13
Installation
6006244_0 – 30.05.2022
EN
3.4.4
Hang the device in place
D
WARNING!
Danger of injuries through improper handling!
Hanging the device requires a great deal of physical exertion
due to its size and weight. If the device falls down, serious
injuries are possible.
☞
Three persons are required to hang the device.
☞
Ensure stable footing when hanging the device.
☞
Ensure that no other people are in the working area.
D
ATTENTION!
Danger of property damage through improper handling!
Hanging the device requires a great deal of physical exertion
due to its size and weight. If the device falls, the device,
kitchen furnishings and other objects could be damaged.
☞
Cover the cooled hob.
☞
Keep the installation area clear.
< 800
☞
Have two persons lift the hood body.
☞
Align the hood body.
y
The distance to the ceiling mounting plate must be
less than 800 mm.
y
The mains cable is at the rear on the right when
viewed from the front.
D
ATTENTION!
Danger of property damage due to improper hanging on
the cables!
The cable cannot be wound up correctly due to obstructions
or irregularities on the cable guide.
☞
Ensure that the device is hanging freely and straight on
the cables.
Two persons hold the hood body and a third person carries
out the following tasks:
☞
Guide the support cable’s mounting sleeves into the
appropriate threaded bolts on the ceiling mounting plate.
☞
Screw in the mounting sleeves until they stop on the
threaded bolts on the ceiling mounting plate.
☞
Ensure that all four support cables are tensioned.
The hood body can now hand freely on the support cables.
Содержание Skyline Frame BIH 100 SKF
Страница 28: ...6006244_0 30 05 2022 ...