20
Installation
6004067_a – 01.08.2018
The connection is made through cable terminals on a
detachable plug on the fan box.
D
ATTENTION!
Risk of damage through incorrect connection!
A mix-up of the control wires can result in damage to the
electronics.
☞
Be careful not to mix up connections when connecting
the control wires: Core 1 on terminal 1, core 2 on
terminal 2.
2.
1.
Wall box
☞
Connect the wall box as follows:
y
Core 1 on terminal 1
y
Core 2 on terminal 2
y
The wall box is closed when the control contacts are
open.
y
The wall box is open when the control contacts are
closed.
Window contact switch
☞
Connect the window contact switch as follows:
y
Blue/white core to terminal 3
y
Brown/green core to terminal 4
y
The hood‘s fan is only operational when the window is
open.
Under-pressure monitor
y
The hood‘s fan is only operational when no critical under-
pressure is determined in the room.
3.5.9
Connect exhaust air ducting (with exhausted
air or hybrid operation)
Extracted air mode
1.
2.
☞
Fit the exhaust outlet onto the guide on the fan housing.
☞
Seal the transition between the exhaust outlet and the
guide with the help of sealing tape.
☞
Ensure that the exhaust air duct is correctly fitted.
Hybrid mode
1.
2.
☞
Fit the exhaust outlet onto the collar of the hybrid filter.
☞
Ensure that the exhaust air duct is correctly fitted.