background image

BDBSL

Slim Line Draft Barrier 

Convection Heaters

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO
PERSONS, INCLUDING THE FOLLOWING:

1. Read all instructions before installing or using the heater.

2. A heater has hot and arcing or sparking parts inside.  Do not

use in areas where gasoline or flammable liquids are used
or stored.

3. This heater is hot when in use.  To avoid burns, do not let

bare skin touch hot surfaces.  Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, and cur-
tains away from heater.

4. To  prevent  a  possible  fire,  do  not  block  air  intakes  or

exhaust in any manner.

5. Do not insert or allow foreign objects to enter any ventilation

or exhaust opening as this may cause an electric shock or
fire, or damage the heater.

6. Serious  injury  or  death  could  result  from  electric  shock.

Make sure electrical power supply circuit coming to heater
is disconnected at main disconnect or service panel before
installing or servicing this heater.

7. BDBSL model with 188 watts per linear foot or less, without

wire mesh, are ETL listed for residential use. 

8. BDBSL model at 188 watts per linear foot must be mounted

above finished floor with a clearance of 2 inches.

SAVE THESE INSTRUCTIONS

!

WARNING

Dimensions

Type

Height

Width

Length

BDBSL

4”

2-5/8”

24” to 12’

152mm

69mm

610mm to 3658mm

Installation, Operation & Maintenance Instructions

IMPORTANT INSTRUCTIONS

GENERAL

This heater is designed to provide years of efficient, trouble free operation as a primary or supplemental heat source for comfort
heating in residential and commercial applications. Installation or use of this product in any manner not described within this manual
will void the warranty and could result in injury, damage to property, or permanent damage to heater.

Содержание BDBSL

Страница 1: ...or damage the heater 6 Serious injury or death could result from electric shock Make sure electrical power supply circuit coming to heater is disconnected at main disconnect or service panel before i...

Страница 2: ...1 6 1 4 02100 100 200 1 7 1 0 0 8 02125 28 125 250 2 1 1 2 1 0 0 9 02150 711mm 150 300 2 5 1 4 1 3 1 1 02188 188 376 3 1 1 8 1 6 1 4 03100 100 300 2 5 1 4 1 3 1 1 03125 3 125 375 3 1 1 8 1 6 1 4 1 1...

Страница 3: ...SK OF FIRE AND ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Serious injury or death could result from electric shock Make sure electrical power supply circuit coming to heater are disco...

Страница 4: ...splice kits or end caps are to be used consult convector accessory instal lation instructions If units are to be pedestal mounted con sult the convector accessories installation instructions NOTE If a...

Страница 5: ...f heater continues to cycle on this safety control discontinue using until it can be inspected and or repaired by a qualified electrician MAINTENANCE INSTRUCTIONS Your heater will give your years of s...

Страница 6: ...NTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR...

Страница 7: ...rica incendio o podr a da ar el calefactor 6 Podr an producirse lesiones graves o la muerte por descar ga el ctrica Antes de instalar o suministrar servicio de mantenimiento a este calefactor verifiqu...

Страница 8: ...ngitud Watts Watts Amperaje cat logo L por pie total 120 V 208 V 240 V 277 V 347 V 600 V 22100 100 200 1 0 22150 24 150 300 2 5 1 4 1 3 22188 610 mm 188 376 3 1 1 8 1 6 1 4 02100 100 200 1 7 1 0 0 8 0...

Страница 9: ...n se requiera a todo lo largo del calefactor hasta que la cubierta delantera se desenganche comple tamente de la parte trasera del calefactor PARA REDUCIR EL RIESGO DE INCENDIO Y DESCARGA EL C TRICA O...

Страница 10: ...ulte las instruc ciones de instalaci n de los accesorios del calefactor de convecci n Si las unidades deben montarse en pedestal consulte las instruc ciones de instalaci n de los accesorios del calefa...

Страница 11: ...control de seguridad interrumpa su uso hasta que pueda ser inspeccionado y o reparado por un electricista capacitado INSTRUCCIONES DE MANTENIMIENTO Su calefactor le proporcionar a os de servicio y com...

Страница 12: ...O Y EXCLUIDAS DE ESTE ACUERDO MARLEY ENGINEERED PRODUCTS NO SER RESPONSABLE POR DA OS CONSECUENCIALES QUE SURJAN CON RESPECTO AL PRODUCTO EST N O NO BASADOS EN NEGLIGENCIA INFRACCI N RESPONSABILIDAD E...

Страница 13: ...ctrique ou un d part d incendie ou endommager le radiateur 6 Une blessure s rieuse voire mortelle peut r sulter d une commotion lectrique Assurez vous que le circuit du secteur d alimentation lectriqu...

Страница 14: ...22100 100 200 1 0 22150 24 150 300 2 5 1 4 1 3 22188 610 mm 188 376 3 1 1 8 1 6 1 4 02100 100 200 1 7 1 0 0 8 02125 28 125 250 2 1 1 2 1 0 0 9 02150 711 mm 150 300 2 5 1 4 1 3 1 1 02188 188 376 3 1 1...

Страница 15: ...vercle hors du carter arri re du radiateur POUR R DUIRE LE RISQUE DE D PART D INCENDIE DE COM MOTION LECTRIQUE ET DE BLESSURES AUX PERSONNES OBSERVEZ LES CONSIGNES SUIVANTES 1 Une blessure s rieuse vo...

Страница 16: ...s s consultez les instructions d installation de ces accessoires Si le radia teur est mont sur socle consultez les instructions d installation d ac cessoires du convecteur REMARQUE Si un radiateur com...

Страница 17: ...cessez de l utiliser avant qu il ait t inspect et ou r par par un lectricien qualifi INSTRUCTIONS D ENTRETIEN Votre radiateur vous fournira des ann es de bon service et de confort avec juste un minimu...

Страница 18: ...EXCLUES DE CET ACCORD MARLEY ENGINEERED PRODUCTS NE SERA PAS TENU POUR RESPON SABLE DES DOMMAGES CONS CUTIFS SURVENANT EN RELATION AVEC LE PRODUIT QU ILS SOIENT BASE DE N GLIGENCE TORT RESPONSABILIT P...

Отзывы: