Страница 1: ...USER HANDBOOK 1 0 ET2115 Ethernet Terminal ...

Страница 2: ... other countries EtherCAT is a registered trademark and patented technology licensed from Beckhoff Automation GmbH Germany CiA and CANopen are registered trademarks belonging to CAN in Automation e V ARM and Cortex are registered trademarks belonging to ARM Limited PROFINET is a registered trademark belonging to PROFIBUS Nutzerorganisation e V Modbus is a registered trademark belonging to the Modb...

Страница 3: ... Harretstrasse 1 72800 Eningen www berghof com 21 0099 82 00 00 003 222002100_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 3 Change log Version Date Description 0 8 24 06 2015 Draft 0 9 02 07 2015 Preliminary version 1 0 09 02 2016 First version ...

Страница 4: ... 1 Safety instructions 10 3 PRODUCT DESCRIPTION 11 3 1 Overview 12 3 2 Scope of delivery and accessories 13 3 3 Product features 13 4 INSTALLATION 14 4 1 Preparation for installation 14 4 2 Installation 16 5 CONNECTION 18 5 1 Power supply 18 5 1 1 Connecting the power supply 19 5 2 Data connections 20 5 2 1 Block circuit diagram 20 5 2 2 Ethernet 21 5 2 3 USB 22 6 OPERATION 23 6 1 Switching on and...

Страница 5: ...ance of the touch screen 31 7 3 2 Resistance of the front diaphragm 32 8 UNINSTALLATION 35 8 1 Uninstallation 35 9 DISPOSAL 37 10 TECHNICAL DATA 38 10 1 Identification plate 40 10 2 Identification 41 11 STANDARDS AND CERTIFICATES 42 11 1 Standards 42 11 2 UL certificate 43 11 3 Declaration of conformity 45 11 4 Information on copyright and software licence 46 12 CUSTOMER SERVICES ADDRESSES 47 12 1...

Страница 6: ...nt of the product and applies to the Ethernet Terminal ET2115 It contains information on the following topics Applications Safety Mechanical design Electrical design Connections Start up Upkeep and maintenance Decommissioning Disposal Always keep this user handbook available alongside the product 1 2 Symbols and visual depictions The following symbols and visual depictions will be used in this han...

Страница 7: ...ble serious injury or death Non compliance with the safety features may result in death or serious injury Take preventive measures CAUTION Possible minor injuries Non compliance with the safety features may result in minor injuries Take preventive measures NOTE Possible damage to property Non compliance with the safety features may result in damage to property Take preventive measures Further info...

Страница 8: ...eration 1 6 Intended use The device is part of a modular automation system for industrial control applications within the medium to high performance range The automation system is designed for use within overvoltage category I IEC 364 4 443 systems for controlling and regulating machinery and industrial processes in low voltage installations in accordance with the following general parameters maxi...

Страница 9: ...s been stored or transported in cold weather or under conditions or large fluctuations in temperature do not start to operate it until it has acclimatised to room temperature for the place it is used If condensation is present wait at least 12 hours before starting to operate the device 1 8 Unpacking Or receipt of the device a check must be made that it is complete and undamaged 1 Check the packag...

Страница 10: ...ur All types of failure must be considered at the system level and the associated preventative measures identified If necessary request information from your automation system provider 2 1 Safety instructions The device may be operated only when it is in good working order Exposed sharp edges pose an injury risk If you discover damage to the front glass of the device do not continue to operate the...

Страница 11: ...t environment from 3S Smart Software Solutions is used for programming the device The Ethernet Terminal is specially configured for CODESYS visualisation and operation in machines and systems The terminal shows the CODESYS Web visualisation or CODESYS Target visualisation irrespective of whether the visualisation originates from a Berghof PLC control unit or some other CODESYS control unit The Eth...

Страница 12: ...w Fig 1 Overview ET2115 rear view Item Designation Item Designation 1 Display 15 6 inch X100 Power supply 2 Earth connection S1 Function button do not use this it is for use only by Berghof Service Engineers X3 USB 2 0 LED LEDs PWR Run Stop Error X4 Ethernet ETH0 µSD MicroSD card slot for future applications X8 Debug interface do not use this it is for use only by Berghof Service Engineers ...

