background image

 

BC 402 Compact Card Reader 

Programming 

Doc. No. 016/1  

Page 4 

 

 

BC 402 Compact Card Reader 

Combined User&Installation Guide 

Doc. No. 016/1  

Page 1 

The BC 402 Compact Card reader is a self contained 
magnetic card reader requiring only a Locking 
mechanism and a Power Supply for a complete 
single door solution. 
 
All programming is achieved by means of magnetic 
cards either provided with the unit or as a separate 
card pack. 
The unit is supplied with 2 Metre cables, where all 
terminations are made for the lock, Exit Request 
Button and the Power Supply. There are no user 
serviceable parts inside the reader. 

Installation.

 

 
The BC 402 may be installed externally without the need for heaters. The 
recommended mounting height is between 1.2 to 1.4 metres, in a vertical orientation 
with the small arrow pointing downwards. All fixing screws and clips are provided 
with the BC 402. 
 
The cables should be passed through to the secure side of the door for termination to 
the Lock, Power Supply and Exit Request Button. 
 
The cable connections are as follows: 
 

White 

Pair 

    Lock 

Output

    

(Note:- The ribbed or marked core is positive)

 

 
 Black 

Pair 

    Power 

Supply 

 

Grey 

Pair 

    Exit 

Request 

Button 

(If required)

Programming the system ( Day to Day). 

There are three programming functions available; 
 
 

1) Validating User Cards for the reader 

 
 

2) Deleting User Cards from the reader 

 
 

3) Setting Lock Opening Time. 

 

 

Logging on the User Cards

 

 
Each User Card has a corresponding paper Shadow Card 
 
To validate a User Card, first swipe through one of the Shadow cards.  The Green arrow LED will 
flash, and the other LEDs will go out 
 
Now swipe the required User Card.  The Green arrow LED will go steady, there will be a 
confirmation bleep and the three LEDs will come back on. 
 
If the above indications do not happen, the card(s) may have been mis-read. (A mis-read is 
accompanied by a falling tone from the unit.)   Simply try again, ensuring that the card is kept 
vertical and is swiped at a steady rate. 
 
After the User Card has been logged on, write the User details (Name & Card No.) on the Shadow 
Card.  This may then be used as a record for administration of the system. 
 
More User Cards can be validated now or at any time (200 Max ). 
 

 

Deleting User Cards.

 

 
To remove a User Card from the reader, it is a simple matter of swiping the corresponding 
Shadow Card through the reader.  The Shadow Card may now be re-used to validate a different 
User Card. 
 
 

 

Setting the Door Release Time

 

 

After initialisation, the Release Time is set to 7 seconds.  To change the this time, swipe the 
Master card through the reader and after the required time has elapsed, swipe the card again. Do 
not swipe any cards through the reader during this time 
 
 During the "wait" period all the LEDs will go out and there will be a bleep at one second 
intervals to aid the timing. 