background image

9

ELECTROMAGNETIC COMPATIBILITY INFORMATION

Technical Description Concerning Electromagnetic Emission

Table 1: Declaration - electromagnetic emissions

Guidance and manufacturer’s declaration - electromagnetic emissions

The model TL 70 is intended for use in the electromagnetic environment specified below.  

The customer or the user should assure that it is used in such an environment.

Emissions test

Compliance

Electromagnetic environment – guidance

RF emissions

CISPR 11

Group 1

The models TL 70 use RF energy only for its 

internal function. Therefore, its RF emissions are 

very low and are not likely to cause any interfe-

rence in nearby electronic equipment.

RF emissions

CISPR 11

Class B

The model TL 70 is suitable for used in domestic 

establishment and in establishment directly con-

nected to a low voltage power supply network 

which supplies buildings used for domestic 

purposes.

Harmonic emissions

IEC 61000-3-2

Class C

Voltage fluctuations/

flicker emissions

IEC 61000-3-3

Not applicable

Содержание TL 70

Страница 1: ...EN Daylight therapy lamp Instruction for use 2 ELECTROMAGNETIC COMPATIBILITY INFORMATION 9 TL 70 0598...

Страница 2: ...ss This hormone tells the body when it is time to sleep In the months when there is less sunlight therefore production of melatonin increases This makes it harder to get up in the morning since the bo...

Страница 3: ...ble to other users and observe the information they contain Safety notes Warning The light of the daylight therapy lamp is only intended for use on the human body Before use ensure that all packaging...

Страница 4: ...unit can be dangerous and may cause injury or improper results The main material of the case is made of PC ABS Be cautious of potential allergic reactions to these ma terials General notes Important...

Страница 5: ...t 6 Operation 1 Insert the mains part into the connector 2 Switch on the light Press the ON OFF button 3 LED display timer The daylight therapy lamp TL 70 indicates your current treatment time with th...

Страница 6: ...n the distance Distance Duration Up to 10 cm hour day Up to 25 cm 1 hour day Up to 40 cm 2 hours day Basically the closer you are to the source of light the less time you should use it 7 Enjoying ligh...

Страница 7: ...m Operating conditions 5 C to 35 C 15 90 relative humidity atmospheric pressure range 86 106 kpa Storage conditions 20 C to 50 C 15 90 relative humidity atmospheric pressure range 86 106 kpa Product c...

Страница 8: ...first in stance see the attached International Service list of service addresses The buyer will then receive further information about the processing of the warranty claim e g where they can send the...

Страница 9: ...t Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The models TL 70 use RF energy only for its internal function Therefore its RF emissions are very low and are not likely...

Страница 10: ...cal commercial or hospital environment Surge IEC 61000 4 5 1 kV line to line 2 kV line to earth 2 kV line to earth Mains power quality should be that of a typical commercial or hospital environment Vo...

Страница 11: ...trengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur In the vicinity of equip...

Страница 12: ...ing a minimum distance between portable and mobile RF communications equipment transmitters and the model TL 70 as recommended below according to the maximum output power of the communica tions equipm...

Отзывы: