background image

Amplifier Probe &

Tone Generator

BST-CT101

INSTRUCTION  MANUAL

Содержание BST-CT101

Страница 1: ...Amplifier Probe Tone Generator BST CT101 INSTRUCTION MANUAL ...

Страница 2: ...Index AMPLIFIER PROBE FEATURES INSTRUCTIONS MAINTENANCE TONE GENERATOR FEATURES INSTRUCTIONS MAINTENANCE Page 1 1 2 2 3 4 5 8 8 ...

Страница 3: ...e insulation Works with any Tone Generator to identify wires Volume control for increased sensitivity and adjustable to suit work environment Recessed ON OFF button prevents battery drain Power supply is in any 9V battery with a life of approximately 100 hours A plug receptacle is provided for head set or hand set Figure 1 Figure 2 ...

Страница 4: ... adjusted to suit the environment Volume can be increased to overcome noise or decreased to reduce interference Touch the tip of the amplifier probe to the insulation of each suspect conductor Reception of tone will be loudest on the subject wire The plug receptacle is provided for connecting to a head set or hand set MAINTENANCE The amplifier probe is maintenance free except for battery replaceme...

Страница 5: ... 3 Figure 4 Figure 3 TONE GENERATOR ...

Страница 6: ... display line polarity for Lines 1 and 2 The tone and continuity cont test functions are only applied to Line 1 using the modular plug A tone selector switch located inside the test set is provided for choosing either a fast dual alternating tone or a slow dual alternating tone CAUTION DO NOT CONNECT TO AN ACTIVE AC CIRCUIT EXCEEDING 24V IN THIS MODE Figure 5 fast slow ...

Страница 7: ...o the side of one line and the BLACK lead to the side of another line 2 The LED will glow GREEN when you connect the RED test lead to the RING SIDE of the line 3 The LED will glow RED when you connect the RED test lead to the TIP SIDE of the line Identifying line condition switch to off 1 Connect the RED test lead to the RING SIDE of the line and the BLACK to the TIP 2 Watch the LED 1 1 A BRIGHT G...

Страница 8: ...the subject line Sending tone switch to tone CAUTION DO NOT CONNECT TO ANY ACTIVE AC CIRCUIT EXCEEDING 24V IN THIS MODE 1 Connect the test leads to the pair or attach one lead to ground and one lead to either side of the line See figure 4 2 A fast dual alternating tone or a slow dual alternating tone can be selected from the switch inside the tone generator 3 Probe the suspected wires with the amp...

Страница 9: ... the line resistance exceeds 12kΩ Testing continuity using tone switch to tone CAUTION DO NOT CONNECT TO ANY ACTIVE AC OR DC CIRCUIT IN THIS MODE 1 Connect the test leads to the subject pair 2 Use a handset or headset at the remote end and touch the wire end s with the clip lead s 3 Reception of tone is an indication of continuity Modular testing All above tests are available through the modular p...

Страница 10: ... connect red to connector housing and black to center pin or red to connector housing and black to ground MAINTENANCE BATTERY REPLACEMENT INSTRUCTIONS 1 Separate the case install a fresh 9V battery and reassemble DO NOT OVER TIGHTEN 2 Warranty limited solely to repair or replacement no warranty of merchantability fitness for a particular purpose or consequential damages ...