21
Installation
6006047_0 – 02.09.2021
EN
3.5.9
Establish electrical power supply
D
WARNING!
Risk of death due to electric shock!
Touching live parts can cause an electric shock, burns or
death.
☞
Make sure that the following work is only carried out by
qualified electricians.
☞
Ensure that the voltage supply is and remains
disconnected while the following work is in progress.
☞
Observe the voltage specifications on the ratings plate.
☞
Connect the hob to the on-site power supply. The junction
box is located on the underside of the device.
3-phase connection of the hob:
L1 black
Phase for left cooking zones
L2 grey
Phase for right cooking zones
L3 brown
Phase for fan
N
blue
Neutral conductor
PE green/yellow Earth
Cable
H 05 VV - F, H 05 RR - F,
Diameter 5 x 2.5 mm
2
Fuse
16 A
For a 2-phase connection (fuse 20 A), L2 and L3 must be
bridged.
For a 1-phase connection (fuse 40 A), L1, L2 and L3 must be
bridged.
☞
Route the cables so that they are not kinked, crushed or
damaged and do not come into contact with hot parts of
the device.
☞
Ensure that the cable is not disturbed during replacement
of the filter filling.
☞
Make sure that the device can be disconnected on all
poles from the electricity supply after installation.
Recirculating air kit DL BUR
☞
Insert the cold appliance plug into the connection socket
on the recirculated air filter.
☞
Plug the mains plug into the socket.
After switching on the power supply, the device is ready for
operation.
3.5.10 Check and carry out commissioning
D
ATTENTION!
Risk of disruptions due to moisture in the device!
If the device is moved from a cold environment into a hot
one, condensation may form inside.
☞
Wait about 2-3 hours before bringing the device into
service.
☞
Ensure that the device is accessible for maintenance work
at all times (e. g. with a removable rear panel or service
cover). The space must be sufficiently large to allow for
removal of the recirculated air filter.
☞
Check that an all-pole isolating device (min. 3 mm contact
gap) is present.
☞
Check that the mains cable and the electrical connection
cable are not kinked, crushed or damaged.
☞
Ensure that the device is not operated without
recirculated air filter or without exhaust elements.
☞
Ensure that the adapters of the air-carrying components
(e.g. conduit bend, shallow duct sections) are sealed with
sealing strip.
☞
Ensure that air outlets are not closed or covered.
☞
With recirculated air devices: Make sure that the
ventilation slots are free.
☞
Make sure that the protective film is removed.
☞
Check the correct functioning of the device.
D