bewell connect MyTensio BW Скачать руководство пользователя страница 1

BewellConnect - BW-BW1 - User Manual - 022017v1

BewellConnect - BW-BW1 - User Manual - 022017v1

52

1

BW-BW1

BW-BW1

My

Tensio

North American market /

Marché Nord Américain

European market /

Marché Européen

BEWELLCONNECT CORP

185 Alewife Brook Parkway 410

CAMBRIDGE - MA 02138 - USA

support.bewell-connect.com

www.bewell-connect.com

VISIOMED GROUP SA

112, Avenue Kléber

75116 PARIS - France

[email protected]

Tel : +33 (8) 92 350 366

(0,34

/mn)

www.visiomed-lab.com

www.bewell-connect.fr

MANUFACTURED FOR

Содержание MyTensio BW

Страница 1: ...ch Nord Am ricain European market March Europ en BEWELLCONNECT CORP 185 Alewife Brook Parkway 410 CAMBRIDGE MA 02138 USA support bewell connect com www bewell connect com VISIOMED GROUP SA 112 Avenue...

Страница 2: ...AF8T BW BW1 SN Serial number Year Month Day Serial number SN SN Serial number BLOODPRESSUREMONITOR Model BW BW1 Rating 3 7V 300mAhLi ionPolymerBattery MeasurementRange 40 180bpm min0 299mmHg Manufactu...

Страница 3: ...BewellConnect BW BW1 User Manual 022017v1 5 BW BW1 BW BW1 MyTensio EN...

Страница 4: ...ded purpose as described in these instructions This unit can be used for personal use at home Use this unit within an ambient temperature range between 50 F and 104 F 10 C and 40 C Donotexposethisunit...

Страница 5: ...onsiderably throughout the day and these variations are even more significant in hypertensive subjects It is lower in the morning and increases in the afternoon and the evening When sleeping it decrea...

Страница 6: ...and they must be re validated in each case with a physician It is important to check your targets especially in cases of serious illness or preg nancy 3 CHARACTERISTICS Oscillometric method measures...

Страница 7: ...nplug the USB cable Avoid eating smoking or exercising 30 minutes before measurement Stay calm in the 15 minutes before taking your blood pressure Stressraisesyourbloodpressure Avoidtakingbloodpressur...

Страница 8: ...sure monitor 4 8 MEASUREMENT DIAGNOSIS The application automatically evaluates the MAM Mean Arterial Measurement and uses AHA color coding in interpreting the results 5 CLEANING AND MAINTENANCE Useaso...

Страница 9: ...rvous during the measurement Try again when you are calmer without talking or moving during the test Arrhythmia The unit is not suitable for people with a serious cardiac arrhythmia The blue colored B...

Страница 10: ...munications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be...

Страница 11: ...improper installation fire damage flood lightning or any other natural disaster The Bewellconnect device limited warranty does not cover product packaging accessories or any defective appearance due t...

Отзывы: