3G-
β
3-EC-130412-001
User Manual
DIGITAL SPEAKER CONTROLLER
C4800
24 BIT DIGITAL CROSSOVER SYSTEM PROCESSOR
1
2
3
4
5
6
7
8
LIMITER
MUTE
-6
-10
OVER
-20
COMP
INPUT
OUTPUT
Para
Страница 1: ...001 User Manual DIGITAL SPEAKER CONTROLLER C4800 C4800 24 BIT DIGITAL CROSSOVER SYSTEM PROCESSOR 1 2 3 4 5 6 7 8 LIMITER MUTE 6 10 OVER 20 COMP MUTE 6 10 OVER 20 INPUT OUTPUT LIMITER MUTE 6 10 OVER 2...
Страница 2: ...ain Menu 7 2 Browse Configuration Program 7 3 Call the Configuration Program 7 4 Modify ID Number 8 BUILT IN SIGNAL PROCESSING 9 SOFTWARE 10 DEFINITION OF PORT 11 SPECIFICATIONS TABLE OF CONTENTS 6 6...
Страница 3: ...or plug in the cord Do not pull out or touch the cord with wet hand or it will cause the risk of electric shock Power supply cords should be routed so that they are not likely to be walked upon or pin...
Страница 4: ...max 4 seconds 6 way LED signal indicates the status of each input and output dynamic LCD displayed information of program and device 40 groups of configure programs is available for the user 1 USB co...
Страница 5: ...menu 5 Up button for parameter selection 6 Down button for parameter selection 7 Output channel mute button 8 Input channel signal level indicator and mute status indicator 9 Onput channel signal lev...
Страница 6: ...iguration program 7 DISPLAYS AND OPERATION 7 1 Main Menu Switch on power The display will show program name you are using as following Select YES NO by up or down button then push Para button to carry...
Страница 7: ...ent ratio 2 Output Channel Delay Delay Max delay for each output channel is 2 seconds Max delay for each channel is 4 seconds input output delay can be adjustment separately 3 Crossover HPF LPF Freque...
Страница 8: ...evice Then you will have monitor information of each device on software Attention please make sure different ID No for each device when you have more than one device connected 01 02 03 49 50 RS485 PC...
Страница 9: ...g Double click your device you will have the way how to connect Download data from PC to Device means apply existed parameter to the device without save You will have last saved parameter when you pow...
Страница 10: ...ck program under menu of program list after connected facility with software Select the serial No you want to save then click save as You can modify parameter of program name and recall or delete of c...
Страница 11: ...or 2 Facility No and information indicator Indicate data of facility number program number program name and connection status 9 4 Signal Process Module 9 4 1 PEQ Please reference point 8 for how to mo...
Страница 12: ...FTWARE 9 4 3 Input Delay Adjustable range of input Delay is 0 2 seconds total range 0 4 seconds 9 4 4 Output Delay Adjustable range of output Delay is 0 2 seconds 9 4 5 HPF LPF Parameter selection of...
Страница 13: ...channel mark input and output channel with curve The value from A to H can be adjusted by the volume on right side Adjustable range is 12 90 dB 9 5 EQ Xover Curve The graph shows synthesis of frequen...
Страница 14: ...ut and output terminal This equipment is equipped with pluggable terminal and signal definition as shown in above Communication port Remote input control port RS 485 Remote output control port RS 485...
Страница 15: ...20Hz20KHz 0 5 3dB Dynamic range 110dB A THD Noise 0 006 Min delay 1 2ms Remote control port RS 485 connector XLR input and output Others Input Power Voltage AC 110 220V 50Hz Power Consumption 24W max...
Страница 16: ...www beta3pro com C4800...