INSTALLATION MANUAL
“collective receivers” mode, as well as manage the complete installation database
using the
EEdbase
software.
The receiver is programmed by connecting universal palmtop programmer
to the
ALTAIR-P
control panel, using the
UNIFLAT
and
UNIDA
accessories, as
shown in fig. 4.
7.4) MANUAL PROGRAMMING
In the case of standard installations where advanced functions are not required,
you can proceed to manual storage of the transmitters, making reference to fig.
B for basic programming.
- If you wish the transmitter to activate output 1 (START) by means of key1, key2,
key3 or key4, enter the transmitter in menu “Start key”, as in fig. B.
- If you wish the transmitter to activate output 2 (2nd radio channel relay) by
means of key1, key2, key3 or key4, enter the transmitter in menu “2nd ch. key”,
as in fig. B.
Note:
Hidden key P1 appears differently depending on the transmitter model.
For transmitters with hidden key, press hidden key P1 (fig. B1). For transmit-
ters without hidden key, the key P1 function corresponds to simultaneously
pressing the 4 transmitter keys or, after opening the battery compartment,
bridging the two P1 points by means of a screwdriver (fig. B2).
IMPORTANT NOTE: ATTACH THE ADH ESIVE KEY LABEL TO THE FIRST MEMO-
RISED TRANSMITTER (MASTER).
In the case of manual programming, the first transmitter assigns the key code
to the receiver; this code is necessary in order to carry out subsequent cloning
of the radio transmitters.
7.5) RADIO-TRANSMITTER CLONING
Rolling-code cloning / Fixed-code cloning
Make reference to the universal palmtop programmer Instructions and the CLONIX
Programming guide.
7.6) ADVANCED PROGRAMMING: COLLECTIVE RECEIVERS
Make reference to the universal palmtop programmer Instructions and the CLONIX
Programming guide.
8) SERIAL CONNECTION USING SCS1 BOARD (Fig.5)
The
ALTAIR-P
control panel allows several automation units (SCS1) to be con-
nected in a centralised way by means of appropriate serial inputs and outputs.
This makes it possible to use one single command to open and close all the
automation units connected.
Following the diagram in Fig.5, proceed to connecting all the
ALTAIR-P
control
panels, exclusively using a telephone-type line.
Should a telephone cable with more than one pair be needed, it is indispensable
to use wires from the same pair.
The length of the telephone cable between one appliance and the next must
not exceed 250 m.
At this point, each of the
ALTAIR-P
control panels must be appropriately con-
figured, by setting a MASTER unit first of all, which will have control over all the
others, to be necessarily set as SLAVE (see logic menu).
Also set the Zone number (see parameter menu) between 0 and 127.
The zone number allows you to create groups of automation units, each one
answering to the Zone Master unit.
Each zone can only be assigned one Master
unit, the Master unit in zone 0 also controls the Slave units in the other zones.
9) CONNECTION OF THE ELECTRIC LOCK
EBP: see Fig. 6A
ECB: see Fig. 6B
N.B. The radio transmitters must be stored in the 2nd radio channel. The output
of the 2nd radio channel controls the “ME” board.
16
-
ALTAIR-P
D811506_04