Страница 13: ...h an 800 MHz ARM CPU with a Cortex A9 core Ethernet The device has two 10 100 Mbit s Ethernet interfaces The Ethernet interface is used for standard Ethernet connections TCP IP and UDP IP protocols permit flexible connections to visualisation software higher level control units and to the IT infrastructure USB The USB host interface allows a wide range of peripherals to be connected to the device ...

Страница 14: ...s To allow sufficient air circulation it must be ensured that the device has a clear space of at least 20 mm all round at the rear The max ambient temperature inside the control cabinet must not exceed 55 C in operation The support material for the installation cut out must be flat sufficiently stable and be from 1 to 4 mm thick NOTE Damage to the device Installation on uneven support material can...

Страница 15: ...om 21 0099 82 00 00 003 222002100_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 15 Fig 3 Installation cut out Cut a rectangular installation cut out in the support material Height 260 mm Width 402 mm Max corner radius 3 0 mm Thickness of the support material Optimally 2 0 3 0 mm Max 4 0 mm ...

Страница 16: ... the installation cut out Requirements The securing clips must not be attached to the device 1 Making sure the alignment is correct push the device evenly into the installation cut out NOTE Damage to the device If installation is performed carelessly the device can fall out of the installation cut out or be damaged Do not tilt the device Restrain the device against falling until the securing clips...

Страница 17: ...T2115_EN docx 17 2 Make sure the device lies flush all round Fig 5 Inserting the securing clips rear view 3 Secure the device with 2 securing clips Insert the securing clips into the cover at diagonally opposite points and tighten the screws finger tight Fig 6 Tightening the securing clips 4 Insert the remaining 6 securing clips and tighten all 8 screws equally ...

Страница 18: ...gned to be connected to a DC mains supply Before plugging in the device ensure that the external power supply meets the required specifications type K to 61131 2 External power supply 24 V DC Supply voltage 24 V DC SELV 15 20 Ripple current proportion Max 5 The direct voltage level must not fall below 20 4 V Power consumption Total max 0 6 A at 24 V DC peak current 1 2 A Internal power supply A po...

Страница 19: ...rk on the device switch off all power feeds including peripherals Connect the power supply to plug X100 according to the following table Fig 7 Power supply plug X100 Power supply plug X100 Pin Designat ion Assignment 9 L0 24 V Power supply 24 V DC 15 20 max 0 6 A peak current 1 2 A 11 GND M0 GND The following counterparts have been tested for the SC SMT 3 5 Weidmüller plug in connector and are app...

Страница 20: ...rghof Automation GmbH Harretstrasse 1 72800 Eningen www berghof com 21 0099 82 00 00 003 222002100_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 20 5 2 Data connections 5 2 1 Block circuit diagram Fig 8 Block circuit diagram ...

Страница 21: ...t adapter has one 10 100 Base T RJ 45 port for connection to the network Fig 9 Ethernet interface X4 Assignment of Ethernet interface plug X4 Pin Assignment Pin Assignment 1 TX 5 NC 2 TX 6 RX 3 RX 7 NC 4 NC 8 NC LEDs LED Colour Meaning to IEEE 802 3 clause 25 LNK RCV yellow Link Data Receive Flashing connection active data transfer in progress Off no connection established SPEED green On 100 Mbit ...

Страница 22: ...ender the USB stick unusable Open files which cannot be accessed due to removal of the USB stick can block the device Therefore ensure that all operations are complete before removing the USB stick NOTE Damage to property and malfunctions due to data loss The USB interface is protected against overloading 0 5 A In the event of a short circuit during operation the control unit may trigger a reset o...

Страница 23: ...y work on the device switch off all power feeds including those to any connected peripherals sensors and programmable devices etc with independent power supplies NOTE Damage to property Before connecting the power supply ensure that all cabling and the polarity of all the connections are correct Switching on The device does not have an on off switch The device starts automatically when the system ...

Страница 24: ...h the correct settings before it can be used NOTE Damage to property Before connecting the power supply ensure that all cabling and the polarity of all the connections are correct 1 Supply the device with power 24 V After the start the current network settings are displayed server IP IP address and network mask Fig 11 Start page with network settings 2 Press the Configuration button A page with fu...

Страница 25: ...n The page with the network settings of the device appears Fig 13 Network settings of the device 4 If necessary press the Edit button and change the network settings as required IP address network mask gateway 5 Press the Next button The page with the settings for the server IP and Lifeguard appears Fig 14 Setting the server IP 6 If necessary press the Edit button and change the server IP as requi...

Страница 26: ...ding on the controller version press the Change button to change the Lifeguard setting CODESYS V2 Berghof VNC LG CODESYS V3 Ping LG 9 Press the Next button to skip the following pages with until the page with the summary of the network settings appears Fig 16 Summary of the network settings 10 If no settings were changed press OK The main screen of the device will appear or Press the Save button T...

Страница 27: ...nd any error messages Location of the operating status LEDs The Run Stop and Error LEDs display the system status Fig 17 Location of the operating status LEDs LED Meaning 1 PWR green shows that the power supply to the electronics is correct 2 Run Stop yellow green re d shows the system statuses 3 Error red shows the device has been stopped due to an error Meaning of the LED displays System statuse...

Страница 28: ...jury as a result of uncontrolled and unpredictable operational behaviour Inserting or removing the microSD card can result in the device malfunctioning Failure in electronic control systems may result in uncontrolled and unpredictable operational behaviour Insert or remove a microSD card only when the device is switched off NOTE Loss of data microSD cards do not have their own write protection sys...

Страница 29: ...et Terminal ET2115_EN docx 29 6 4 Troubleshooting 6 4 1 No network connection Check the cabling switch Check whether an IP address has been duplicated Check the network settings on the PC The subnet and the subnet mask settings must be the same as those for the controller Check the firewall anti virus programs on the PC Check the Lifeguard settings ...

Страница 30: ...haviour Failures or malfunctions may result in uncontrolled and unpredictable operational behaviour Do not insert connect undo or touch any connections whilst the device is in operation Before starting any work on the device switch off all power feeds including those to any connected peripherals sensors and programmable devices etc with independent power supplies If the device is used correctly it...

Страница 31: ...ont face To avoid faults due to inadvertent activation switch the device off before cleaning the front panel Clean the surfaces using only a dry lint free cloth 7 3 Chemical resistance 7 3 1 Resistance of the touch screen The active area of the touch screen is resistant to the following chemicals when exposed to them for a period of up to an hour at a temperature of max 21 C Domestic and industria...

Страница 32: ...ure steam above 100 C long term effects of direct sunlight Keep these substances away from the front diaphragm Protect the display against direct sunlight The front diaphragm Autoflex EB is based on a polyester film with biaxial alignment It is highly resistant to solvents In accordance with the standard DIN 42 115 part 2 the front diaphragm is resistant to the following chemicals without any evid...

Страница 33: ... Isopropanol Methanol Ferric chloride 30 Formic acid methane acid 50 Hydrochloric acid 10 Hydrogen peroxide 25 Isophorone Methyl ethyl ketone butanone Nitric acid 10 Tetrahydrofuran Formaldehyde 37 in water Linseed oil Paraffin oil Petrol Silicone oil Turpentine substitute Universal brake fluid e g Castrol Girling Dibasic ester 6 Skydrol 500B4 Lixtop Potassium ferrocyanide Tetrachloro ethylene per...

Страница 34: ... 82 00 00 003 222002100_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 34 Application of 24 hours at 50 C Top Job Jet Dry Gumption Fantastic Formula 409 Grape juice Milk Ariel Persil Wisk Lenor Downey Ajax Vim Domestos Vortex Windex Application of less than 1 hour Glacial acetic acid pure acetic acid ...

Страница 35: ...nnect the device and its peripherals from the power supply 2 Unplug all plug connectors and cables NOTE Damage to the device If uninstallation is performed carelessly the device can fall out of the installation cut out or be damaged Do not tilt the device Secure the device against falling especially when taking it out of the installation cut out Fig 19 Undoing the screws 3 Undo equally the screws ...

Страница 36: ...berghof com 21 0099 82 00 00 003 222002100_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 36 Fig 20 Removing the securing clips 4 Remove the 8 securing clips Fig 21 Pushing the device out of the installation cut out 5 Push the device evenly forwards out of the installation cut out ...

Страница 37: ...the end of the device s life cycle you can return it to the manufacturer for a set fee The manufacturer will then deal with the recycling of the device Disposal in accordance with regional regulations Dismantle the device and disassemble it completely into its component parts Send the metal parts for metal recycling Sort the electronic parts circuit boards drives etc Dispose of the electronic scra...

Страница 38: ...ating temperature 0 C to 55 C front and rear of the device in compliance with installation requirements Relative humidity max 85 non condensing Transport and storage Operating temperature 20 C to 70 C Relative humidity max 85 non condensing Operation Installation integral securing clips Certification to product standards EN 61010 2 201 EN 61131 2 Touch operation Touch resistive Shock resistance Vi...

Страница 39: ...500 V DC test voltage Protection rating IP20 front IP65 Power supply 24 V power Supply voltage 24 V DC 15 20 SELV max ripple component 5 Power consumption Max 0 8 A peak current 1 2 A at 24 V DC Protection against reverse polarity yes Ethernet interface No type of interface 1x 10 100 Base T Connection system RJ45 Protocols TCP IP USB interface No type of interface 1x host USB 2 0 USB plug port A N...

Страница 40: ...identification plate Item Designation Item Designation 1 Device type description 6 Customer no 2 Identification no article no serial no and version as delivered condition 7 Supply voltage and maximum current 3 Production date 8 QR code Identification no 4 Manufacturer s address 9 CE mark 5 Mac addresses 10 Manufacturer s mark trademark The Version field delivered version specifies the ex works con...

Страница 41: ... Identification The characteristics of the device can be decoded from the identification key Fig 23 ET2115 identification key Unit type Unit family Screen size Screen format Resolution Initials for customer Processor core Clock frequency Touch points Touch 15 inch 15 6 Berghof Automation single dual dual light quad core 0 8 GHz 1 0 GHz single double multi resistive capacitive empty ...

Страница 42: ...www berghof com 21 0099 82 00 00 003 222002100_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 42 11 Standards and certificates 11 1 Standards Applicable directives EMC directive 2014 30 EC Applicable standards PLC standard EN 61131 2 2008 4 Safety provisions DIN EN 61010 2 201 ...

Страница 43: ... 0 ET2115 Berghof Automation GmbH Harretstrasse 1 72800 Eningen www berghof com 21 0099 82 00 00 003 222002100_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 43 11 2 UL certificate Fig 24 UL certificate page 1 of 2 ...

Страница 44: ...0_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 44 The devices are authorised to use the following mark Fig 25 cULus authorisation The devices have been awarded cULus authorisation according to standard UL 61010 2 201 NRAQ 7 Link http database ul com cgi bin XYV cgifind new LISEXT 1FRAME index html UL File Number E242595 ...

Страница 45: ... HANDBOOK 1 0 ET2115 Berghof Automation GmbH Harretstrasse 1 72800 Eningen www berghof com 21 0099 82 00 00 003 222002100_Anwenderhandbuch_Ethernet Terminal ET2115_EN docx 45 11 3 Declaration of conformity ...

Страница 46: ...are licence The firmware of the devices contains der free software Parts of this software are available under the following OpenSource licences amongst others GNU General Public License GPL GNU Lesser General Public License LGPL Mozilla Public License MPL FreeType License FTL The source code of the free software may be requested from Berghof Customer Service within three years pf delivery of the d...

Страница 47: ...GmbH Harretstr 1 72800 Eningen Germany T 49 7121 894 183 F 49 7121 894 100 e mail support controls berghof com www berghof com 12 2 Addresses CAN in Automation international manufacturer and user organisation for CAN users in automation CAN in Automation e V CiA Am Weichselgarten 26 91058 Erlangen headquarters can cia de www can cia de EtherCAT Technology Group ETG Headquarters Ostendstraße 196 90...

Страница 48: ...0 19 Fig 8 Block circuit diagram 20 Fig 9 Ethernet interface X4 21 Fig 10 USB interface X3 22 Fig 11 Start page with network settings 24 Fig 12 Information page 24 Fig 13 Network settings of the device 25 Fig 14 Setting the server IP 25 Fig 15 Changing the Lifeguard setting 26 Fig 16 Summary of the network settings 26 Fig 17 Location of the operating status LEDs 27 Fig 18 Function key S1 28 Fig 19...