Clear Fault/ Tamper (1.9)

This option will allow you to delete the Zone and Parti-
tion Fault and Tamper memories and set all Alarm sig-
naling devices to Standby.

+

If Alarm signal persists after a

Clear Fault/Tamp

command, the causes of persistent Alarms must
be cleared immediately.

1.

Press

A

or

B

to view the

Clear Fault/Tamp

option.

USER

1.9

Clear Fault/Tamp

2.

Press

ENTER

to select the option:

Clear Fault/Tamp

1=Fau._ 2=Tamp._

3.

Select

1

to delete Faults and/or

2

to delete Tam-

pers, then press

ENTER

to confirm:

Clear Fault/Tamp

Are you sure?

4.

Press

ENTER

to delete Faults and/or Tampers

(memories and active).

Clear Fault/Tamp

Done!

5.

Press

ESC

to step back to the User menu.

+

From “Stand-by status” after entering the User PIN,
if display shows Faults and/or Tamper, you can
press the

OFF

key: the keypad directly will manage

the previous procedure of “Clear Fault/Tamper”.

Program

n

ON/OFF Answering (2.1)

This option will allow you to turn ON/OFF the Answering
device. If the Answering device is ON, the Control panel
will answer incoming calls with a Voice message: your
installer has recorded the required Voice messages for
your system.

1.

Press

A

or

B

to view the

ON/OFF Answering

op-

tion.

USER

2.1

ON/OFF Answering

2.

Press:

Ø

ON

to Enable the Answering device;

Answering System

Enabled

Ø

OFF

to Disable the Answering device;

Answering System

Disabled

Ø

ESC

to step back to the User menu.

+

If the Answering device facility is enabled, an

*

will

be shown on the display directly above the

r

.

Absoluta Plus and Absoluta 630

OPERATIONS FROM LCD KEYPAD

47

Содержание Absoluta 630 4.10

Страница 1: ...Bentel Security Absoluta Plus 4 10 and Absoluta 630 4 10 Expandable Hybrid Control Panels User Manual Default User PIN 0001 00001 for Grade 3 Control Panels EN 50131 Grade 2 and Grade 3...

Страница 2: ...mp cloth without use any type of solvent Check the status of the connections and wires Check inside the panel there are no foreign bodies For other security system devices such as smoke detectors infr...

Страница 3: ...32 SMS Credit Balance 32 Received SMS 33 IP 33 APP 33 Screen Calibration 34 OPERATIONS FROM LCD KEYPAD 35 Adjusting Volume Brightness Contrast 36 Adjusting Buzzer Volume 36 Contrast Adjustment 36 Bri...

Страница 4: ...HONE OPERATIONS 65 Remote Access via Dialler mode 65 Remote Access via Answer mode 65 Typing in your User PIN 65 Entering Commands 66 Cancel Command 66 On Hook 66 Remote Talk Listen in 1 66 Zone Parti...

Страница 5: ...lus 48 ABS48P35 ABS 48 ABS P BAW35T12 Absoluta Plus 48 ABS48P50 ABS 48 ABS P BAW50T12 Absoluta Plus 128 ABS128P50 ABS 128 ABS P BAW50T12 Absoluta Plus 18 ABS18M35 ABS 18 ABS M BAW35T12 Absoluta Plus 4...

Страница 6: ...OPERATIONS FROM LCD KEYPAD Teleservice Request Not supported 1 Enable Disable Super User Not supported SMS Credit Balance Not supported READER OPERATIONS Automation and Access Control Not supported KE...

Страница 7: ...nd transmis sion of events to the central stations even after the partitions have been disarmed read Clear call queue to cancel the transmission of events Absoluta Plus and Absoluta 630 INTRODUCTION 7...

Страница 8: ...ital signals Digital Key An electronic control key with a random PIN selected from over 4 294 967 296 billion combina tions Display An alphanumeric screen on the LCD Keypads LCD Keypad A command keypa...

Страница 9: ...e temperature for more in formation read Temperature display on page 10 tap this icon to view the time and date 4 Signals Icon This area can show the following icons if the EN50131 option is disabled...

Страница 10: ...his key pressed for at least 10 seconds to re store the keypad This key blinks when the control panel receives an SMS read Received SMS for more information 15 Signals LED amber If option EN50131 is d...

Страница 11: ...eypad beeps and displays the icon about 4 seconds to signal an emergency situation Actions triggered by the Emergency Keys and Emergency Key labels depend on control panel pro gramming ask your instal...

Страница 12: ...led the visual and audio sirens signalling devices using the option Stop Alarms to re enable the signalling devices see Alarm Reset on page 22 The icon when the control panel is in service sta tus Whe...

Страница 13: ...obal option is NOT displayed if the installer has not programmed at least one stay arming Type A B C or D Labels of Stay Arming Modes can vary based on installer programming Any arming mode labels tha...

Страница 14: ...ter the Home Screen as described in Entering the Home Screen and press Disarm Entry Delay is also signalled audibly increasing in frequency when the alarm will go off in less than 10 seconds At the en...

Страница 15: ...n of time remaining You can postpone automatic arming by 1 hour as fol lows 1 Enter the Home Screen as described in Entering the Home Screen 2 Press More Time to postpone automatic arming by 1 hour or...

Страница 16: ...uta 630 control panel show the alarm status when they are on standby status Disarm partitions as described in Arming Disarming Partitions to end the alarm status The control panel carries on to transm...

Страница 17: ...ssed The display s left side shows the signals category Alarms Tampers Faults and Bypasses if a category has no signals in progress or memorised the relative key is not displayed the central part of t...

Страница 18: ...ng IP Super User 3 Enable Super User Keypad Backlight regulation of display bright ness Buzzer Control regulation of buzzer vol ume Picture Frame choice of photo for the Digital Frame Clock Mode displ...

Страница 19: ...the Home Screen Menu User This menu is ONLY accessible to Master Users This menu groups the following options PIN to set enable disable PINs Keys to disable enable keys and keyfobs Numbers to set Tel...

Страница 20: ...b Repeat PIN insertion and press to confirm if PIN numbers entered match the new PIN is memorised and the keypad returns to step 1 otherwise it goes back to step 4b PIN Duplicated If the existing PIN...

Страница 21: ...he Number to be changed the display s right side shows the Telephone Number selected 2 Press Edit to change the Telephone Number se lected Type in the desired number press dash to enter a long 4 secon...

Страница 22: ...and the transmission of events to the Central Stations will NOT be disabled see Alarm Status Clear the transmission of events to cancel the telephone actions If option EN50131 is ENABLED on the keypad...

Страница 23: ...selected Panel Output no 1 gener ally connected to the external siren is activated for about 3 seconds and Voice Messages and or Report ing Codes are sent to the Telephone Numbers as signed to the Gen...

Страница 24: ...ls and to export user PINs and Keys This option is disabled and CANNOT be enabled if the Installer option is disabled Press Enable to enable the option or Disable to disable the option n Answering Thi...

Страница 25: ...e disable the GSM Press Enable to enable the option of Disable to disable it n IP This option will allow you to enable disable the IP com munication Press Enable to enable the option or Disable to dis...

Страница 26: ...anguage Scrolling Text to disable the scrolling text Read the relevant section for more information The Keypad Menu can only be entered with a Mas ter User PIN n Backlight Screen Off after Set screen...

Страница 27: ...es selected are in a green frame Default all images are selected 3 Select the Slide Show tab to set how long you re main on each image Valid Values 2 5 10 20 30 45 seconds and 1 minute Default 2 secon...

Страница 28: ...in the green frame The image selected from the SD card is copied to the keypad memory so that the SD card can be re moved n Language Select the language to be used for keypad text When the keypad is f...

Страница 29: ...te it Actions The display s central part lists the Actions The status of Actions cannot be known a priori Press or to scroll the list then press On to acti vate the action or Off to deactivate it1 Inf...

Страница 30: ...the Bypassable option is enabled for that zone and status as shown in the following table Test the zone cannot cause alarms but its activi ties are memorised in the events log this can only be enabled...

Страница 31: ...events memorised in the Log The display s left side lists the events starting from the most recent It shows the day and month the event occurred the symbol t if an event has been restored the name of...

Страница 32: ...ay s central part shows SIM Number phone number of the SIM inserted in the GSM Module IMEI the GSM Module IMEI Provider name of the GSM operator Signal GSM signal intensity n SMS Credit Balance The Ab...

Страница 33: ...message wanted to read its content in the centre of the display 3 Press Delete to cancel the message 4 Press Yes to confirm and No to cancel n IP The central part of the display shows ABSSRV if the Ab...

Страница 34: ...he Home key for at least 3 seconds but less than 10 seconds 2 Press Screen Calibration 3 Follow instructions on the display before 10 sec onds have gone by or the keypad will go back to the previous s...

Страница 35: ...refer to OPERATING YOUR SYSTEM FROM A READER section 4 Proximity Reader sensitive field 5 Arrow scroll keys 6 Keys 7 Emergency Keys 8 Down flip 9 Label with the main operations Absoluta Plus and Absol...

Страница 36: ...key to adjust the inactive brightness 3a To increase the brightness press and hold down the A key until the desired brightness is reached 3b To reduce the brightness press and hold down the B key unt...

Страница 37: ...ult Date the top line shows the type of signal and the number of signal you are viewing followed by the total num ber of signals for that type the bottom line shows the description of the signal A fla...

Страница 38: ...first eight partitions 38 Expandable Hybrid Control Panels INITIAL STATUS DESCRIPTION A Away The system will turn ON the perimeter and internal zones of the respective Partition P Stay The system will...

Страница 39: ...r installer has set up the 3 super keys 1 2 and 3 you will be able to operate your system from the key pad without using PINs by press and hold key 1 key 2 or key 3 for at least 3 seconds an acoustic...

Страница 40: ...the common Partitions of the User PIN and the Keypad concerned Disarm under Duress PIN with Duress option en abled This command requires entry of a Duress PIN The Control panel will Disarm the Partiti...

Страница 41: ...is point you can do one of the following a Press the ENTER key and anyway perform the arm ing request of control panel b press the ESC key to cancel the arming request Based on the control panel funct...

Страница 42: ...n only en able disable a user not create a new one see pro cedure 2 5 Accessing the User Menu PIN ENTER Enter a valid User PIN then press ENTER to View if present the Troubles or Zone alarms Tamper ev...

Страница 43: ...n restore all Alarms and Tampers and delete all Alarm and Tamper memories n Extra Time Request 1 2 If the Auto arm option is enabled and the system is pro grammed to Arm automatically at a preset time...

Страница 44: ...aller 1 Press A or B to view the Clear call queue option USER 1 3 Clear call queue 2 Press ENTER to select the option Clear call queue Are you sure 3 Press ENTER to confirm Clear call queue Done 4 Pre...

Страница 45: ...n Outputs ON OFF 1 6 This option will allow you to silence the Alarm Outputs Sirens and turn the appliances sprinklers lights etc ON OFF 1 Press A or B to view the OutputOFF STOP option USER 1 6 Outp...

Страница 46: ...ssociated wireless device 1 Press A or B to view the Zone test option USER 1 8 Zone test 2 Press ENTER to select the option Zone test 1 Beep_ 2 Siren_ 3 Select the signal to activate in correspondence...

Страница 47: ...ser menu From Stand by status after entering the User PIN if display shows Faults and or Tamper you can press the OFF key the keypad directly will manage the previous procedure of Clear Fault Tamper P...

Страница 48: ...e press ESC to return to the User menu ON OFF PIN Transfer 4 Press ON to enable PIN Transfer PIN Transfer Enabled OFF to disable PIN Transfer PIN Transfer Disabled 5 Press ESC to return to the User Me...

Страница 49: ...e 2 Control Panels and 00001 for Grade 3 Control Panels The length of the PIN 4 5 or 6 digits and the program ming mode manual or automatic depend on the pro gramming of your panel ask the installer T...

Страница 50: ...6 Telephone Num 2 Press ENTER to select the option Tel N 3 Enter the Identification number of the required Phone number then press ENTER If you choose a Digital Dialler Phone Number the display shows...

Страница 51: ...ur new PIN 3b Press ENTER your new PIN PIN 04592 4b Save the PIN and press ENTER the Keypad stores the new PIN and returns to the User Menu PIN Duplicated If the existing PIN is entered at Step 4b the...

Страница 52: ...3 Press 1 to view the events from the last and skip to step 5 or press 2 to view the events from a specific date and time Data Time mm dd yy hh mm 4 Enter the required Data and Time to start to view...

Страница 53: ...ACTIVE sta tus when you activate it 5 Press OFF to bypass the zone Zone 001 Bypassed now ON to include the zone Zone 001 Included 6 Press ESC to go back to step 3 n GSM Module Status 3 3 This option a...

Страница 54: ...manually from right to left D to scroll the message manually from left to right ON to start automatic scrolling again from left to right 6 Press OFF to delete the message SMS 01 01 Text Delete SMS 7...

Страница 55: ...UTA INFO USER 3 6 ABSOLUTA INFO 2 Press ENTER to select the option v3 50IP UID 12345678 The line above of display shows the control panel ver sion v3 50IP in the example above the line below shows the...

Страница 56: ...56 Expandable Hybrid Control Panels...

Страница 57: ...the Key to per form the required operation PROXI2 Proximity Reader Figure 4d like the ECLIPSE2 Reader it has a sensitivity field where you must held the Key to perform the required opera tion Proximi...

Страница 58: ...ocking con ditions has been detected AMBER Light Indicator ON the system will arm in A Mode when you remove the Key from the Reader AMBER Light Indicator blinking A Mode arming blocking conditions has...

Страница 59: ...hen press OFF or hold another valid Key near the sensitive field of the Reader the Red light indicator turns OFF indicating the Partition disarming n Away Arm This operation will Arm all the Partition...

Страница 60: ...ON when you hold the Key near the Reader when you remove the Key from the Reader only the Partition n 1 arms in B Mode and the Green light indicator turns OFF n Disarm Patrol Keys with the Patrol opt...

Страница 61: ...inhibits the arming low bat tery through an LCD keypad and force the arm ing the external siren will emit a squawk to signal the arming Keyfobs enrolled on the Absoluta 630 control panel arm the parti...

Страница 62: ...e A Mode B 4 Mode A Mode B 5 Mode A Mode B 6 Mode A Mode B 7 Mode A Mode B 8 Mode A Mode B 9 Mode A Mode B 10 Mode A Mode B 11 Mode A Mode B 12 Mode A Mode B 13 Mode A Mode B 14 Mode A Mode B 15 Mode...

Страница 63: ...19 Mode A Mode B 20 Mode A Mode B 21 Mode A Mode B 22 Mode A Mode B 23 Mode A Mode B 24 Mode A Mode B 25 Mode A Mode B 26 Mode A Mode B 27 Mode A Mode B 28 Mode A Mode B 29 Mode A Mode B 30 Mode A Mo...

Страница 64: ...l turn ON All the system trouble conditions are signalled by the G LED Therefore if this LED turns ON you must access the View Signals mode for details The low wireless battery condition will be signa...

Страница 65: ...wering on page 24 and ON OFF Answering 2 1 on page 47 Do not use a telephone with a redial button to arm or disarm your system as this may put your system security at risk The control panel will answe...

Страница 66: ...Talk and Listen in modes press 1 Press 4 to reduce the remote microphone audio gain Press 5 to centre the remote microphone audio gain Press 6 to increase the remote microphone audio gain n Zone Part...

Страница 67: ...artition in Away mode 2 to Disarm the Partition 3 to Arm the Partition in Stay mode 4 to Arm the Partition in Stay with Zero Delay mode The partition status will be indicated by the following messages...

Страница 68: ...ll allow you to protect your system against unauthorized access If you Dis able a PIN via Telephone it cannot be used again until it is Re enabled via the User menu refer to PIN Programming 68 Expanda...

Страница 69: ...Absoluta Plus and Absoluta 630 TELEPHONE OPERATIONS 69...

Страница 70: ...5 21 6 22 7 23 8 24 9 25 10 26 11 27 12 28 13 29 14 30 15 31 16 32 Table 10 Events Controlled by Caller ID N Command String Event Partitions 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10...

Страница 71: ...wing SMS to the control panel s GSM number ABS E PIN ON OFF Command String Text PIN a User PIN enabled to manage the control panel by SMS ON OFF ON activates the event OFF deactivates the event Comman...

Страница 72: ...dditional text that can be used to assign a description to the command message and is ignored by the control panel The angle brackets should NOT be included in the message For example lets suppose you...

Страница 73: ...credit message will be forwarded periodically to the first number in the Phonebook You can check the credit balance also from a key pad for more information see SMS Credit Bal ance on page 32 and Modu...

Страница 74: ...96 11 54 97 12 55 98 13 56 99 14 57 100 15 58 101 16 59 102 17 60 103 18 61 104 19 62 105 20 63 106 21 64 107 22 65 108 23 66 109 24 67 110 25 68 111 26 69 112 27 70 113 28 71 114 29 72 115 30 73 116...

Страница 75: ...know the UID of the Control Panel See OPERATIONS FROM TOUCH KEYPAD GSM IP APP OPERATIONS FROM LCD KEYPAD View ABSOLUTA INFO 3 6 Arming block conditions The Table 13 on page 76 shows the conditions tha...

Страница 76: ...Yes Display Mess No Fast Blink No Siren No Siren No Yes INCERT Display Mess No Fast Blink No Siren No Siren No No Display Mess No Fast Blink No Siren No Siren No No Action Yes Display Mess No Fast Bli...

Страница 77: ...ent No Message No Message N A Voice Mess No SMS Mess No No Dedicated Event No Message No Message No Voice Mess No SMS Mess No No Dedicated Event No Message No Message No Voice Mess No SMS Mess No No D...

Страница 78: ...s No Fast Blink No Siren No Siren No Yes INCERT Display Mess No Fast Blink No Siren No Siren No No Display Mess F LED ON Yes Siren Yes Siren Yes System Tamper in Memory Yes Display Mess Yes6 LED ON Ye...

Страница 79: ...Event No Message No Message N A Voice Mess F SMS Mess F Yes None Yes Message Yes6 Message Yes6 Voice Mess Yes SMS Mess Yes No None Yes6 Message Yes Message No Voice Mess Yes SMS Mess No No Dedicated E...

Страница 80: ...ller PS1 NO batt Switching power supply of the Power station No 1 2 3 or 4 does not work Call the Installer PS1 bat charg The Output voltage of the Switching power supply of the Power station No 1 2 3...

Страница 81: ...be reset 3 Main Receiv Lost The panel CANNOT transmit the events to the primary receiver If the MainRec OFF CMS event is also present in the event log the central station has stopped re mote monitori...

Страница 82: ...82 Expandable Hybrid Control Panels...

Страница 83: ...Absoluta Plus and Absoluta 630 APPENDIX 83...

Страница 84: ...d trademarks Unauthorized use is strictly prohibited BENTEL SECURITY S r l Via Gabbiano 22 Zona Ind S Scolastica 64013 Corropoli TE Italy Tel 39 0861 839060 Fax 39 0861 839065 infobentelsecurity tycoi...

Отзывы: