Страница 1: ...BESANTEK N C t t BST HVD22 on on ac High Voltage Detector e INSTRUCTION MANUAL 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Страница 2: ...r Use 5 6 Checking and Proofing 5 7 Typical Uses 6 8 Broken Wires in Cables 6 9 High Voltage Testing 6 7 10 Faults Open Cables 8 11 Limitations of the Non contact High Voltage Detector 8 9 12 Changing Batteries 1O 13 Specifications 11 12 14 Limited Warranty 13 14 Caution risk of electric shock 6 Caution refer to the user manual ...

Страница 3: ...cessary precautions Do not exceed the limits of this Non contact high voltage detector The Non contact high voltage detector must never be in physical contact with any conductor higher than 1kV This is a proximity detector not a detector which works by contact Always use a fiber glass rod or any authorized stick A high voltage test is carried out with the Non contact high voltage detector attached...

Страница 4: ...sensor plate a rotary switch as sensitivity selector a sound annunciator high pitch high power buzzer and 3 LED indicators high bright LEDs in a circle for easier viewing by users in any directions This provides a 360 LED indication The Non contact high voltage detector detects AC voltages using the sensor plate The sensor plate collects part of the radiated electric field V M The electric field i...

Страница 5: ...ng The Non contact high voltage detector works by proximity Physical contact with electrical conductors is not necessary when testing for live lines Its sensor senses the radiated field which surrounds live conductors It is recommended not to touch high voltage wires with the Non contact high voltage detector Radiated field strength increases with voltage and decreases quickly with distance or ear...

Страница 6: ...tection Rotary selector with the settings listed below OFF Turn the pick up sensor off Test Check if the entire circuitry is working 240V 2kV 6kV 11kV 22kV 33kV 132kV 275kV Buzzer High noise level buzzer triggered on voltage detection Battery Holder Adapter end The adapter end connec f_ n for hot stick ...

Страница 7: ... buzzer of the Non contact high voltage detector should beep and the 3 LED indicators should light This indicates that the Non contact high voltage detector is operational Verify the working of this unit by selecting 240Vac and place the dome against a low voltage live conductor or rub the dome with a cloth or against an item of clothing as this generates a static DC which triggers the detection o...

Страница 8: ... detected by the Non contact high voltage detector and moving the tester along the cable until the change in condition is obtained Flexible cables as used in mining and building industries are readily repairable when the break in the cable is located 9 High Voltage Testing The rotary switch attenuator is used to identify and differentiate various HV live cables The Non contact high voltage detecto...

Страница 9: ...onjunction with an insulated rod or hot stick when measuring high voltage Check to see if the Non contact high voltage detector is in good operating condition Select the appropriate test range It is advised that you start with a lower test range setting than the actual working voltage Then perform the test again with the higher settings The user may also opt to use a lower setting to check for low...

Страница 10: ...or along the cable until you notice a change An audible sound and LED will be on when the sensor is on the supply side of the open and will turn off when on the other side ii I The ideal detection angle 11 Limitations of the Non contact High Voltage Detector It is recommended that this Non contact high voltage detector is not used in HV yards of mixed voltages In the presence of mixed voltages the...

Страница 11: ... HV and MV bus bars can trigger the detector when it is about 3m above the ground This is common with most of the electric field voltage detectors Users should be aware of it The tester can pick up adjacent circuit to the one being tested and indicates the wron information to the user Iii t For finding a break of cable 9 ...

Страница 12: ... using extension hot stick 12 Changing Batteries The Non contact high voltage detector uses 3 x 1 SV C type batteries Open the battery holder turn counter clockwise to remove the batteries Ensure the polarity is correct Then install the new batteries 10 ...

Страница 13: ...ox 600g Batteries included Power Source 1 5V C x 3 Alkaline Batteries Safety Standard EN 61326 1 CISPR 11 EN 61000 4 2 EN 61000 4 3 EN 61000 4 8 Accessories Instruction manual Disconnect hook Fuse extractor head Carry case Batteries 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Страница 14: ...BESANTEK Ul UI II lt _l I IUUI Fuse extractor head Carry case 12 ...

Страница 15: ...o any of our products which have been repaired or altered by unauthorized persons in any way In our sole judgement if the stability or reliability of products are injured or which have been subject to misuse abuse misapplication negligence or accident or the serial numbers have been altered defaced or removed this warranty will not apply All warranties implied by law are hereby limited to a period...

Страница 16: ...inue models at any time or change specification price or design without notice and without incurring any obligation 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...