Beta LaserMike DataPro 500 Скачать руководство пользователя страница 6

 

   

DataPro 500 Operator Guide

 

/ General Safety Information 

 

 

General Safety Information  

 

Under NO circumstances should the earth safety connections 
be broken – internal damage to sensitive electronic components 
may occur and at worst electrocution to personnel may result.  

 

This equipment must be earthed/grounded.  

 

Relays and associated wiring are rated for SELV levels i.e. 60 
Vdc & 30 vac rms. These levels must not be exceeded.  

 

 Maintenance, repairs and electrical connections should be 
performed by a suitably qualified person for the country of 
installation.  

Intended Use   

If the equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.  

Laser Safety Precautions  

The laser beam in the optical sensor is very powerful and can permanently damage 

eyes not protected by laser safety glasses. To avoid exposing yourself to hazardous 

radiation, you must take these precautions:  

 

Never look into the laser beam. If you must look at the beam, 
view it from an angle and in the direction in which the beam is 
travelling.  

 

The beams emitted from the optical sensor are invisible to the 
unaided eye. Return the beam shutter to the closed position 
when the system is not in use or during setup.  

 

Ensure that all direct reflections are blocked.   

 

Remove all rings, watches, or jewelry from your hands when 
working on or near the sensor—can cause hazardous 
reflections.  

 

Never install the instrument at eye level.  

 

Operate the system only with people who have been instructed 
in laser safety.  

 

Post warning signs and lights that are active when laser is 
operating.  

 

 

Part No. MAN/EN5400-0001 

Page 6 of 14 

                Revision B (Jun 2010) 

Содержание DataPro 500

Страница 1: ...DATAPRO 500 OPERATOR GUIDE daily operation and routine maintenance www betalasermike com Manual Part Number MAN EN5400 0001 English Revision B Copyright Jun 2010...

Страница 2: ...f Conformity 5 General Safety Information 6 Intended Use 6 Laser Safety Precautions 6 Labels and Safety Features 7 Introduction 8 Operation 8 Key Switch 8 Programmable Indicator 9 Fuses 12 Cleaning 12...

Страница 3: ...its use and under conditions of its use EXCLUSIONS This warranty does not cover products which have been modified altered or repaired by any other party than Beta LaserMike or its authorized agents F...

Страница 4: ...on earth point using adequately sized cable or other means of connection Where supplied or specified shielded interconnection cables must be employed with this equipment to ensure compliance with the...

Страница 5: ...ide Declaration of Conformity DataPro 500 Operator Guide Declaration of Conformity Part No MAN EN5400 0001 Page 5 of 14 Revision B Jun 2010 Declaration of Conformity Part No MAN EN5400 0001 Page 5 of...

Страница 6: ...ser beam in the optical sensor is very powerful and can permanently damage eyes not protected by laser safety glasses To avoid exposing yourself to hazardous radiation you must take these precautions...

Страница 7: ...1 1986 For a copy of this document write to Laser Institute of America 13501 Ingenuity Drive Suite 128 Orlando Florida 32826 1 800 345 2737 Labels and Safety Features This section acquaints you with t...

Страница 8: ...ator has a front panel LED that can be configured along with the LaserSpeed to indicate status information Operation Key Switch The DataPro 500 front panel key switch provides laser power and beam shu...

Страница 9: ...Depending on the application the monitor is configured with different settings This section describes the general operation of the indicator and how to change settings In general operators do not con...

Страница 10: ...a complete reference Key Parameters for Users This section only pertains to situations where the indicator is programmed with setpoints The counter should be configured with a lockout code so that onl...

Страница 11: ...Press SEL to move to the 100ths position 5 Press RST key 5 times 6 Press SEL to move to the 10ths position 7 Press RST 4 times 8 Press SEL to move to the ones position 9 Press RST key 3 times 10 Pres...

Страница 12: ...l power lines The fuse holder can hold two x 1 or two 5mm x 20mm fuses If a fuse is blown it should be replaced with a fuse of the same type Cleaning Use a soft cloth moistened with water for cleaning...

Страница 13: ...laser to turn on Cooling heating may be required Run compressed air or 28 30 C water through sensor s coolant ports To avoid condensation the sensor temperature should not be allowed to go below dewpo...

Страница 14: ...a contact person to discuss the instrument failure When returning equipment for service it is important to first obtain a Return Material Authorization RMA number The RMA number is needed for proper...

Отзывы: