KYO 300-KYO100
PROGRAMMING
69
EVENT
STARTS WHEN...
ENDS WHEN...
2549
(1595)
Test
..the Control panel clock signals the Time
programmed on the
Teleservice
page
NOT ALLOWED!
2550
(1596-
1611)
2581
Reset on
partition no.
...
Alarms Reset
is requested using a User
Code and Keypad jointly enabled for the
Partition
NOT ALLOWED!
2582
(1612)
Reset on panel
...
Panel Reset
is requested
NOT ALLOWED!
Table 9
Spot Events (continued on next page)
EVENT
STARTS WHEN...
ENDS WHEN...
1229
(0659-
0674)
1260
Memory tamper
on partition no.
...the
Tamper alarm on partition no.
Event
occurs
...the Partition Resets
1261
(0675-
1174)
1760
Valid key no.
...a Key/Card is used at a Reader
...the Key/Card is removed from the Reader
1761
(1175-
1190)
1792
Key present on
reader no.
...a valid Key/Card is used at the Reader
...the Key/Card is removed from the Reader
1793
(1191-
1206)
1824
Valid Key on
Partition no.
... a valid Key/Card is inserted/held near a
Keypad
...the Key/Card is removed from the Reader
1825
(1207-
1222)
1856
Alarm stop on
partition no.
...a
Stop Alarms
request is made using a
User Code enabled for the Partition
...the Control panel exits the
Stop Alarms
phase
1857
(1223)
Alarm stop on
panel
…a
Panel Alarm Stop
request is made
...the Control panel exits the
Panel Alarm
Stop
phase
1858
(1224-
1359)
2137
Bypass zone no.
...the Zone is bypassed
...Zone no. is restored
2138
(1360-
1391)
2169
Bypass zone no.
– Via Radio
...the Wireless Zone is bypassed
...the Wireless Zone is restored
2170
(1392)
Telephone line
trouble
...the Telephone Line voltage is less than
3V for 45 seconds. If the
Telephone line
check
is disabled (refer to "Telephone"),
the event cannot be generated
...the Telephone Line voltage is higher
than 3V for 45 seconds
2171
(1393)
Error printer
…the Printer is either Disconnected; Im-
properly connected to the Printer interface;
OFF or Not in line (no paper, no ink/toner,
blocked, etc.)
…the trouble clears
2172
(1394)
Call queue full
...the 254th Telephone Action is queued
...there are no Telephone Actions in the
Call Queue
2173
(1395-
1426)
2236
Timer no.
...Timer no. switches ON (see
Timer
page) ... Timer no. switches OFF
2237
(1427-
1594)
2516
Real time of
zone no.
...the voltage (resistance) on Zone no. en-
ters the Alarm Range
...voltage (resistance) on Zone no. re-
stores to Standby Range
2517
...
2548
Real time of
zone no. – Via
Radio
...Wireless Zone no. is violated
...Wireless Zone no. returns to standby
Table 8
Generic Events — The Event numbers for
KYO 100
are those in brackets
(
....
)