Technical

 

data

 

 
 
 
 
 

(1)

Under nominal flow, 20°C,inlet droplet size 10µm - 50µm

 

 
 
 

MATERIALS 

Housing material 

Aluminium 

Fittings, Screws 

Brass, Brass-zinc plated, Steel 

Cover 

ABS 

Sealing 

NBR 

Cyclone element 

PA6 30% glass fibre, Aluminium, 

Corrosion protection 

Stainless Steel 1.4301 

Outside protection 

Anodized (optional) 

Lubricant 

Powder paint coated 

 

 

HOUSING 

PIPE SIZE 

[inch] 

FLOW CAPACITY 

DIMENSIONS [mm] 

VOLUME 

[l]

 

WEIGHT 

[kg] 

[Nm

3

/h] 

[scfm] 

F 01 WW 

3/8 

72 

42 

187 

88 

20 

80 

0,47 

0,7 

F 02 WW 

1/2 

96 

56 

256 

88 

20 

80 

0,6 

0,8 

F 03 WW 

1/2 

150 

88 

278 

106 

25 

100 

1,2 

1,3 

F 04 WW 

3/4 

216 

127 

278 

106 

25 

100 

1,2 

1,3 

F 05 WW 

282 

166 

252 

125 

32 

120 

1,57 

2,1 

F 09 WW 

1 ½ 

510 

300 

450 

125 

32 

160 

3,0 

3,2 

F 15 WW 

888 

522 

605 

160 

43 

180 

6,0 

5,1 

F 24 WW 

2 ½ 

1440 

847 

685 

160 

43 

200 

6,5 

6,3 

   F 46 WW * 

2760 

1624 

800 

240 

60 

300 

19 

12,9 

Flow capacity at 7 bar(g), 20°C 

*Stainless steel cyclone element 

 

CORRECTION FACTORS

 

To calculate the correct capacity of a given cyclone based on actual operating conditions, multiply the nominal flow capacity 
by the appropriate correction factor(s).  
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x C

OP 

 

[bar] 

10 

11 

12 

13 

14 

15 

16 

17  18  19  20 

[psi] 

29 

44 

58 

72 

87  100  115  130  145  160  174  189  203  218  232  247  261  276  290 

C

OP 

0,38  0,5  0,63  0,75  0,88  1  1,13  1,25  1,38  1,50  1,63  1,75  1,88  2,00  2,13  2,25  2,38  2,50  2,63 

 

 

 

Vessel characteristics 

Operating temperature 

1,5 - 65 °C 

35 - 149 °F 

Operating pressure 

0 - 20 bar(g) 

0 - 290 psi 

Efficiency(1) 

>98% 

Working medium: 

Fluid group 2 

B

C

A

D

G 1/2"

Содержание PUREBERG FWW

Страница 1: ...tor PUREBERG FWW Please read the following instructions carefully before installing cyclone housing unit into service Trouble free and safe operating of the unit can only be guaranteed if recommendati...

Страница 2: ...o the housing wall slowed down and accumulated at the bottom of separator housing as condensate The turbulent free zone in the lower part of the filter housing prevents condensate from being picked up...

Страница 3: ...1 510 300 450 125 32 160 3 0 3 2 F 15 WW 2 888 522 605 160 43 180 6 0 5 1 F 24 WW 2 1440 847 685 160 43 200 6 5 6 3 F 46 WW 3 2760 1624 800 240 60 300 19 12 9 Flow capacity at 7 bar g 20 C Stainless s...

Страница 4: ...part It is necessary to ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded Separator has been designed...

Страница 5: ...ly be used for GROUPE 2 fluids PED 2014 68 EU cyclone can not be used for explosive toxic flammable corrosive and GROUPE 1 fluids PED 2014 68 EU Warning internal corrosion can seriously reduce the saf...

Страница 6: ...safety and reliably operation Cyclone must be protected against injuries and non authorized substitution Operating pressure must correspond to design pressure Cyclone must be connected to pipeline wi...

Страница 7: ...commended for safe operation Carry out a check for leaks once the maintenance work has been finished Warranty exclusion The guarantee shall be void if The operating instructions were not followed with...

Отзывы: