9
EN / CZone® Contact 6 PLUS User & Installation Manual
CONNECTIONS
The Contact 6 PLUS has a convenient output connector that requires no crimping tools and accepts cables from 24AWG
to 8AWG (0.5 - 6mm). The unit has no power key and will turn on when power is applied to the network. The module
will continue to draw power even when it is not in operation. It is recommended that a battery isolator switch is installed
for when the system is not in use.
1. Feed output wires through cable grommet
2. Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten
screws to 4.43 in/lbs (0.5NM).
3. Insert plug firmly into module and tighten 2x retaining screws.
4. Connect CZone Smart Harness to network port. If not using the CZone Smart Harness, connect a NMEA2000
drop cable from the NMEA2000 backbone (do not power up network yet).
5. Connect the appropriate size power supply cable to the M6 positive stud and tighten to 35 in/lbs (4NM), ensuring
washers are installed as per diagram.
IMPORTANT
- The positive cable must be sufficient size to carry the maximum current of all loads connected
to the Contact 6 PLUS. It is recommended to have a fuse/circuit breaker rated to protect the cable.
1
4
3
2
5