Страница 1: ...NG FO tely ther the nce use of peration Retain t Improper in service or property da and mainte installing o OR OUTDOO Installer m owner On should per n and S O these instru nstallation maintenanc amag...

Страница 2: ...2 APRIL 25 2013 SERIES DECO TUBE...

Страница 3: ...SPECIFICATIONS 10 CLEARANCE TO COMBUSTIBLES 11 HEATER MOUNTING 13 INSTALLATION INSTRUCTIONS 14 INSTALLATION SEQUENCE 14 STANDARD FREE HANGING INSTALLATION 14 DROP CEILING INSTALLATION 28 VENTING 31 G...

Страница 4: ...area of this heating appliance Playing or running around the structure should be strictly forbidden Clothing or other flammable materials should not be hung on or near this heater Any guard or other...

Страница 5: ...for either indoor or outdoor installation Not for use in residential dwellings refer to Rating plate Gas Supply Lines Gas supply pipe sizing must be in accordance with the National Fuel Gas Code ANSI...

Страница 6: ...k Washer QTY 4 Burner Hanger QTY 1 Middle Hanger Ass y QTY 1 Vent Hanger QTY 1 8 32 x 3 8 Screws QTY 42 Gasket QTY 1 Coupling QTY 1 Vent Terminal Assembly QTY 1 8 X 1 2 screws Self drilling QTY 2 Deco...

Страница 7: ...APRIL 25 2013 Specifications Heater Components continued 10 Flanged Tube QTY 1 4 Extension Tube QTY 1 Primary Reflector QTY 1 Secondary Reflector QTY 1 Deco Grille QTY 3 6 Baffle QTY 1 SERIES DECO TUB...

Страница 8: ...25 2013 Specifications Dimensional Details Note All dimensions are in inches 6 5 Electrical Cord Location 5 0 Gas inlet Location 9 1 Thermostat Connection 4 2 4 5 1 1 3 5 14 5 4 0 14 1 6 0 SERIES DEC...

Страница 9: ...9 APRIL 25 2013 Specifications Dimensional Details continued Note All dimensions are in inches 9 2 180 1 14 8 13 9 195 9 4 0 14 1 1 6 90 0 72 0 SERIES DECO TUBE...

Страница 10: ...ded 3 prong plug Important Installation or repair should only be done by a qualified service person The heater should be inspected before use and at least annually by a qualified service person The ap...

Страница 11: ...lexiglas or other materials capable of being ignited and burned Such materials shall be considered combustible even though flame proofed fire retardant treated or plastered Adequate clearance to sprin...

Страница 12: ...A B C D 8 2 5 55 5 43 Ends both sides 4 This heater can be installed between wood beams with minimum distances as shown Air flow MUST NOT d e t c i r t s e r e b NOTE Some materials deteriorate or so...

Страница 13: ...and turnbuckles Other methods such as chain and appropriate bracing can be incorporated as an alternative The heater must be prevented from swaying and putting stress on the gas connection The install...

Страница 14: ...llation is begun at the most critical dimension watching for interference from overhead beams etc It is RECOMMENDED to follow the installation sequence shown in the following pages Standard FREE Hangi...

Страница 15: ...15 APRIL 25 2013 Installation Instructions Step 2 Step 3 90 0 60 0 Pipe stand Pipe stand Flanged tube SERIES DECO TUBE...

Страница 16: ...16 APRIL 25 2013 Installation Instructions Step 4 Step 5 Burner hanger Middle hanger assembly Burner hanger SERIES DECO TUBE...

Страница 17: ...17 APRIL 25 2013 Installation Instructions Step 6 Step 7 Middle hanger assembly Burner hanger Coupling SERIES DECO TUBE...

Страница 18: ...lation Instructions Step 8 Step 9 When installing orient band clamp lock bolts to side at 3 o clock or 9 o clock position to avoid contact with reflector Torque to 15 25 ft lbs 4 Extension tube Vent h...

Страница 19: ...19 APRIL 25 2013 Installation Instructions Step 10 Step 11 Primary Reflector SERIES DECO TUBE...

Страница 20: ...20 APRIL 25 2013 Installation Instructions Step 12 Step 13 Slide reflector and hanger against flange 8 32 X 3 8 screws SERIES DECO TUBE...

Страница 21: ...p 14 Step 15 Bend tab over end of tube at 6 o clock position Baffle Vent terminal assembly 8 X 1 2 self drilling screws Push vent terminal assembly over baffle tab Secure vent terminal assembly to tub...

