![BERGHOF B-Primis ET-Prime 10 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/berghof/b-primis-et-prime-10/b-primis-et-prime-10_user-manual_2737025025.webp)
USER MANUAL 1.1 | B-PRIMIS ET-PRIME SERIES
Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen |
B-PRIMIS_ET-PRIME_EN_1.1.docx
25
5.1.1. Connecting the power supply
CAUTION
Live parts!
Before starting any work on the device, switch off all power feeds, including peripherals.
B-Primis ET Prime 7/10/15
Connect the power supply to plug X1 according to the following table.
Fig. 11: Power supply ET-Prime plug X1
Power supply plug X1
Pin
Designation
Assignment
9
L0+ 24 V
Power supply 24 V DC (
–15 %/+20 %)
B-Primis ET-Prime 7: max. 0,35 A (peak current 1.2 A)
B-Primis ET-Prime 10: max. 0.6 A (peak current 1.2 A)
B-Primis ET-Prime 15: max. 0.7 A (peak current 1.2 A)
10
unused
11
GND
M0 / GND
12
L0+ 24 V
Power supply 24 V DC (
–15 %/+20 %)
B-Primis ET-Prime 7: max. 0,35 A (peak current 1.2 A)
B-Primis ET-Prime 10: max. 0.6 A (peak current 1.2 A)
B-Primis ET-Prime 15: max. 0.7 A (peak current 1.2 A)
The following counterparts have been tested for the S2C-SMT 3.5 (Weidmüller) plug-in con-
nector and are approved for use with the device:
→
B2CF 3.50/12/180
Содержание B-Primis ET-Prime 10