background image

SC0006104V00

Installation and User

Manual

Содержание slimline curve

Страница 1: ...SC0006104V00 Installation and User Manual...

Страница 2: ...product includes warning signs to confirm the non use of traditional disposal methods For more information contact your local authority or the store where you purchased this device C IMPORTANT SAFETY...

Страница 3: ...xtension cords as these can cause overheating and cau se a fire risk However in case of using an extension cord the cable must be the minimum size 14 AWG and with a power no less than 2500w The connec...

Страница 4: ...fety reasons the radiator should not be installed so that switches and other controls can be touched by a person in the bathroom or in the shower VERY IMPORTANT Read the installation manual before ass...

Страница 5: ...consisting of the following elements Tools required L R2 R1 I R N Yellow green Blue Blue Brown Power plate Display Brown or Black Ts L Phase N Neutral R1 Electronics neutral output R2 Electronics pha...

Страница 6: ...se a spirit level to ensure that the radiator is positioned correctly 5 Using the marks of the template make the holes that are needed 6 Using a drill drill the holes for the plugs appropriate to the...

Страница 7: ...0 1 C Setpoint temperature increases 0 5 C Measuring range ambient temperature 0 C 45 C Temperature selection range 5 C 30 C Weekly schedule Each 1h Maximum load resistive only 16A TRIAC 8 A 2000W Sup...

Страница 8: ...TO icon Manual The target room temperature remains fixed depending on the user s choice default 19 C In Manual mode press the key and to change the temperature The temperature will be fixed In this mo...

Страница 9: ...than the degrees configured in the comfort mode from 0 5 C to 29 5 C The antifreeze mode can be configured up to 0 5 C less than the degrees configured in the eco mode from 0 to 29 C Annotation The ra...

Страница 10: ...t modifying the time settings Another option when reaching 23 00 on day 7 is to press twice KEYPAD LOCKING Use this function to prevent any changes to your settings In a child room public area etc Pre...

Страница 11: ...OC Temperature probe not present SC Temperature probe shorted Err1 Actuating element in short circuit Err2 Overload more power than allowed Err4 Overheating 90 C in the electronics area I ECO DESIGN I...

Страница 12: ...Unit 7 Marrtree Business Park Grimbald Crag Close Knaresborough HG5 8FA Phone 01423 733000 Email info bestelectricradiators co uk...