BENTHAM | TBD
Light. Measure. Excellence
3
t
Light. Measurement. Excellence.
Product Guide
TLS120Xe
High Power Tuneable
Light Source
(280-1100nm)
Страница 1: ...BENTHAM TBD Light Measure Excellence 3 t Light Measurement Excellence Product Guide TLS120Xe High Power Tuneable Light Source 280 1100nm...
Страница 2: ...hazardous UV and visible optical radiation emitted from this product Avoid eye and skin exposure to unshielded product Do not look at operating lamp Eye injury may result For further information plea...
Страница 3: ...subject the TLS120Xe to violent physical shock This may cause the lamp to explode Revision This section records the document revision details Date Version Notes January 2020 1 1 First release June 20...
Страница 4: ...the EU 6 1 5 Guarantee 7 TLS120Xe Description 8 2 1 Features Overview 8 2 2 Optical Design Overview 9 2 3 Description of Features 10 2 4 Installation Requirements 11 2 5 Shipped Components 11 2 6 Chas...
Страница 5: ...Guide v1 3 Light Measurement Excellence 4 1 Changing slits 20 4 1 1 Safety Notices 20 4 1 2 Overview 20 4 1 3 Procedure 20 4 2 1 Safety Notices 23 4 2 2 Overview 24 4 2 3 Lamp Replacement 24 4 2 4 Op...
Страница 6: ...Boulton Road Reading Berkshire RG2 0NH UK www bentham co uk For technical support http support bentham co uk T 44 0 118 975 1355 option 2 For sales support sales bentham co uk T 44 0 118 975 1355 opti...
Страница 7: ...tham with full details of the problem including model number and serial number of the instrument involved After receiving the above information Bentham will issue an RMA reference number and provide s...
Страница 8: ...operation of short arc xenon lamp ensures high beam power Continuous tuning A concave grating monochromator provides narrow bandwidth and high wavelength agility giving you the freedom to select the w...
Страница 9: ...ng 380 nm blaze wavelength is mounted on an on axis rotating turret driven by stepper motor having a drive resolution of 0 5 arcsec per step The grating spectrally disperses the broadband optical inpu...
Страница 10: ...ciprocal Dispersion nm mm 2 70 Slit Width mm Bandwidth nm 0 74 5 1 48 10 2 96 20 5 92 40 Table 1 Bandwidth of TLS120Xe 2 3 Description of Features TLS120Xe Iris diaphragm Main switch Lamp power switch...
Страница 11: ...pair 10nm bandwidth SA FSP 2 96 Slit pair 20nm bandwidth SA FSP 5 92 Slit pair 40nm bandwidth Fibres SMA 1500 1000 adaptor 45937 SMA fibre 1m long 1 5mm dia FIBRE UV 4 4 1000 adaptors 45936 46888 UV f...
Страница 12: ...ards due to non coherent optical radiation 280 nm 1100 nm emitted from the output aperture Rear Safety label stating the AC voltage and current ratings of the TLS120Xe Rear Environmental label indicat...
Страница 13: ...ours 100W Lamp Option Lamp type 7 2A Operating Current 100W 14V Nominal lamp power and voltage 500 hours Optical Layout Configuration Constant Deviation Angle Focal length 120mm effective Opto Mechani...
Страница 14: ...n SCPI Electrical Mechanical Overall dimensions 300L x 460W x 185H mm Weight 8 8 kg Power supply 100 240V AC 50 60 Hz Line fuse 5A slow blow rated 250 VAC Mains supply voltage fluctuations Up to 10 of...
Страница 15: ...ielding Blue light CAUTION Possibly hazardous optical radiation emitted from this product Do not stare at operating lamp May be harmful to the eye Retinal thermal Infrared eye NOTICE IR emitted from t...
Страница 16: ...age the lamp and lead to failure within a few hours Ensure that the TLS120Xe is locate in such a manner to ensure that the fans to the rear of the unit are not blocked Only use if connected to a safet...
Страница 17: ...Figure 3 Location of attachment screw to fibre adaptor 3 3 Powering on off the TLS120Xe Upon powering on the TLS120Xe the user will be presented with the following splash screen showing the product I...
Страница 18: ...nd its stability Figure 5 Display during normal operation It is recommended to give the unit a ten minute warm up time to allow the lamp output to stabilise To power off the TLS120Xe switch off direct...
Страница 19: ...0Xe is set to remote mode the target wavelength is set to 500nm the target filter set to the appropriate filter for 500nm and the monochromator moved to the target wavelength SYST REM MONO 500 MONO FI...
Страница 20: ...mination of the inside of the unit perform this operation in a dust free environment 4 1 2 Overview The bandwidth of the TLS120Xe is set by a pair of rectangular slits as detailed in table1 requiring...
Страница 21: ...t Measurement Excellence 3 Remove the two Torx TX 20 screws either side of the lid and use a flat bladed screwdriver to help prise off the lid and remove 4 The entrance slit can be seen toward the lam...
Страница 22: ...e cut metal aperture of the slit should face toward the diffraction grating for both entrance and exit slits 6 Insert new slits in correct orientation and push firmly down in slit housing 7 Replace co...
Страница 23: ...the lamp is turned off Mechanical Hazard Ensure unit is powered off before accessing Face mask Explosion risk wear full face mask throughout lamp change procedure Protective gloves Explosion risk wea...
Страница 24: ...ation of the inside of the unit perform this operation in a dust free environment Notice Do not touch quartz envelope with bare hands If quartz envelope is dirty wipe with alcohol soaked clean cloth 4...
Страница 25: ...ove that panel 4 Remove the two Torx TX 20 screws either side of the lid and use a flat bladed screwdriver to help prise off the lid and remove 5 Unplug the lamp shield safety switch undo the screws h...
Страница 26: ...irror and the seal protruding from the side of the xenon lamp attach the screw terminal to the tip of the lamp opposite end to the lamp seal taking care that it sits flush with the lamp 11 Place the l...
Страница 27: ...TLS120Xe monitor port fibre adaptors 1 Connect the fibre or liquid light guide to the monitor port of the TLS120Xe using the adaptors below 2 Switch the TLS120Xe on as well as the lamp if the lamp do...
Страница 28: ...s can be gained to the setting screws of the kinematic mount in which the xenon lamp is mounted Iteratively follow steps 6 and 7 until a maximum signal found 7 Focus adjust Use an 2mm AF Allen key to...