In  the  case  the  outside  sensor  is  fitted 

(external  temperature  displayed)  the 

 

and 

 buttons  increase  or  decrease  of 

equivalent  degree  indicated  on  display, 
the room comfort level (from – 5 to +5) 
 

 HOLIDAY  mode  with  choice  how 

many day off (by increasing or decreasing 

using  the  button 

 and 

 ).  The 

heating request to the boiler is to maintain 
the  economy  temperature  on  the  room 
(T2).  The  number  of  days  off  is 
considered  on  the  day  starting  from 
midnight. After the counter down is ended 
the programmer switch to AUTO mode. 

 PARTY  mode  automatically  switch 

the 

programmer 

ON 

to 

comfort 

temperature (T1). This status is forced up 

to  midnight,  after,  the  programmer  goes 
back to the programmed timing fascia.  
Other  functions  (common  to  crt  and 
rEc modes): 
Battery low 
Alarms and reset (only for rEc type) 
Technical menu (only for experts) 
 

O

PERATING INSTRUCTIONS

 

 
The  programmer  is  factory  set  as  room 
thermostat  type  (crt).  Most  of  the 
parameters  are  already  set,  at  the  start 
up it is necessary to set the time and the 
day  (please  note  no  solar  fuse  is  pre-
charge  inside  therefore  if  during  the  year 
there  is  time  modification  it  must  be 
adjusted). 
The  following  operation  must  done  at 
start up 
E

ND USER MENU 

(

MAIN MENU

Содержание 20050684

Страница 1: ...1 PROGRAMMABLE 7 DAY THERMOSTAT Installation and user instruction This instructions to be retained by the user...

Страница 2: ...manual prior to installation or use Shock Hazard This unit must be installed by a competent person in accordance with local regulation or other relevant national regulations and codes of good practic...

Страница 3: ...N OFF command to the boiler Connect the cable to room thermostat connection on the boiler Maximum switching load of 2A at 30VDC or 0 25A at 230VAC rct To be used only when boiler is set in a zone valv...

Страница 4: ...4 Fast room temperature adjusting buttons Fast DHW adjusting buttons rEc only Heating mode button Programming button...

Страница 5: ...5 Display Temperature sensor Adjusting buttons Heating mode button Batteries flap...

Страница 6: ...llation instructions It is recommended that this device is installed by a qualified electrician PACKING LIST QTY 7 day programmer 1 Anchors and screws 4 Double side adhesive 3 Instructions 1 Carton in...

Страница 7: ...rence to drill the wall In the case of using anchors the transmitter box must be open to fix the screws to the anchors internally the box See the diagrams below for removal from and re assembly to bac...

Страница 8: ...CTIONS The Beretta Programmable 7 day Thermostat has the following functions Type Room thermostat crt for the display appearance in this mode please refer to the relevant section of this manual The in...

Страница 9: ...itching between the 4 status OFF AUTO PARTY HOLIDAY OFF mode the heating request to the boiler is off on display there is not equivalent icon the heating layer and the programming fascia is off With t...

Страница 10: ...e display appearance in this mode please refer to the relevant section of this manual The internal temperature sensor detects the temperature and comparing with the set point calculates the most suita...

Страница 11: ...rotection function is active The DHW function is active and it is possible to increase or decrease the target temperature by pressing the and buttons AUTO mode the heating request is according the pro...

Страница 12: ...tch to AUTO mode PARTY mode automatically switch the programmer ON to comfort temperature T1 This status is forced up to midnight after the programmer goes back to the programmed timing fascia Other f...

Страница 13: ...f the triangle buttons and press again the button to enter inside the single setting the scrolling give access to the following settings Attention the TYPE of the device that is part of the main menu...

Страница 14: ...set Setting the day Unset Setting the programming fascia Unset Setting the domestic hot water temperature only rEc type 42 C tyPE Setting the TYPE crt PL Setting the technical menu password required S...

Страница 15: ...tton to enter and exit Set the day of the week Use the and to increase or decrease Use the button to enter and exit Set the programming heating fascia Use the to select the day only ahead not back Use...

Страница 16: ...only for boilers installed with tank and sensor Parameter active only if the parameter 24 inside the technical menu is set ON Set the programming fascia in the same way used for heating fascia The se...

Страница 17: ...reset the set of factory parameters are recharged in the controller memory A83 only for rEc mode the cable between the programmer and the boiler is broken or not connected properly There is no communi...

Страница 18: ...boiler is set for low temperature i e floor heating Curves from 1 to 3 are used when the boiler is used for high temperature i e radiator heating Selection of the climatic curve can be made inside the...

Страница 19: ...The boiler will switch ON The central heating symbol and bar is a proportional indication of the set point of the desired temperature in the room Each bar represents to 2 C They will disappear when t...

Страница 20: ...ndicate whether the current set point for the current time is night or day The party icon is lit up when the party mode is selected In this mode the central heating fascia bar will be completely lit u...

Страница 21: ...rtional indication of the set point of the desired temperature in the room Each bar represents to 2 C They will disappear when the central heating is turned OFF In case of external sensor fitted the b...

Страница 22: ...If the whole bar is black the set point is the comfort T1 They will disappear when the central heating is turned OFF The day icon and the night icon indicate whether the current set point for the cur...

Страница 23: ...ler to the installation Following instructions are dedicated to expert personnel as they have a deep impact on the working mode of your boiler and your system To enter inside the PL menu it is request...

Страница 24: ...iler 09 Min set point heating 30 C 30 C 85 C Type rEc Use the button to decrease and the button to increase the temperature value The value is automatically memorized when moving to the next parameter...

Страница 25: ...parameter 13 Calibration of the room sensor Actual Type rEc and crt Use the button to decrease and the button to increase the reference room temperature Use this parameter in case of not proper insta...

Страница 26: ...ton to decrease and the button to increase the hysteresis OFF of the device The value is automatically memorized when moving to the next parameter 19 Hysteresis ON 0 5 C 0 0 2 0 Type rEc and crt Use t...

Страница 27: ...k on DHW OFF Type rEc Use the and the button to switch ON or OFF the programming time on the DHW production via a tank with sensor function active only with boiler connected to a tank with sensor cont...

Страница 28: ...ing capacity crt only Min 1mA Max 2A at 30 VDC Max 0 25A at 230 VAC Power rating 2 x 1 5AA Alkaline batteries only for crt type OT contact for bus protocol only Never supply with 230V this contact Rem...

Отзывы: