BestCode Next Series 8 Technical Manual
October 2022
Page 140 of 290
Inspecting the Drop Breakup
1.
Set the starting values for Modulation,
Pressure, and Charge.
See Calibration Starting Values chart
3.
Run until the Viscosity is within range of
the Target Viscosity. (4.0-5.0cP)
4.
Inspect the breakup to visually determine
if the breakup is acceptable.
5.
If necessary, adjust the modulation
voltage until Good Breakup is achieved.
Calibrating the Modulation
1.
After visual inspection, set the
modulation to the voltage and
frequency with the best breakup.
2.
Make a test print using the default
message.
3.
Reduce the voltage by 10V and
print again.
4.
Repeat until a bad print in achieved.
5.
Set the modulation point to 30V
above the lowest acceptable print.
Lowest
Acceptable
20V over
30V over
Содержание Next 8 Series
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 142: ...BestCode Next Series 8 Technical Manual October 2022 Page 128 of 290 Photocell Auxiliary Serial ...
Страница 143: ...BestCode Next Series 8 Technical Manual October 2022 Page 129 of 290 USB ...
Страница 144: ...BestCode Next Series 8 Technical Manual October 2022 Page 130 of 290 Collector Information ...
Страница 258: ...BestCode Next Series 8 Technical Manual October 2022 Page 244 of 290 Appendix A Compliance Certificates ...
Страница 259: ...BestCode Next Series 8 Technical Manual October 2022 Page 245 of 290 ...
Страница 264: ...BestCode Next Series 8 Technical Manual October 2022 Page 250 of 290 ...
Страница 268: ...BestCode Next Series 8 Technical Manual October 2022 Page 254 of 290 ...
Страница 276: ...BestCode Next Series 8 Technical Manual October 2022 Page 262 of 290 Using the Molex Crimper ...
Страница 277: ...BestCode Next Series 8 Technical Manual October 2022 Page 263 of 290 ...