background image

2 | INSTALLATION

12

2.8

Positioning

BREVA EX 

devices must: 

- be positioned on a level surface that is capable of supporting their

weight

- be positioned on a sufficiently rigid surface that will not transmit

any vibrations to the underlying or adjacent rooms

Use the anti-vibration supports supplied with the device.

Model

18000-2

A

mm

130

B

mm

510

C

mm

160

D

mm

313

They can be placed on the floor or suspended on supporting brackets.

Positioning on floor

1

Fastening screw M4

2

Anti-vibration element (supplied)

3

Spirit level

- screw the unit to the ground
- tighten using a torque wrench

- apply a tightening torque of 3.5 Nm

Provide for lifting of the unit from the floor:

- 20 mm without conveying of the condensate outlet
- 90 - 100 mm to allow for the condensate discharge

If the device is installed in an area that is subject to heavy snowfalls,
place the unit in a raised position so as to prevent the air flow from
being blocked or install a roofing to protect it.

Adequate anti-freeze systems should be used for installations in
extremely cold areas, where there is a possibility of freezing.

While operating in heating mode, the unit generates condensate,
which will deposit on the support surface if there is not discharge.
This could freeze if the outdoor temperatures are below zero, thus
creating a hazard. In this case, appropriate barriers should be
installed in order to prevent people from approaching the unit.

1

Lifting from the top

2

Condensate discharge connector

Model

18000-2

Connections

Condensate
drain
connection

mm

2 x 16

Hanging position

Properly sized supporting brackets must be used if the device is
installed in suspension.

Ensure that the wall section does not include bearing elements,
pipes or electric lines.

1

Supporting brackets

2

Anti-vibration element (supplied)

3

Fastening screw M4

2.9

Installation on old systems or systems in
need of upgrading

When 

 

BREVA EX 

is installed on old systems or systems in need 

of upgrading, it is recommended to ensure that:

Содержание 20171586

Страница 1: ...Installer manual BREVA EX EN...

Страница 2: ...he device s correct and easy installation Thank you again and keep up the good work BERETTA S p A COMPLIANCE BREVA EX heat pumps are compliant with the following European Directives Low Voltage Direct...

Страница 3: ...to service 3 3 Ordinary maintenance 3 4 Segnalazione di funzionamento e allarmi 4 DISPOSAL The following symbols are used on the product The R32 refrigerant gas is slightly inflammable and odourless A...

Страница 4: ...rigerant gas operate carefully so as to avoid damaging the gas circuit and the fin bank Do not place any inflammable object spray cans within a 1 metre radius from the air expulsion According to EU Re...

Страница 5: ...ectronic board that is triggered when the heat exchanger is clogged by frost formations suction temperature sensor which transmits the detected value to the electronic board that is triggered in order...

Страница 6: ...Wh annum 269 Heating performance 3 Capacity at rated air flow kW 5 20 Capacity at minimum air flow kW 1 60 Capacity at maximum air flow kW 6 10 Absorbed power at rated air flow kW 1 40 Absorbed power...

Страница 7: ...x current input A 12 50 Minimum current consumption A 2 50 Electrical characteristics Power supply V Ph Hz 220 240 1 50 Compressor Compressor Tipo Rotativo Doppio Oil Tipo RM LP56EG Oil charge l 0 48...

Страница 8: ...7 3 5 A 6 5 A Heating Combinations Single nominal capacity Total nominal capacity Total power input Total current input COP Energy class SCOP Energy class Indoor units Indoor units A B Unit A Unit B M...

Страница 9: ...nd delivers it to the room air thereby heating it During the summertime the cycle is reversed and the thermal energy is extracted from the room air which is cooled and is delivered to the outdoor air...

Страница 10: ...ocument envelope Instruction s book for the installer and for the Technical Service in Italian Instruction s book for the installer and for the Technical Service in English Warranty Spare parts labels...

Страница 11: ...cking material must not be disposed of in the surrounding environment and must be kept out of children reach as it can be dangerous It must be disposed of according to the regulations in force 2 6 Pla...

Страница 12: ...ent the air flow from being blocked or install a roofing to protect it Adequate anti freeze systems should be used for installations in extremely cold areas where there is a possibility of freezing Wh...

Страница 13: ...ing table Model 18000 2 Connection pipes h1 m 7 50 h2 m 7 50 h max m 15 H m 15 H m 15 L1 L2 m 20 L1 L2 m 30 Maximum length with standard charge m 20 Additional charge g m 20 The R32 refrigerant gas is...

Страница 14: ...8 60 Pipe A mm inches mm 6 35 1 4 17 9 52 3 8 22 12 7 1 2 26 15 88 5 8 29 bring line ends with flare connection close to their coupling on the unit manually rotate the flare nuts by 3 4 turns tighten...

Страница 15: ...lug 5 Hex wrench If required remove the valve covering plug operate on the valve shaft with an hex wrench open or close according to what is needed immediately stop as soon as the valve shaft has reac...

Страница 16: ...let the vacuum pump work for at least 15 minutes reach a pressure that is close to 0 1 Mpa close the low pressure valve of the pressure gauge unit switch off the vacuum pump wait 5 minutes check that...

Страница 17: ...se the same vacuum pump with different refrigerants The vacuum pump requires regular maintenance and the oil s clarity must also be checked After having created the vacuum and established the electric...

Страница 18: ...must be powered with a separate electric circuit 1 Electric connection input position the system s main switch in the OFF position Wait 10 minutes before touching the device electric components Check...

Страница 19: ...esponds to the nominal value 10 with a maximum phase imbalance of 3 all of the power network disconnect devices must be equipped with contact openings 3 mm in order to allow for complete disconnection...

Страница 20: ...nded operating conditions the unit is able to stop and start up again Should any of the above listed controls have problems turn the device off and call the Technical Service immediately Do not touch...

Страница 21: ...ck with a tester that the voltage between the power supply connectors of the main electronic board is lower than 10 Vdc Yearly operations The annual maintenance plan includes the following checks powe...

Страница 22: ...ion booklet for the installer Tabella allarmi Faults are signalled by means of LED 1 blinking Led 1 Description 1 External unit microprocessor fault 2 Power module fault IPM 3 Main electronic board pr...

Страница 23: ...shall be disposed of separately so as to recover and recycle them Refrigerant and oil must be recovered and not dispersed into the environment At the end of its service life the device shall be dispo...

Страница 24: ...1 277111 Fax 39 0341 277263 info berettaboilers com www berettaclima it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment...

Отзывы: