background image

45(1 3/4")

63(2 1/2")

267(10 1/2")

125(4 15/16") 

36(1 7/16") 

43(1 11/16") 

7(1/4")

1st to 3rd rows

4th and 5th rows

Narrow

Shallow

Deep

Low

Middle

High

S-High

Sensitivity 

15sec.

60sec.

180sec. 

Presence

  timer

Setting 2

Setting 3

Setting 4

Setting 1

Frequency

Row

adjustment

5 rows

4 rows

3 rows

2 rows

Width 

R

L

Width 

R

L

Not 

applicable

 0°

35°

-3°

40°

30°

5730870

1 2 3 4

6 7 8

9 10 11 12

14

15

16

13

5

Wide

Narrow

Wide

1,2

3,4

5,6

7,8

Depth 

-6

°

6

°

Depth

26

°

44

°

Function key

Setting
mode

Operation

mode

Attention
For dipswitch setting, 
change it to "Setting 
mode". 
When setting finished, 
set it to "Operation 
mode".

Self

monitoring 

Immunity

ON

OFF

Disable

Enable

9

10

Safety / test

 outpu

t

Low

High

11 Test input

Low

High

12

N.O.

N.C.

14

Activation

output

20msec.
10msec.

13

Test input

delay

Installation

mode 16

ON

OFF

-6°

26°

44°

MANUFACTURER'S STATEMENT

DETECTION AREA

OUTER DIMENSIONS AND PART NAMES

SR221-2

ENGLISH

ORIGINAL

5917681  SEP

 2010

(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Depth angle adjustment screw
(5) Width adjustment screws
(6) Function key
(7) Dipswitches 
(8) Detection window  
(9) Area adjustment tool

Test conditions required by DIN 18650

Floor : Kodak Grey card
Detection object : 
     DIN 18650 Test body (Mat black)

Model 
Cover color
Mounting height
Detection area
Detection method
Depth angle
        adjustment
Power supply (*2 )

Power consumption
Operation indicator
Test input

Activation output

: SR221-2                   
: Black     
: 2.0 (6'6") to 3.0m (9'10")
: See 

DETECTION AREA

: Active infrared reflection (*1 )
: 1st to 3rd rows / -6  to +6°
  4th and 5th rows / +26  to +44°   
: 12 to 24VAC ±10% (50 / 60 Hz)
  12 to 30VDC ±10%             
: < 2.5W (< 4VA at AC)
: See chart below
: Opto coupler
  Voltage / 5 to 30VDC
  Current / 6mA Max. (30VDC)
: When 3rd, 4th or 5th row detects.
  Form A relay 
  50V 0.3A Max. (Resistance load)

Safety / Test output

Output hold time
Response time
Operating temperature
Operating humidity
IP rate
Category

Weight
Accessories

Performance level

: When 1st or 2nd row detects.
  Opto coupler (NPN)
  Voltage / 5 to 50VDC
  Current / 100mA Max.
  Dark current / 600nA Max. 
                     (Resistance load)

: Approx. 0.5 sec.
: <0.3 sec.
:  -20 to +55°C (-4 to 131°F)
: <80%     
: IP54
: 2 (EN ISO 13849-1 : 2008)
: d (EN ISO 13849-1 : 2008)
: 320g (11.2oz )  
: 1 Operation manual
  2 Mounting screws
  1 Mounting template
  1 Area adjustment tool
  1 Cable 3m (9'10")
   (8 × 0.22mm² AWG24 ) (*3 )

The specifications herein are subject to change without prior notice due to improvements.

NOTE

*1 : The 1st and 2nd rows have presence detection function.
*2 : When using this sensor, the sensor has to be connected to a door system which has the SELV circuit.
*3 : Overcurrent protection with less than 2A.

It is required to check the operation manual if this symbol is shown on the product.

MANUFACTURER'S STATEMENT

WARNING

Do not wash, disassemble, rebuild or repair the sensor, otherwise 
it may cause electric shock or breakdown of the equipment. 

Danger of electric shock.

WARNING

CAUTION

NOTE

Disregard of warning may cause the improper operation causing death or serious injury of 
a person.

Special attention is required to the section of this symbol.

Disregard of caution may cause the improper operation causing injury of a person or damage to 
objects. 

NOTE

Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or
death of a person.The meanings of the symbols are as follows.

1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door. 
    Do not use for any other applications. 
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
    the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which 
    the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building
    owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the 
   changed settings and the date shall be registered in the maintenance logbook accompanying the door.

The actual detection area may become smaller depending on the ambient light, the color / material of
the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than 
50mm / sec. or faster than 1500mm / sec.

NOTE

[mm (inch)]

Operation indicator

The values above are those of the detection area when tested referring to the test conditions of DIN 18650. 
(The emitting area is as shown in 

Emitting area

 above.)  

*: When installed at higher than 2.35m(7'8"), DIN 18650 requirements are fulfilled only within the area width "I" 
   of 3m(9'10").

To comply with DIN 18650, make sure that the detection area is within the values in the chart below.

DIN 18650-1:2010

DIN 18650-2:2010

EN 12978+A1:2009

EN 61696-3:2001 clause 4. 3. 5 and 5. 4. 7. 3

COMPLIED STANDARDS

1

3

2

CAUTION 

Risk of getting caught.

Make sure to affix the mounting template as described in the above chart , 
otherwise it can be dangerous since there may be no detection area around 
the threshold. Install the sensor as low as possible on the header.

WARNING

Danger of electric shock.

Do not use the sensor without the cover. 
When using the cable knockout, install the sensor indoors or use the rain-cover 
(Separately available) otherwise electric shock or breakdown of
 the sensor may occur. 