Страница 22: ...22 APRIL 25 2013 Installation Instructions Step 16 Step 17 Secondary Reflector 8 32 X 3 8 screws SERIES DECO TUBE...

Страница 23: ...23 APRIL 25 2013 Installation Instructions Step 18 Use turnbuckles or angle iron to secure heater into angle irons anchored to ceiling SERIES DECO TUBE...

Страница 24: ...2013 Installation Instructions Step 19 Step 20 Gasket Heater Burner Use 5 16 washers and nuts to attach burner to flanged tube Use turnbuckle to secure heater to ceiling angle iron Deco Grille SERIES...

Страница 25: ...25 APRIL 25 2013 Installation Instructions Step 21 Step 22 Deco grille supports clip 8 32 X 3 8 screws Deco grille support SERIES DECO TUBE...

Страница 26: ...26 APRIL 25 2013 Installation Instructions Step 23 Step 24 2nd Deco Grille A B 3rd Deco Grille Install deco grille support first 8 32 X 3 8 screws SERIES DECO TUBE...

Страница 27: ...27 APRIL 25 2013 Installation Instructions Step 25 Step 26 End cap 8 32 X 3 8 screws SERIES DECO TUBE...

Страница 28: ...2013 Installation Instructions Drop Ceiling Installation Continue on from step 19 Drop ceiling installation WITH metal border Min 3 0 Max 11 0 Metal border Deco grille Metal border Deco grille SERIES...

Страница 29: ...stallation continued Drop ceiling installation WITH REFLECTOR Shield No Metal Border Ceiling Tiles Deco Grille Reflector shield cut to fit deco grille sections Min 3 0 Max 5 75 Ceiling Tiles Reflector...

Страница 30: ...on Instructions Deco Grille Installation continued Drop ceiling installation WITHOUT REFLECTOR Shield No Metal Border Non Combustible Ceiling Tiles Deco grille Non Combustible Ceiling Tiles Min 3 0 De...

Страница 31: ...DOOR INSTALLATION ONLY WARNING This heater is NOT approved for any indoor Residential application If in doubt of your application consult with your local fire marshal or gas authority having jurisdict...

Страница 32: ...I NFPA 70 in the USA CSA C22 1 Canadian Electrical Code in Canada Check for gas leaks at all connections with appropriate soap solution Never connect an unregulated gas supply to the heater Do not use...

Страница 33: ...must be replaced with wiring having a rating of at least 105 C temperature service and 600 volts capability NOTE If any of the original wire as supplied with the appliance must be replaced it must be...

Страница 34: ...ENSOR 24V BLOWER Green Pink Black Yellow Black Yellow Blue SWITCH AIR Red Brown L1 TRANSFORMER NEUTRAL 120V Brown Yellow Blue Green Green Pink Black R1 R1 MOUNTED EXTERNALLY W1 STAT R W2 THERMOSTAT IS...

Страница 35: ...Grounded Supply Ensure A Good Ground Source Manual Line Switch with Hi LO wiring diagram Two Stage Switch wiring diagram 24 Volt AC Supply 24 Volt Transformer Ensure A Good Ground Source 115 VAC Groun...

Страница 36: ...ains open The sparking stops when the flame signal is established 7 If no flame is detected the gas valve closes and a 30 sec inter purge period begins After the inter purge the module repeats the tri...

Страница 37: ...other than routine maintenance Be sure vent terminal and fresh air inlet are free from obstructions If either pipe is restricted the safety air switch will not operate properly and the heater could f...

Страница 38: ...vice person are required Check to see if gas lines were properly purged of air Check inlet and outlet gas pressure during ignition period Check for proper orifice and air plate Burner Does Not Stay Li...

Страница 39: ...tor Impeller Spin Freely IF PROBLEM PERSISTS CONTACT YOUR LOCAL IR ENERGY REPRESENTATIVE Verify Sense Electrode Verify Ground Verify Wiring Does 24V Occur At Valve During Ignition Trial Check Wiring a...

Страница 40: ...NAT CG308 BLOWER MOTOR CE004 BLOWER GASKET CH007 6 FLAME SENSOR ELECTRODE CE003 14 ITEM PART DESCRIPTION 9 BURNER CUP BURNER CUP ASSEMBLY C W ELECTRODES UG001P UG007 SIGHT GLASS ASSEMBLY CH011 10 CE0...