Safety photocell CPSET M13 for protection against access
The safety photocell CPSET-M13 is used as contactless acting safeguard for
protection against access without muting function.
1 Control
unit
2
Protected area (photocell curtain)
Control unit
A blue illuminated pushbutton which serves as reset pushbutton is installed in
the control unit. The reset pushbutton signalises the control state of the safe-
guard. When the system has been started, the reset pushbutton is not illumi-
nated. When the protected area is free and the reset pushbutton has been
pressed and released, the safeguard is activated. The reset pushbutton is illumi-
nated in blue.
Danger!
An unauthorised release could result in severe personal injury or death.
Before releasing the start/restart interlock, the operator has to ensure that no
persons are within the danger zone.