Before starting the procedure, make sure that the power is turned OFF.
When passing the cable through the hole, do not tear the shield.
otherwise it may cause electric shock or breakdown of the sensor.

To  the connector
of the sensor

4

Power supply

  12 to 24VAC±10% /12 to 30VDC±10%

Wire the cable to the door controller as shown below.

1.Plug the connector of the sensor.
2.Supply power to the sensor.  Adjust the detection area and set the dipswitches. (See 

ADJUSTMENTS

Place the housing cover.
If wiring is to be exposed, break the knockout.

}

H : Height from the floor to the bottom of the header
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
    (The mounting height is "H + Y".)

WARNING

Danger of electric shock.

NOTE

Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more 
than 10 seconds in order to enable the presence detection.
Do not touch the dipswitches before turning the power ON, otherwise an error occurs.
When changing the settings of dipswitch, see 

ADJUSTMENTS 3 Dipswitch settings

.

1.White
2.Brown

3.Green
4.Yellow

5.Pink (+)
6.Blue (-)

7.Red (+)
8.Black (-)

Safety / Test output

  Opto coupler(NPN) / Voltage: 5 to 50VDC

Activation output

  Form A relay 50V 0.3A Max.

Test input

  Opto coupler / Voltage: 5 to 30VDC

INSTALLATION

The following conditions are not suitable for sensor installation.
 -Fog or exhaust emission around the door.
 -Wet floor.
 -Vibrating header or mounting surface.
 -Moving objects or objects that emit light near the detection area. 
 -Highly reflecting floor or highly reflecting objects around the door.

 
 

NOTE

Detection area

Stand-by  (Setting mode)

 Blinking Blue

Stand-by  (Installation mode)

Stand-by  (Operation mode)

Green

Wrong dipswitch setting 

Red & Green blinking

Signal saturation

Slow Green blinking

Sensor failure

Fast Green blinking

Yellow

1st row detection

 Blinking Red

2nd row detection

3rd, 4th or 5th row detection 

Orange

Red 

1sec.

1sec.

Status

 Operation 

indicator

 color

1st row

2nd row
3rd row

4th row

5th row

: Emitting spots

: Detection Area

A

B

C

D

E

F

H

Motion / Presence

detection

Motion detection

: Emitting spots 
  (Can be eliminated)

Charts show the values in the following
depth angle adjustment settings ;

       1st to 3rd rows    : +6° 
       4th and 5th rows : +44°

[m(feet,inch)]

Emitting area

A
B
C
D
E
F

G
H

I (*)

X

1.35 (4' 5")

2.20 (7'2")
0.14 (6")
0.42 (1' 5")
0.82 (2' 8")

1.90 (6' 3")

1.33 (4' 4")
2.05 (6' 9")

2.78 (9' 2")

2.70 (8'10")
0.18 (7")
0.52 (1' 8")
1.00 (3' 3")
1.66 (5' 5")
2.34 (7' 8")

3.00 (9'10")
0.20 (8")
0.58 (1' 11")
1.10 (3' 7")
1.85 (6' 1")
2.60 (8' 6")

1.63 (5' 4")
2.51 (8' 3")

1.81 (5' 11")
2.79 (9' 2")

3.40 (11' 2")

3.79 (12' 5")

2.50 (8'2") 
0.16 (6")
0.48 (1' 7")
0.93 (3' 1")
1.54 (5' 1")
2.17 (7' 1")

1.51 (4' 11")
2.32 (7' 7")

3.15 (10' 4")

1.23 (4' 1")

2.00 (6'6")
0.13 (5")
0.38 (1' 3")
0.74 (2' 5")

1.74 (5' 9")

1.06 (3' 6")
1.86 (6' 1")

2.52 (8' 3")

0.21 (8")

0.26 (10")

0.28 (11")

0.24 (9")

0.19 (8")

X is the distance between the 1st row and the mounting surface.

A
C

G

I

2.20 (7'2")

2.00 (6'6")

0.24 (10")
1.10 (3' 7")
2.54 (8' 4")

0.23 (9")
1.02 (3' 4")
2.41 (7' 11")

The values above are when the sensitivity is set to "Middle" and speed of detection object is 50mm / sec..

Maximum mounting distance (Y)

X

H

Y

Sensor

Door

Header

Floor

X

2.00 (6' 6")

2.30 (7' 6")

2.50 (8' 2")

2.80 (9' 2")

0

No limit

0.05 (2")

0.20 (7")

0.20 (7")

0.20 (7")

0.10 (4")

0.20 (7")

0.20 (7")

0.20 (7")

0.20 (7")

0.15 (6")

0.13 (5”)

0.15 (5”)

0.19 (7")

0.20 (7")

0.20 (8")

-

0.12 (4”)

0.14 (5”)

0.15 (5”)

0.25 (10")

0.12 (4”)

0.30 (12")

-

-

H

0.20 (7")

-

-

-

-

0.11 (4")

[m (feet,inch)]

SPECIFICATION

(9)

(1)

(5)

(4)

(7)

(6)

(8)

(3)

(2)

Machinery Directive 2006/42/EC

Noise level

: <70dBA

3.00 (9'10")

0
0
0

0

0

-

1. Affix the mounting template at the desired mounting position.

2. Drill two mounting holes of ø3.4mm (ø1/8”).
3. To pass the cable through the header, drill a wiring hole of ø8mm (ø5/16”).
4. Remove the mounting template.
5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.

(When setting the detection area close to the door, mount the sensor according to the chart below.)

EN ISO 13849-1:2008

EN ISO 13849-2:2008

prEN 16005

EMC Directive 2004/108/EC