Learning Advanced Features
142
890054-00-00
GM2 Series VFD
Press Regeneration Prevention
Press regeneration prevention is used during press operations to prevent braking during
the regeneration process. When motor regeneration occurs during a press operation, the
motor operating speed automatically increases to avoid the regeneration zone.
Group Code
Name
Setting
Setting Range
Unit
Ad
74
Selection of regeneration
evasion function for press
0 No
0
–
1
-
75
Voltage level of regeneration
evasion motion for press
350 V
200 V 300
–
400 V
V
700 V
400 V 600
–
800 V
76
Compensation frequency limit
of regeneration evasion
1.00
(Hz)
0.00
–
10.00 Hz
Hz
77 Regeneration evasion P gain
50.0 (%)
0
–
100%
%
78 Regeneration evasion I gain
500 (ms)
20
–
30000 ms
ms
Press Regeneration Prevention Setting Details
Code and
Features
Description
Ad.74 RegenAvd Sel
Frequent regeneration voltage from a press load during constant
motor speed operation may force excessive work on the brake unit
which may damage or shorten the brake life. To prevent this
situation, set Ad.74 (RegenAvd Sel) to 1 (Yes) to control DC link
voltage and disable the brake unit operation.
Ad.75 RegenAvd
Level
Set the DC Link voltage level to activate Regen Avoidance.
Ad.76 CompFreq
Limit
Set a frequency limit above operating frequency during Regen
Avoidance.
Ad.77 RegenAvd
Pgain, Ad.78
RegenAvd Igain
Set the P gain and I gain in the DC link voltage suppress PI
controller while in Regen Avoidance.
Содержание RSi GM2 Series
Страница 2: ...ii...
Страница 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Страница 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Страница 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Страница 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...