background image

Copyright © 2007 BEP Marine Limited. All rights reserved. A product of New Zealand.  

Page   of 2

VOLTAGE SENSITIVE RELAY

DUAL BATTERY CHARGING MADE EASY

  Dual battery charging made easy

  Protects electronics on house battery circuit from engine start up spikes

  Fully automatic

www.bepmarine.com

VOLTAGE DROP CHART

Total Cable 

Length (m)

Total Cable 

Length (ft)

Amps

Voltage 

Drop (%)

mm²

AWG

3

3

50

00

2.3%

3%

4 mm

6 mm

0

2

2

6

6

50

00

3%

3.5%

6 mm

0 mm

0

7

3

3

9

9

50

00

2.7%

3.4%

0 mm

6 mm

7

5

4

4

2

2

50

00

3.6%

2.6%

0 mm

25 mm

7

3

5

5

5

5

50

00

2.8%

3.3%

6 mm

25 mm

5

3

6

6

8

8

50

00

3.4%

3.9%

6 mm

25 mm

5

3

7

7

2

2

50

00

3.9%

4.6%

6 mm

25 mm

5

3

8

8

24

24

50

00

2.6%

25 mm

3

SPECIFICATIONS

Continuous 25 Amps
Intermittent 40 Amps
Ignition Protected UL07

System size

2 V DC 

24 V DC

Engages

3.7 V DC 27.4 V DC

Disengages

2.8 V DC 25.6 V DC 

24 V DC system is 70-25A-24V

Z168

BEP’s unique VSR

Modern charging systems must be able to safely charge two or 
more different types of batteries from one engine. 
Now, thanks to BEP’s unique VSR (Voltage Sensitive Relay) boat 
owners can enjoy the benefits of fully charged engine starting 
batteries and deep cycle house batteries with one easy-to-install 
charging system.

70-25A (SINGLE SENSE) VSR OPERATION

The Voltage Sensitive Relay (VSR) allows two batteries to be 
charged at the same time. When the engine is started and the start 
battery reaches 3.7 volts, the VSR engages, allowing two battery 
banks (start and house) to be charged simultaneously. When the 
voltage drops below 2.8 volts (eg the engine is stopped), the VSR 
disengages, separating the batteries.
This system eliminates the possibility of draining the wrong battery 
and protects sensitive electronic equipment powered from the 
house battery from harmful engine start up spikes.

70-25A-DS (DUAL SENSE) VSR OPERATION

Same as the 70-25A with the added feature of dual sensing. 
This allows the unit to sense the voltage of both batteries that it is 
connected between. If either battery is receiving a charge the VSR 
will activate paralleling the two battery banks.
The 70-25A-DS is designed for situations where a battery charger 
or second charging source is used into the house battery.

Q: To which side of the battery switch should the VSR be wired?

 

A: It is vital to follow the wiring installation diagram which shows 
correct connection to the master switch. BEP only recommends 
the supplied option. Other options can lead to accelerated battery 
discharge as the sense circuit draws 0.0 Amps continuously. The 
output wire of the VSR should always be connected to the battery 
side of the House battery switch to ensure true isolation of house 
circuits if the VSR is engaged.

Q: Why does the LED stay on after engine is turned off? 

A: System voltage has not dropped below 2.8 V DC due to battery 
charging. VSR will disengage once residual battery voltage drops 
below 2.8 V DC.

Q: How do I ensure that the correct size of battery is matched 
to my VSR?

 

A: See the battery sizing  chart on next page.

Q: Why does my VSR ‘chatter’? 

A: Because the charging system is too small for the batteries and 
this is not allowing the VSR to work properly. Instead, once the 
starting battery has reached the right voltage and the house battery 
is connected the systems voltage is ‘caving down’ below 2.7 volts 
and the relay is automatically disconnecting. The voltage then rises, 
the relay re-engages; then the voltage drops the relay disengages 
and the ‘chattering’ sound is heard as the relay quickly switches in 
and out. Refer to battery sizing chart on next page.

More information can be found on our Website www.bepmarine.com.

Important information

Frequently asked questions

IMPORTANT

It is the installer’s sole responsibility to install and use this product in a manner that will not cause accidents, personal injury or property damage.
Please follow the installation instructions supplied. If installation is not correct, the unit may not perform at its designed potential. If in doubt, 
consult your local BEP Marine dealer. BEP Marine Limited disclaims all liability for any use of this product that may cause accidents, damage or 
be a violation of any laws.
Copyright © 2007 BEP Marine Limited. All rights reserved.