12
EN
provides you both the room thermostat function and the
weekly clock function.
When in AUTO mode, the central heating will be ON/OFF
according to the programmed times and according to the
set comfort temperature (the ON command is identi
fi
ed by
the
fl
ame icon). When the heating will be commanded ON
the set-point in the room will be the comfort one. In case of
off programmed times, the set temperature is the “economy
temperature”, selectable inside the main menu (16°C is the
default value).
When in OFF mode the heating requested will be switched
on when the room temperature drops under the frost pro-
tection value (default is 5°C); this value can be modi
fi
ed
inside the technical menu.
When in PARTY mode the heating request is permanently
on according the selected comfort temperature that can
be modi
fi
ed any time rotating the encoder and pressing to
con
fi
rm.
When in COOLING mode (summer mode) the room ther-
mostat activates or deactivates the cooling system. This
function must be used only if a cooling system is available
and only with an electric connection speci
fi
cally made.
ENCODER
The encoder has three functions: selection of the set tem-
perature, set the ADVANCE function and setting the ther-
mostat. If the status mode of the thermostat is OFF, only the
pressing functionality is active; any rotation done does not
generate any modi
fi
cation.
1. Rotate to select the desired temperature and press to
enter.
2. Press once to activate or deactivate the ADVANCE
function. Use to “advance” the heating to an ON or OFF
period.
3. Press for 3 seconds to enter menu. Rotate to scroll
through the menu choosing between status mode, eco-
nomy temperature setting, time of day, day of the week,
programmed times day by day, technical menu (PL) and
exit. Press again to modify selected item.
Status mode: rotate to change the thermostat mode
between AUTO, PARTY, and OFF, press to save. The press
from status mode automatically escapes from menu.
Economy temperature ECOt: Rotate to select the desired
economy temperature and press to enter. This temperat-
ure is used when programming time is OFF in AUTO status
mode.
Heating and cooling mode selection H- -C: Rotate to select
the thermostat mode between Ht (heating) and CL (cool-
ing), press to save. The selected mode is identi
fi
ed on the
display with the presence of the radiator display (radiator
icon on means heating mode, radiator icon OFF means
cooling mode).
Time of the day: rotate to change the hours, press to save.
Move to minutes; rotate to change minutes, press to save.
Day of the week: rotate to change the day, press to save
Programmed times day 1-7: rotate clockwise to set hour
ON, rotate anticlockwise to select hour OFF. Clockwise and
anticlockwise rotation move ahead the time. Press to save.
Rotate clockwise to move to the following day. It is possible
to program together days 1…5 and days 6-7 with the same
pattern in a single operation.
PL: rotate to select the password value, press to enter in-
side the technical menu. Rotate to select the parameters:
01 = calibration of the temperature sensor, 02 = frost pro-
tection temperature selection, 03 = hysteresis OFF value
Содержание HRT-177WS
Страница 63: ...63 GR 2A 30VDC 0 25A 230VA AC ADVANCE...
Страница 64: ...64 GR LCD AUTO ON OFF OFF OFF PARTY ON ON OFF ADVANCE ON OFF AUTO 24 60 OFF 15 59 ON 16 00 18 59 ON...
Страница 65: ...65 GR AUTO ON OFF ON ON OFF 16 C OFF 5 C PARTY ADVANCE OFF 1 2 ADVANCE OFF 3 3 PL UTO PARTY OFF ECOt...
Страница 66: ...66 GR OFF AUTO H C t CL 1 7 ON OFF _ PL 01 02 03 OFF 04 ON 05 RF 06 EHIt Exit 1 5 mm 2 2 1 1 5 AAA 2...
Страница 69: ...69 GR PL 53 PL 4 PAR 01 02 21 C 16 C 5 C OFF 0 4 C OFF 0 4 C ON 0 2 C ON 0 2 C 1 OFF...
Страница 70: ...70 GR PAR 02 03 5 C 03 3 C 10 C 03 OFF 0 4 C 0 0 C 2 0 C OFF OFF PAR 04 ON 0 2 C 0 0 C 2 0 C O O...
Страница 71: ...71 GR 1mA 2A 30 VDC 0 25 A 230 VAC 2 x 1 5 AAA 3 C 35 C 0 2 C 9 9 C 50 C 0 2 C...
Страница 80: ...HRT 177WS Rev 1 10 13...