Beta LaserMike DataPro 500 Скачать руководство пользователя страница 4

 

   

DataPro 500 Operator Guide

 

European Commission Requirements 

 

 

European Commission Requirements 

This equipment is intended for use in a heavy industrial environment.  The equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to other equipment.  There is no guarantee that interference will not occur in a particular installation.  If 
this equipment does cause harmful interference to other equipment the user is encouraged to try to correct the 
interference by one or more of the following measures: 

- Re-orientate or relocate the equipment. 

- Increase the separation between the pieces of equipment. 

- Connect the pieces of equipment on separate mains circuits. 

- Ensure that the relevant items of equipment are properly and securely earthed to a common earth point using 
adequately sized cable or other means of connection.  

Where supplied or specified, shielded interconnection cables must be employed with this equipment to ensure 
compliance with the pertinent RF limits. Changes or modifications not expressly approved by the company could 
void the user’s authority to operate the equipment. 

This product has been rigorously tested to comply with the European EMC (Electromagnetic Compatibility) Directive. 
With regard to this, Beta LaserMike recommends that any non-Beta LaserMike peripheral equipment is CE marked 
for the Heavy Industrial environment (EN50082-2). Beta LaserMike also recommends that any cables not supplied 
by Beta LaserMike, but used for powering Beta LaserMike equipment, be built using good EMC practices (i.e. cables 
with braided shield, and connectors with 360

°

 termination of the braid to a metal/metalised shell connector at both 

ends). If you have any questions regarding this, contact the Beta LaserMike Service Department.  

Part No. MAN/EN5400-0001 

Page 4 of 14 

                Revision B (Jun 2010) 

Содержание DataPro 500

Страница 1: ...DATAPRO 500 OPERATOR GUIDE daily operation and routine maintenance www betalasermike com Manual Part Number MAN EN5400 0001 English Revision B Copyright Jun 2010...

Страница 2: ...f Conformity 5 General Safety Information 6 Intended Use 6 Laser Safety Precautions 6 Labels and Safety Features 7 Introduction 8 Operation 8 Key Switch 8 Programmable Indicator 9 Fuses 12 Cleaning 12...

Страница 3: ...its use and under conditions of its use EXCLUSIONS This warranty does not cover products which have been modified altered or repaired by any other party than Beta LaserMike or its authorized agents F...

Страница 4: ...on earth point using adequately sized cable or other means of connection Where supplied or specified shielded interconnection cables must be employed with this equipment to ensure compliance with the...

Страница 5: ...ide Declaration of Conformity DataPro 500 Operator Guide Declaration of Conformity Part No MAN EN5400 0001 Page 5 of 14 Revision B Jun 2010 Declaration of Conformity Part No MAN EN5400 0001 Page 5 of...

Страница 6: ...ser beam in the optical sensor is very powerful and can permanently damage eyes not protected by laser safety glasses To avoid exposing yourself to hazardous radiation you must take these precautions...

Страница 7: ...1 1986 For a copy of this document write to Laser Institute of America 13501 Ingenuity Drive Suite 128 Orlando Florida 32826 1 800 345 2737 Labels and Safety Features This section acquaints you with t...

Страница 8: ...ator has a front panel LED that can be configured along with the LaserSpeed to indicate status information Operation Key Switch The DataPro 500 front panel key switch provides laser power and beam shu...

Страница 9: ...Depending on the application the monitor is configured with different settings This section describes the general operation of the indicator and how to change settings In general operators do not con...

Страница 10: ...a complete reference Key Parameters for Users This section only pertains to situations where the indicator is programmed with setpoints The counter should be configured with a lockout code so that onl...

Страница 11: ...Press SEL to move to the 100ths position 5 Press RST key 5 times 6 Press SEL to move to the 10ths position 7 Press RST 4 times 8 Press SEL to move to the ones position 9 Press RST key 3 times 10 Pres...

Страница 12: ...l power lines The fuse holder can hold two x 1 or two 5mm x 20mm fuses If a fuse is blown it should be replaced with a fuse of the same type Cleaning Use a soft cloth moistened with water for cleaning...

Страница 13: ...laser to turn on Cooling heating may be required Run compressed air or 28 30 C water through sensor s coolant ports To avoid condensation the sensor temperature should not be allowed to go below dewpo...

Страница 14: ...a contact person to discuss the instrument failure When returning equipment for service it is important to first obtain a Return Material Authorization RMA number The RMA number is needed for proper...

Отзывы: