Страница 1: ...BIC F M 0 7 30 20 FLUSH MODE DP ACTUAL DP SET BAR Min Sec FLUSH TIME BIC F Modular Backflushing Controller BERMAD Irrigation Control System Operation Manual...

Страница 2: ...4 3 Description of Editable Fields 5 4 Configuration Process 6 5 Handling Endless Looping Problems 7 6 Handling Low Pressure 8 7 Connecting the DP Sensor to the Filter System 8 8 Low Battery 8 9 Manu...

Страница 3: ...tch and time back up Continuous back flush loops detection Eliminates continuous cycles of back flush caused by filtration failure Manage Pressure Sustaining or Main Valve Conserve energy by holding b...

Страница 4: ...1 Push the ENTER key The first editable field blinks and is active 2 Use the and keys to change the value 3 Push the ENTER key again to set the new value The next editable field blinks and is active 4...

Страница 5: ...s of 5 seconds 1 6 minutes in steps of 0 5 minute DP Set Point Defines the pressure difference between the filter s inlet and outlet When reached a flushing cycle initiates This field appears only whe...

Страница 6: ...ts are used in the system Configuration Process Definitions During the configuration process the following features are defined Main Valve sustaining valve Yes No When the answer is Yes the Pre Dwell...

Страница 7: ...e measurement Select between BAR or PSI Calibration Zero calibration of the built in electronic DP sensor While the sensor ports are disconnected select Calibration Yes 5 Handling Endless Looping Prob...

Страница 8: ...the one that comes from the outlet lower pressure is connected to the black fitting IMPORTANT A small 120 mesh filter must be installed between the red fitting and the high pressure connection point...

Страница 9: ...agram Without Delay Valve Including Delay Valve Main valve Valve 1 Valve 2 Pre Dwell Flush time Valve 3 Valve 4 Dwell time Main valve Valve 1 Valve 2 Pre Dwell Flush time Valve 3 Valve 4 Delay valve D...

Страница 10: ...e when there is no Embedded Electronic DP included The unit can be powered either by 6V DC or 12V DC The solenoids are 12VDC latch Out A Out B C Out A Out B C Out A Out B C Out A Out B C Out A Out B C...

Страница 11: ...is no Embedded Electronic DP included The unit is powered by 24VAC transformed from 220 110 VAC The solenoids are 24VAC 110 v 220 v Built in Power Supply Energy Source 220v AC 50 Hz or 110v AC 60 Hz...

Страница 12: ...e of the following Embedded electronic analog DP sensor External dry contact DP sensor Pressure sensor Dry contact pressure sensor operating temperature 0 60 C AC MoDEL Power source 220V or 110V AC 50...

Страница 13: ...BERMAD Water Control Solutions Copyright 2007 2012 Bermad CS Ltd All Rights Reserved The information contained in this document is subject to change without notice BERMAD shall not be liable for any e...