7.5 MUT2770
7.5.1 Dimensions and main features
The MUT2770 sensor is suitable for fixed installation in medium-large diameter pipes. It can be supplied in
different sizes depending on the size of the pipe in which it will be installed, starting from a minimum of DN100
up to DN2500.
The installation and assembly/disassembly of this meter requires a 50mm hole drilling on the pipe and a flanged
sleeve welding.
ATTENTION: For installation, assembly, and disassembly of the meter, the pipe must be empty - the sensor does
not have Hot-Tap functionality.
The maximum pressure at which the meter can operate is 25bar.
NOTE: The supply of the flowmeter includes a flanged sleeve that has to be installed on the pipe after cutting
it to the right size.
Size
DN Range
L
Li
Ld
A
100…500
251
115
115
B
600…1100
321
185
115
C
1200…1600
400
264
115
D
1700…2100
466
330
115
E
2200…2500
555
419
141
Mounting sleeve
Sf
Ld
2xM10x1.5
Ø 104
Ø 47
C
C
63
74
Dp
4xDf
De
13
6
Li
Sf
L
SECTION C-C
Flange
Grounding
Messa a terra
Flange dimensions
UNI - EN1092
ANSI150
Dp
110
98.4
De
150
125
Df
18
16
Sf
18
20
Fig. 85