B.
Parameters Re-Defined for PI Control
This section describes amendments to existing parameters when the PI Controller is uti-
lized.
This parameter defines the source for speed reference and Run/Stop control input. The val-
ues shown below replace those given on page 36.
◊
Value range: 0–11
Default: 3
This parameter defines the speed setpoint selector. The values shown below are in addition
to those given on page 38.
NOTE:
DIRECT = Maximum output (
32-FMAX
) at maximum input.
INVERSE = Minimum output (
31-FMIN
) at maximum input.
◊
Value range: 0–19
Default: 0
PARAMETER
RANGE
OR UNITS
LEVEL
DESCRIPTION
1A-FSTAT
Stator Frequency
–
2
Shows the stator frequency; the value may only be
read; it cannot be altered.
A1-FCORR
Frequency
Correction
0.00–400.0 Hz
2
Used to limit the variation of the PI Regulator around
the value of parameter
12-FOUT
.
A6-ERROR2 Final Error
–
2
This parameter is the Final Error of the PI Regulator.
It is calculated from PI output minus the value of
12-
FOUT
. The value may only be read.
A7-ERROR1 Initial Error
–
2
This parameter is the Initial Error of the PI Regulator.
It is calculated from
12-FOUT
minus feedback. The
value may only be read.
A8-SIPART
Integral Sum
–
2
This parameter is the sum of the integral term of the
PI Regulator. The value may only be read.
B3-KP
Proportional Gain
0–255
2
This parameter sets the proportional gain.
B4-KI
Integral Gain
0–255
2
This parameter sets the integral gain.
B5-KIN
VIN1 Scaling
0–255
2
This parameter sets the scaling for feedback termi-
nal VIN1.
21-MODE
– Input Mode
1P
DATA
CODE
SPEED CONTROL SOURCE
RUN/STOP CONTROL
0
Keypad
Keypad (Forward only)
1
VIN2 Terminals
Keypad (Forward only)
2
Keypad
Terminals (2-wire maintained contact)
3
VIN2 Terminals
Terminals (2-wire maintained contact)
24-FSEL
– Speed Setpoint Selector
2P
DATA
CODE
DESCRIPTION
16
Both VIN1 and VIN2 are direct.
17
VIN1 is inverted and VIN2 is direct.
18
VIN1 is direct with a 20% offset and VIN2 is direct.
19
VIN1 is inverted with a 20% offset and VIN2 is direct.
HINT!