background image

 

Page 13 von 23 

26.08.2014

 

Ver. 1.9 

 

Copyright Berner Kochsysteme 2015

 

Attention 

Don’t open the unit! 

Dangerous voltage! 

 

Troubleshooting 

WARNUNG: During cleaning or maintenance and replacement of parts of the equipment must 

be disconnected from the power supply. 

 

With all faults of the unit, which are not due to external 

influences or dirt, only approved specially trained 

service Employee  should open the unit.  Turn OFF the 

unit immediately and disconnect the unit from the main 

supply.  The cause analysis or debugging must be done 

by qualified personnel. 

 

Possible faults 

Fault 

Possible cause 

Troubleshooting by User or Service staff 

No heating up 

operation indication 

lamp is OFF 

No current supply 

Control, if the unit is connected to the power 

supply (Power cable connected?), Main 

switch is in Off Position, check fuses. 

No heating up 

Safety thermostat 

(STB) „capillary tube 

to close on the basin”. 

If the safety thermostat switches the unit of, 

the reason is a high temperature 

/continuous load. On constant switching off 

can be detected a defect. 

Marking: 

The feeler is placed 

on the heating 

element. 

The safety thermostat switches also if the 

ambient temperature drops under 0

°

C. On 

some local places for example in mobile 

shops. Heat up the room to a normal 

temperature 20

°

C before you quit the fault 

on the safety thermostat. 

Temperature 

controller in Off-

position 

Turn temperature controller in ON-Position 

Insufficient heating or 

no heating on. 

Operation indication 

lamp is ON 

Single phase missing  Check the fuses. 

 

Heating element 

broken! 

Contact your dealer for the repair service. 

Disconnect the unit from the power supply. 

Deep fryer broken 

No reaction by 

changing the value  

with the knob 

Temperature 

controller broken 

Heating up turn on and 

off within minutes. 
No reaction by 

changing the value  

with the knob 

Red Lamp lights 

Heating element not in position 

 

Overview of possible messages in the display 

If the unit have a technical problem, the display shows a message. 

 

 

Over temperature or missing feeler value PT1000 (interruption) 

 

 

 

Short circuit feeler PT1000 or temperature value to low < -40°C 

 

 

In case of replacing parts use only original parts according to the valid parts list, use the 

existing or new replacement parts with the same fasteners. This also applies to the assembly 

of outer housing parts, such as the bottom plate after a change of the power cord. 

 

 

Содержание BFEE20

Страница 1: ...EE60 2 options EOH ESB BFEM1H BFEM2H BEPSF1 BEPSF2 Read the instructions for use and installation instructions before to start the installation build in commissioning Thereby protecting yourself and a...

Страница 2: ...cal data of the units 7 Unit performance 7 5 kW BFEM20 BFEE20 7 Unit performance 12 0 kW BFEM30 BFEE30 7 Unit performance 16 5 kW BFEM40 BFEE40 7 Unit performance 15 0 kW BFEM40 2 BFEE40 2 7 Unit perf...

Страница 3: ...eriod 15 Declaration of conformity 16 Spare Parts List 17 Technical documentation 19 Instrument view Example BFEM50 2 19 Installation example 19 Installation instructions to build in of an Berner 20 S...

Страница 4: ...e deep fryer is working but the display doesn t work Switch off the fuse or disconnect the unit from the main supply Call your customer service Objects made of metal get very quickly hot in the basin...

Страница 5: ...e the safety thermostat switch the unit off after a short time By entering of large amounts and to wet food to be fried the foaming of the oil is enhanced Never fight oil or grease fire with water ris...

Страница 6: ...kept close to the cooking site for reference Application The deep fryer is designed to deep fry food Product description Products BFEM20 BFEM30 BFEM40 BFEM40 2 BFEM50 2 BFEM60 2 BFEE20 BFEE30 BFEE40...

Страница 7: ...PE 5 10 Connection Colour Frequency Fuse Phase brown black grey or 1 2 3 50 Hz 60 Hz B6 F1 T1A F2 N blue or 4 PE yellow green Unit performance 15 0 kW BFEM40 2 BFEE40 2 3 phase Voltage 400V 3 N PE 5 1...

Страница 8: ...supply The installation must be tested for practicality Don t install set up or install near sources of water Don t install the unit on the same level with the surface Don t install the unit in near...

Страница 9: ...en furniture decorative panels etc is recommended that these are not made of flammable material otherwise they must be covered with suitable non combustible heat insulating material and the fire safet...

Страница 10: ...on the right side of the symbol Target temperature 110 C Point real temperature in range 2 C No heating Real temperature 115 C real temperature to high No heating Cooking process Fill the basin with...

Страница 11: ...imer starts to count In this range of time you can cancel the countdown with the button the basket moves to the start position After a regular countdown the basket moves automatically back to the star...

Страница 12: ...el control of the grease Don t exceed or below this level when you fill the oil in the basin During frying fat level must not fall below the minimum marker A low level can lead to inflammation of the...

Страница 13: ...ing element The safety thermostat switches also if the ambient temperature drops under 0 C On some local places for example in mobile shops Heat up the room to a normal temperature 20 C before you qui...

Страница 14: ...run Disregard any warranty claim is rejected Remove remains of cleaning agents with a damp cloth Scotch because they have a corrosive effect An expert maintenance of the equipment requires regular cl...

Страница 15: ...ched to the end of the service life it must be disposed of correctly Avoid misuse The equipment can t be used by someone who is not qualified to do Make sure that the unit you want to dispose of can t...

Страница 16: ...0 EU The conformity of the designated product with the provisions of Directives 2014 30 EU and 2014 35 EU is evidenced by full compliance with the following standards This declaration does not guarant...

Страница 17: ...Page 17 von 23 26 08 2014 Ver 1 9 Copyright Berner Kochsysteme 2015 Spare Parts List...

Страница 18: ...Page 18 von 23 26 08 2014 Ver 1 9 Copyright Berner Kochsysteme 2015...

Страница 19: ...19 von 23 26 08 2014 Ver 1 9 Copyright Berner Kochsysteme 2015 Technical documentation Instrument view Example BFEM50 2 Installation example Stainless steel cover Backslash approx 15 mm Place the dev...

Страница 20: ...ctronic with frame Ver A Frame inclusive electronic is pre assembled with glued glass ceramic Please observe the following installation instructions The only way to ensure a trouble free operation and...

Страница 21: ...ctronic with frame Ver A2 Frame inclusive electronic is pre assembled with glued glass ceramic Please observe the following installation instructions The only way to ensure a trouble free operation an...

Страница 22: ...th frame Ver B Frame inclusive electronic is pre assembled with glued glass ceramic 2 3 mm standing out Please observe the following installation instructions The only way to ensure a trouble free ope...

Страница 23: ...http sdrv ms MjWZYA BEBSF1 http 1drv ms 1g6NN26 BEBSF2 http 1drv ms 1g6NX9v Attention Link to the matching installation drawings Please copy the link in your internet browser This link leads you to th...

Отзывы: