16
EN
PAR.
DESCRIPTION
04
HYSTERESIS ON:
The value selected with this
parameter indicates when the heat request is
activated. The factory setting is 0,2°C, values
range between 0,0°C and 2,0°C. Heat requests
switch ON when the room temperature drop
below the room target temperature minus the
hysteresis ON value.
TECHNICAL SPECIFICATIONS
Relay switching capacity:
• Min 1mA,
• Max 2A a 30 Vc.c.
• Max 0,25 A a 230 VAC
Power rating: 2 x 1,5AAA - Alkaline batteries
Temperature setting: 3°C to 35°C in 0.2°C increments.
Display temperature: -9,9°C to 50°C in 0.2°C increments.
Install the thermostat in an environment with normal pol-
lution level.
The manufacturer reserves the right to change speci
fi
ca-
tion without prior notice - Consumers statutory rights are
not affected.
PAR.
DESCRIPTION
02
FROST PROTECTION TEMPERATURE:
The
weekly room thermostat has an internal an-
ti-frost function that switches on the boiler (only
when the boiler is properly set to allow the room
thermostat to activate/deactivate the boiler, i.e.
boiler in winter mode) if the room temperature
drops below the selected temperature. This
function is active all the time whatever the pro-
gramming time or the set temperature. By en-
tering the 02 parameter it is possible to adjust
the frost protection temperature: the factory
setting is 5°C, the 02 parameter can be adjus-
ted between 3°C and 10°C. the frost protection
selected temperature becomes the minimum
settable value for the economy temperature (in-
side the main menu).
WARNING!
This anti-frost
protection is not intended to be the main con-
trol to protect the entire heating system and the
boiler during a freezing period.
03
HYSTERESIS OFF:
The value selected with
this parameter indicates when the heat request
is stopped. The factory setting is 0,4°C, val-
ues range between 0,0°C and 2,0°C. Heat re-
quests switch OFF when the room temperature
reaches the room target temperature plus the
hysteresis OFF value.
EN
Содержание HRT-177WS
Страница 63: ...63 GR 2A 30VDC 0 25A 230VA AC ADVANCE...
Страница 64: ...64 GR LCD AUTO ON OFF OFF OFF PARTY ON ON OFF ADVANCE ON OFF AUTO 24 60 OFF 15 59 ON 16 00 18 59 ON...
Страница 65: ...65 GR AUTO ON OFF ON ON OFF 16 C OFF 5 C PARTY ADVANCE OFF 1 2 ADVANCE OFF 3 3 PL UTO PARTY OFF ECOt...
Страница 66: ...66 GR OFF AUTO H C t CL 1 7 ON OFF _ PL 01 02 03 OFF 04 ON 05 RF 06 EHIt Exit 1 5 mm 2 2 1 1 5 AAA 2...
Страница 69: ...69 GR PL 53 PL 4 PAR 01 02 21 C 16 C 5 C OFF 0 4 C OFF 0 4 C ON 0 2 C ON 0 2 C 1 OFF...
Страница 70: ...70 GR PAR 02 03 5 C 03 3 C 10 C 03 OFF 0 4 C 0 0 C 2 0 C OFF OFF PAR 04 ON 0 2 C 0 0 C 2 0 C O O...
Страница 71: ...71 GR 1mA 2A 30 VDC 0 25 A 230 VAC 2 x 1 5 AAA 3 C 35 C 0 2 C 9 9 C 50 C 0 2 C...
Страница 80: ...HRT 177WS Rev 1 10 13...