background image

   

 

Version 1.3

 

Page 1 of 20 

13.01.2016 

 

Istruzione per l’uso e la manutenzione - CUCINE GAS 
Instructions for installation and use - GAS COOKERS 
Gebrauchs-und Installationsanleitung - GASHERDE 
Notice d'emploi et de maintenance - CUISINIERES A GAZ 
Instrucciones para el uso y mantenimiento - COCINAS A GAS 

 

Targhetta tecnica – Technical data plate – Typenschild – Plaque technique – Placa del fabricante 

 

 

 

 

 

 

Содержание 206001

Страница 1: ...tructions for installation and use GAS COOKERS Gebrauchs und Installationsanleitung GASHERDE Notice d emploi et de maintenance CUISINIERES A GAZ Instrucciones para el uso y mantenimiento COCINAS A GAS...

Страница 2: ...t of the nozzles 10 7 1 Adjustment of the burner nozzle 11 12 7 2 Fine tune of the gas flame 13 7 3 Adjustment of the pilot burner nozzle 14 8 Technical data of the units 15 9 Technical data of the un...

Страница 3: ...as supplying company before installation of the unit confronting and respecting the technical data plate with the local conditions The built in operations eventual adjustments and the maintenance of t...

Страница 4: ...gen environment air The installation room must not be modified after installation of the gas unit Never ignite the gas unit if there is a strong gas smell in the air open wide windows and doors to cha...

Страница 5: ...to the mains through authorised and trained personnel following and respecting the rules and regulations stated in the relative user manual Every electric appliance must have a separate and adequately...

Страница 6: ...rners and close the main gas tap Please allow some time to let the unit cool down otherwise the detergent could stick to the burner or burner cover Never cool down the unit through a water hose or hig...

Страница 7: ...e burner taps and ignite the burners The pressure must comply with the indicated values of the following table After the gas pressure test the unit can be taken into function At the first ignition aft...

Страница 8: ...ough a lit match or other ignition means As soon as the pilot flame is lit keep the knob pushed for some seconds in order to let the pilot thermocouple warm itself and keep up the pilot flame Image De...

Страница 9: ...ailable only authorised trained and licensed personnel can substitute the nozzles installed by the OEM The exact gas type the unit is set with is indicated on the technical data plate placed near the...

Страница 10: ...better Hotplate clatters is unstable Hotplate not positioned correctly Check positioning never on burner type E with 7 5 kW Pilot flame cover doesn t fit Wrong positioning The cover has one direction...

Страница 11: ...and check the primary air distance Then close the stud screws The following table shows the nozzle diameter and primary air distance Nozzle burner C Distance A Nozzle burner D Distance A Nozzle burner...

Страница 12: ...1 3 Page 12 of 20 13 01 2016 Image Description Nozzle holder Nozzle Venturi tube for burner C Venturi tube for burners D and E Flexible connection tube Detail primary air distance A in mm follows Dis...

Страница 13: ...r each burner Ignite the relative burner and fine tune the flame on low power with a small screwdriver If the burner is connected to a propane gas line the screw must be tightened Image Description Fi...

Страница 14: ...in place the hex screw and tighten it Insert and fix the pilot burner on the unit again Below the table of the pilot burner nozzles Burner C Burner D Burner E Natural gas H E E G20 20 mbar of a turn 2...

Страница 15: ...850 1 1 BHG4P70 800 700 Min 850 2 2 BHG4P70B 800 700 Min 850 2 2 BHG6P70 1200 700 Min 850 2 2 2 BHG6P70B 1200 700 Min 850 2 2 2 BHG2S85 400 850 Min 850 1 1 BHG4S85 800 850 Min 850 1 2 1 BHG4S85B 800 8...

Страница 16: ...00 700 Min 850 3 3 207004 800 700 Min 850 2 2 207006 1200 700 Min 850 3 3 208000 400 850 Min 850 1 1 208001 800 850 Min 850 1 2 1 208003 1200 850 Min 850 1 2 3 208002 400 850 Min 850 1 2 1 208004 1200...

Страница 17: ...atural gas G20 G25 m h Propane G30 G31 Kg h Burner C 0 370 0 431 0 272 0 276 Burner D 0 582 0 677 0 427 0 434 Burner E 0 794 0 923 0 583 0 591 10 Technical data of the units Gas categories Country Pre...

Страница 18: ...r The pilot burners are supplied with a protection cover made of stainless steel to ensure the cleanliness of the thermocouple During operation of the unit keep the cover in place and clean it if nece...

Страница 19: ...very hot please be careful Do not cool it down after use with a water tap or ice as it may bend or warp Only clean if cold or warm with soapy water and a soft cloth never use harsh detergents or abra...

Страница 20: ...ty opening to avoid overflowing of the trough and penetration of liquids through the burner into the gas circuit Should this accidentally happen please close the main gas tap and contact your retailer...