background image

1 | GENERAL INFORMATION

5

1.3

Unit description

BREVA EX 

is a heat pump outdoor unit that can be coupled to 

indoor units of the same series for the air-conditioning of small/
middle-sized rooms. Designed for outdoor installation, it is suitable for
use in residential and small business premises.
The rotary-type compressor is controlled via DC-Inverter control with
continuous modulation from 20% to 110%, thus ensuring high energy
standards. The fan DC motor improves performance and sound comfort.
The expansion valve electronically optimises the flow of refrigerant within
the circuit (excluding BREVA EX 9000-1).
The  R32  refrigerant  allows  high  yields,  thus  placing 

BREVA  EX 

the most efficient devices on the market.

1.4

Safety and adjustment devices

The device safety and setting are achieved thanks to

- compressor motor thermal protection, which is triggered incase

the current consumed by the compressor is excessive

- gas delivery temperature sensor, which transmits the detected

value to the electronic board that is triggered in case of
over-temperature (116°C)

- anti-freeze sensor, which transmits the temperature value as

detected by the heat exchanger to the electronic board that is
triggered when the heat exchanger is clogged by frost formations

- suction temperature sensor, which transmits the detected value

to the electronic board that is triggered in order to adjust the flow
of refrigerant gas or to stop the unit in case of overtemperature
(40°C)

- outdoor air temperature sensor, which transmits the detected

value to the electronic board that is triggered in order to adjust
the operation of the unit indoor components to the variation of
weather conditions

Safety device replacement must be carried out by 

Technical 

Support Service, using only original components. Please refer to the
spare parts catalogue.

IT IS FORBIDDEN to operate the device with faulty safety systems.

1.5

Identification

The unit can be identified through the technical data plate:

Technical data plate

Contains the device's technical and performance data.

The tampering, removal, or absence of the identification plates will
not allow the product to be properly identified by its serial number.

1.6

Layout

1

Upper panel

7

Electric fan

13

Filter

2

Fan protection grille

8

Intake separator

14

Electronic expansion valve

3

Support bracket

9

Rotary compressor

15

Terminal board for electric connections

4

Connections cover

10

Muffler

16

Electric panel cover

5

Handle for handling

11

Gas line connection

6

Heat exchanger

12

Liquid line connection

Содержание 20171586

Страница 1: ...Installer manual BREVA EX EN...

Страница 2: ...he device s correct and easy installation Thank you again and keep up the good work BERETTA S p A COMPLIANCE BREVA EX heat pumps are compliant with the following European Directives Low Voltage Direct...

Страница 3: ...to service 3 3 Ordinary maintenance 3 4 Segnalazione di funzionamento e allarmi 4 DISPOSAL The following symbols are used on the product The R32 refrigerant gas is slightly inflammable and odourless A...

Страница 4: ...rigerant gas operate carefully so as to avoid damaging the gas circuit and the fin bank Do not place any inflammable object spray cans within a 1 metre radius from the air expulsion According to EU Re...

Страница 5: ...ectronic board that is triggered when the heat exchanger is clogged by frost formations suction temperature sensor which transmits the detected value to the electronic board that is triggered in order...

Страница 6: ...Wh annum 269 Heating performance 3 Capacity at rated air flow kW 5 20 Capacity at minimum air flow kW 1 60 Capacity at maximum air flow kW 6 10 Absorbed power at rated air flow kW 1 40 Absorbed power...

Страница 7: ...x current input A 12 50 Minimum current consumption A 2 50 Electrical characteristics Power supply V Ph Hz 220 240 1 50 Compressor Compressor Tipo Rotativo Doppio Oil Tipo RM LP56EG Oil charge l 0 48...

Страница 8: ...7 3 5 A 6 5 A Heating Combinations Single nominal capacity Total nominal capacity Total power input Total current input COP Energy class SCOP Energy class Indoor units Indoor units A B Unit A Unit B M...

Страница 9: ...nd delivers it to the room air thereby heating it During the summertime the cycle is reversed and the thermal energy is extracted from the room air which is cooled and is delivered to the outdoor air...

Страница 10: ...ocument envelope Instruction s book for the installer and for the Technical Service in Italian Instruction s book for the installer and for the Technical Service in English Warranty Spare parts labels...

Страница 11: ...cking material must not be disposed of in the surrounding environment and must be kept out of children reach as it can be dangerous It must be disposed of according to the regulations in force 2 6 Pla...

Страница 12: ...ent the air flow from being blocked or install a roofing to protect it Adequate anti freeze systems should be used for installations in extremely cold areas where there is a possibility of freezing Wh...

Страница 13: ...ing table Model 18000 2 Connection pipes h1 m 7 50 h2 m 7 50 h max m 15 H m 15 H m 15 L1 L2 m 20 L1 L2 m 30 Maximum length with standard charge m 20 Additional charge g m 20 The R32 refrigerant gas is...

Страница 14: ...8 60 Pipe A mm inches mm 6 35 1 4 17 9 52 3 8 22 12 7 1 2 26 15 88 5 8 29 bring line ends with flare connection close to their coupling on the unit manually rotate the flare nuts by 3 4 turns tighten...

Страница 15: ...lug 5 Hex wrench If required remove the valve covering plug operate on the valve shaft with an hex wrench open or close according to what is needed immediately stop as soon as the valve shaft has reac...

Страница 16: ...let the vacuum pump work for at least 15 minutes reach a pressure that is close to 0 1 Mpa close the low pressure valve of the pressure gauge unit switch off the vacuum pump wait 5 minutes check that...

Страница 17: ...se the same vacuum pump with different refrigerants The vacuum pump requires regular maintenance and the oil s clarity must also be checked After having created the vacuum and established the electric...

Страница 18: ...must be powered with a separate electric circuit 1 Electric connection input position the system s main switch in the OFF position Wait 10 minutes before touching the device electric components Check...

Страница 19: ...esponds to the nominal value 10 with a maximum phase imbalance of 3 all of the power network disconnect devices must be equipped with contact openings 3 mm in order to allow for complete disconnection...

Страница 20: ...nded operating conditions the unit is able to stop and start up again Should any of the above listed controls have problems turn the device off and call the Technical Service immediately Do not touch...

Страница 21: ...ck with a tester that the voltage between the power supply connectors of the main electronic board is lower than 10 Vdc Yearly operations The annual maintenance plan includes the following checks powe...

Страница 22: ...ion booklet for the installer Tabella allarmi Faults are signalled by means of LED 1 blinking Led 1 Description 1 External unit microprocessor fault 2 Power module fault IPM 3 Main electronic board pr...

Страница 23: ...shall be disposed of separately so as to recover and recycle them Refrigerant and oil must be recovered and not dispersed into the environment At the end of its service life the device shall be dispo...

Страница 24: ...1 277111 Fax 39 0341 277263 info berettaboilers com www berettaclima it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment...

Отзывы: