by
qualified personnel regularly. The materials making up the set and its
packing must be disposed of according to the regulations in force.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any
alterations deemed appropriate for the technical, manufacturing
and commercial improvement of the product, while leaving the
essential product features unchanged, at any time and without
undertaking to update the present publication.