background image

Play cricket scorer pro interface

Set-up and operating instructions

February 2019

www.bespokescoreboard.co.uk

Содержание Scoreboards Play cricket scorer pro

Страница 1: ...Play cricket scorer pro interface Set up and operating instructions February 2019 www bespokescoreboard co uk ...

Страница 2: ...installation 4 PCS Pro scoreboard configuration set up 5 PCS Pro interface operating instructions 7 How to connect 7 Wireless operation 7 Wired operation 7 PCS Pro interface LED s 8 PCS Pro interface buttons 8 Umpire s light 8 Refresh Scoreboard 8 Test pattern button 9 Reset button 9 PCS Pro set up fault diagnosis 11 Servicing 12 Contact Details 12 2 ...

Страница 3: ...h the following parts 1 x PCS Pro interface 1 x USB to Serial data cable 1 x Set up and operating instructions booklet If you have a wireless version you will also have 1 x 12 volt plug top power supply If you have a wired version you will need to use your existing data cable to power the PCS Pro interface from your scoreboard 3 ...

Страница 4: ...M port the cable has been allocated to The COM Port is the communication port allocated to the USB to serial cable This can be found by opening the Device Manager on your computer and clicking on Ports COM and LPT This will expand the sub menu to show all available COM ports You are looking for Prolific USB to Serial Comm Port Note down the allocated COM port on your computer as you will require i...

Страница 5: ...ttom box titled LED scoreboard FSL Controllers only requires setting up Click the Enabled box on the right so that it shows a tick Also click Include debug output Capitalise and using Cricket Scorelink device so that they all show a tick You now need to find the Command config file For our scoreboards you require bespoke scoreboards categories config Click the browse button opens the window in the...

Страница 6: ...nstallation The Baud Rate needs to be set at 9600 from the drop down menu In the advanced options set Data Bits to 8 and Stop Bits to 2 To set the Delay between commands click on the Edit button The default number of 2000 in the box becomes bolder and can now be edited Change this number to 10 and click on the Edit button again and the 10 will return to being grayed out Click Left pad numbers with...

Страница 7: ...econd delay the PCS Pro interface will send data to reset your scoreboard display Ensure that the aerial on the back of the PCS Pro interface is vertically aligned points straight up Please also make sure that your normal wireless Bespoke Scoreboard controller is turned off and not plugged into your scoreboard while you are using the PCS Pro interface otherwise it will prevent the PCS Pro interfac...

Страница 8: ...he ability to operate an umpires light on your scoreboard therefore we have added an Umpire s light button to the PCS Pro interface Press the umpires light button to illuminate the umpire s light on your Bespoke Scoreboard The umpire s light stays illuminated for as long as you press the button down Refresh Scoreboard Our standard scoreboard controllers transmit all the score data to our scoreboar...

Страница 9: ...rn button The test pattern button sends data to your Bespoke Scoreboard to display 8 s on all the digits on your scoreboard This button is largely for our benefit when servicing your scoreboard but is useful to you when your PCS Pro setup is not working correctly and you are looking for assurance that the PCS Pro interface is communicating with your scoreboard Reset button The reset button clears ...

Страница 10: ...inate when it does this 3 Send data from the PCS Pro interface to your scoreboard using the Reset and Test pattern buttons You should see the TX data LED illuminate while either of these buttons are pressed and your scoreboard should update with either 0 s 1 and 2 for the batsman s numbers or all 8 s If you tried to connect the PCS Pro interface to your scoreboard using the wireless link and this ...

Страница 11: ...hem resolved asap We are proud to provide scoreboards that work We designed and manufactured your PCS Pro scoreboard interface so should anything go wrong in the future we will be able to fix it Please call and discuss any issues you may have with your scoreboard We will be able to guide you to test and diagnose any faults with your system Spares and prices are available on our website 11 ...

Страница 12: ...Bespoke Scoreboards are designed and made in England by M Jay Electronics Limited Albion Mills Church Street Morley Leeds LS27 8LY phone 0113 252 4956 email david bespokescoreboards co uk or john bespokescoreboards co uk www bespokescoreboards co uk 12 ...

Отзывы: