background image

beyerdynamic GmbH & Co. KG 
Theresienstr. 8 | 74072 Heilbronn – Germany
Tel. +49 (0) 71 31 / 617 - 0 | Fax +49 (0) 71 31 / 617 - 224
[email protected] | www.beyerdynamic.de

For further distributors worldwide, please go to www.beyerdynamic.com
Non-contractual illustrations. Contents subject to change without notice. E3/MCS-D 3673 (07.09)

MCS-D 3673

System Unit

1 of 7

F

EATURES

• Shielded fully metal housing for 

“under the table installations”

• Use as chairman or delegate 

microphone unit possible

• Connections for operating panel, button, 

gooseneck microphone, headphone and 
loudspeaker via 9-pin / 25-pin / 37-pin Sub-D, 
5-pin XLR or Phoenix 

D

ESCRIPTION

The MCS-D 3673 system unit has been designed for “under the table 
installations” in conference rooms.  
The MCS-D 3673 provides different connections to connect external components
such as an operating panel (CA 3621/ 3623/ 3671/ 3673) or button, gooseneck
microphone and loudspeaker via 9-pin / 25-pin / 37-pin Sub D, 5-pin XLR and
Phoenix terminals. 
The MCS-D 3673 can be used as a chairman unit with microphone, clear and
priority buttons (e.g. by using the CA 3623 operating panel) or as a delegate
unit with one microphone button (e.g. by using the CA 3621 operating
panel). 
The microphone button is used to turn the microphone on or off. By using the
priority button the chairman can interrupt the discussion and mute all 
activated delegate microphone units. By using the clear button the chairman
can turn off all activated delegate microphone units.
If the microphone unit is to provide voting functions and channel 
selection, the CA 3673 operating panel must be used for the chairman
microphone unit and the CA 3671 operating panel must be used for the 
delegate microphone unit. 

The system unit is powered via the bus cable and can be placed 
anywhere in the bus network. 
The operating mode of the microphone unit is configured via the MCS-D 200
control unit or the iCNS software. 
In the standard mode (free switching on) the participant can use the micro-
phone button to switch the microphone on or off.
In the request-to-speak mode the microphone button is used to enter a 
request-to-speak. The delegate can deactivate the request-to-speak by 
pressing the microphone button once more. 
In the automatic mode, the participant’s request is registered once the maximum
number of active microphones has been exceeded. If a participant switches
off his/her microphone, the microphone unit is switched on automatically.
In the  FiFo (first in - first out) mode, the delegates speak in succession. The 
delegate can use the microphone button to switch on the microphone. If the
maximum number of open microphones is exceeded, the microphone of the
speaker who has been speaking the longest is switched off.

O

PTIONAL

A

CCESSORIES

CA 3621

Delegate operating panel, 
with microphone connection,
microphone button and 
loudspeaker . . . . . . . . . . . . . . . . . . . Order # 488.097

CA 3623

Chairman operating panel, 
with microphone connection,
microphone, clear and 
priority buttons and 
loudspeaker . . . . . . . . . . . . . . . . . . . Order # 488.100

CA 3641

Delegate operating panel, 
with microphone connection,
microphone button, 
loudspeaker, display and 
language selector . . . . . . . . . . . . . . . Order # 488.119

CA 3643

Chairman operating panel, 
with microphone connection,
microphone, clear and 
priority buttons, loudspeaker, 
display and language selector . . . . . . Order # 488.127

CA 3671

Delegate operating panel, 
with microphone connection,
microphone button, loudspeaker, 
language selector, display and 
voting buttons. . . . . . . . . . . . . . . . . . Order # 488.135

CA 3673

Chairman operating panel, 
with microphone connection,
microphone, clear and priority 
buttons, loudspeaker, 
language selector, display
and voting buttons . . . . . . . . . . . . . . Order # 488.143

SHM 214 E

Cardioid condenser ,
gooseneck microphone, 
length 400 mm, with rigid 
tube, plug-in type,
XLR connector and LED ring,
without pre-amp . . . . . . . . . . . . . . . . Order # 464.635

CA 1220

Loudspeaker . . . . . . . . . . . . . . . . . . . Order # 454.254

Содержание MCS-D 3673

Страница 1: ...ork The operating mode of the microphone unit is configured via the MCS D 200 control unit or the iCNS software In the standard mode free switching on the participant can use the micro phone button to...

Страница 2: ...ANELS CA 3621 3623 CA 3641 3643 3671 3673 CA 3641 CA 3643 CA 3671 CA 3673 TECHNICAL SPECIFICATIONS Frequency response Headphone 130 Hz to 17 000 Hz Loudspeaker 300 Hz to 12 000 Hz Microphone 200 Hz to...

Страница 3: ...71 3673 operating panel and MCS D 200 control unit CA 3673 CA 3673 CA 3673 CA 43xx cable max 45 microphone units redundant cabling recommended for more than 40 microphone units CA 4146 external power...

Страница 4: ...d external CA 4146 power supply unit button SHM 214 MCS D DT 1 S button SHM 214 MCS D DT 1 S button SHM 214 MCS D DT 1 S MCS D 3673 CA 43xx cable max 45 microphone units redundant cabling recommended...

Страница 5: ...24 info beyerdynamic de www beyerdynamic de For further distributors worldwide please go to www beyerdynamic com Non contractual illustrations Contents subject to change without notice E3 MCS D 3673 0...

Страница 6: ...o beyerdynamic de www beyerdynamic de For further distributors worldwide please go to www beyerdynamic com Non contractual illustrations Contents subject to change without notice E3 MCS D 3673 07 09 M...

Страница 7: ...31 617 224 info beyerdynamic de www beyerdynamic de For further distributors worldwide please go to www beyerdynamic com Non contractual illustrations Contents subject to change without notice E3 MCS...

Отзывы: