PLAN THE INSTALLATION

If you choose to mount the Flex Blower directly to the Downdraft 

housing: Remove the inlet cover (taped in place for shipping) 

and discard inlet cover. Refer to installation instructions in the 

Downdraft manual.
If you choose to mount the Flex Blower in a remote location, 

(such as the cabinet back, cabinet side, or floor joists) - follow 

the instructions below.

INSTALL FLEX BLOWER 
IN REMOTE LOCATION

NOTE: THE FLEX BLOWER MUST BE INSTALLED WITHIN 

4-FEET OF THE DOWNDRAFT’S ELECTRICAL PANEL.

The Electrical Panel can be mounted directly to the Downdraft 

housing - or mounted in a remote location (always within 4-feet 

of the Flex Blower).

1.  Position inlet cover over blower wheel. Securely attach the 

inlet cover to the blower with 8 screws and 8 nuts from parts 

bag. Note that inlet cover is taped to blower for shipping. This 

tape may be removed.

2.  Determine how the 8” round 

INLET

 and 

OUTLET

 ductwork 

will connect to the Flex Blower.

3.  Remove the necessary 1/4-20 x .50 hex head screws and attach 

4 MOUNTING BRACKETS

 to the Flex Blower - using 4 of the 

6 POSSIBLE BRACKET MOUNTING LOCATIONS

.

4.  Mount Flex Blower to back of cabinet, floor joist, or adequate 

framework (constructed by installer) with appropriate 

MOUNTING SCREWS (not included)

.

5.  Connect 

8” ROUND DUCT

 from Downdraft housing to Flex 

Blower inlet and from Flex Blower outlet to roof or wall cap.
For best performance: Choose the ducting option which allows 

the shortest length of ductwork and a minimum number of 

elbows and transitions. Check location of floor joists, wall 

studs, electrical wiring or plumbing for possible interference.

6.  Use strain relief bushing (provided) to attach Flex Blower wiring 

to wiring box on Downdraft’s electrical panel and make wiring 

connections. (See Downdraft manual for instructions.)

INLET

(from downdraft)

OUTLET

(to roof cap

or wall cap)

(6) MOUNTING 

BRACKET 

LOCATIONS

8-IN.

ROUND

DUCT

(to roof cap

or wall cap)

8-IN.

ROUND

DUCT

(from

downdraft)

MOUNTING SCREWS

(not included)

(4) MOUNTING 
BRACKETS
attached with
1/4-20 X .50 
HEX HEAD 
SCREWS

CONTENTS

These parts are included with your Flex Blower:
2 - blower mounting legs*
1 - Parts Bag containing:

(4) wood screws #10 x .50*
(4) blower mount brackets
(1) strain relief bushing
(8) screws #10 x .38
(8) nuts #10

For use when mounting Flex Blower directly to Downdraft 
housing. (See Downdraft instruction manual.)

BLOWER

INLET

COVER

Содержание PF6

Страница 1: ...ans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PER...

Страница 2: ...e 6 POSSIBLE BRACKET MOUNTING LOCATIONS 4 Mount Flex Blower to back of cabinet floor joist or adequate framework constructed by installer with appropriate MOUNTING SCREWS not included 5 Connect 8 ROUN...

Страница 3: ...mm 3 screws M4 x 0 7 x 16mm 1 screw M4 x 0 7 x 12mm 3 97020266 Blowerbox End Blower Mount 1 includes strain relief 4 99271511 Wire Harness 1 includes strain relief 5 98011179 Blower Mounting Legs 2 6...

Страница 4: ...is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NU...

Страница 5: ...Ne laissez pas la graisse s accumuler sur le ventilateur ou les filtres d Utilisez des casseroles de dimension appropri e Utilisez toujours une batterie de cuisine adapt e la dimension de la surface c...

Страница 6: ...lives du plancher ou une charpente ad quate construite par l installateur avec les VIS DE MONTAGE appropri es non incluses 5 Raccordez le CONDUIT ROND DE 8 PO 20 3 CM venant du bo tier de la hotte enc...

Страница 7: ...1 Vis M4 x 0 7 x 12 mm 1 3 97020266 Extr mit de bo tier de ventilateur Support de montage comprend bague antitraction 1 4 99271511 Faisceau de fils comprend bague antitraction 1 5 98011179 Pieds de mo...

Страница 8: ...territoires ou provinces interdisant de limiter la dur e d une garantie tacite la limitation ci dessus peut ne pas s appliquer votre situation L OBLIGATION POUR BROAN NUTONE DE R PARER OU DE REMPLACE...

Страница 9: ...frecuentemente los ventiladores No permita la acumulaci n de grasa en el ventilador ni en el filtro d Use una cacerola del tama o adecuado Siempre use utensilios de cocina que sean apropiados para el...

Страница 10: ...inete enlavigadelpisooenunaestructuraadecuada fabricadapor el instalador con los TORNILLOS DE MONTAJE adecuados no se incluyen 5 Conecte el CONDUCTO REDONDO DE 8 pulg 20 3 cm desde la cubierta de tiro...

Страница 11: ...x 0 7 x 16 mm 1 tornillo M4 x 0 7 x 12 mm 1 3 97020266 Extremo de la caja del ventilador montaje incluye alivio de refuerzo 1 4 99271511 Arn s de cables incluye alivio de refuerzo 1 5 98011179 Patas d...

Страница 12: ...do de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de vencimiento de una garant a impl cita por lo que la limitaci n antes mencionada p...

Отзывы: