Q7T3(AUO Panel) LCD Monitor Service Guide
Alignment Procedure
3
Write Reddish(5800K) B-Gain Data to NVRAM
AA
5E
Data
checksum
Write User R-Gain Data to NVRAM
AA
6C
Data
checksum
Write User G-Gain Data to NVRAM
AA
6D
Data
checksum
Write User B-Gain Data to NVRAM
AA
6E
Data
checksum
Read Bluish(9300K) R-Gain data from NVRAM
A3
3C
XX
checksum
Read Bluish(9300K) G-Gain data from NVRAM
A3
3D
XX
checksum
Read Bluish(9300K) B-Gain data from NVRAM
A3
3E
XX
checksum
Read sRGB(6500K) R-Gain data from NVRAM
A3
4C
XX
checksum
Read sRGB(6500K) G-Gain data from NVRAM
A3
4D
XX
checksum
Read sRGB(6500K) B-Gain data from NVRAM
A3
4E
XX
checksum
Read Reddish(5800K) R-Gain data from NVRAM
A3
5C
XX
checksum
Read Reddish(5800K) G-Gain data from NVRAM
A3
5D
XX
checksum
Read Reddish(5800K) B-Gain data from NVRAM
A3
5E
XX
checksum
Read User R-Gain data from NVRAM
A3
6C
XX
checksum
Read User G-Gain data from NVRAM
A3
6D
XX
checksum
Read User B-Gain data from NVRAM
A3
6E
XX
checksum
Change Color Temperature to Bluish
CC
1
XX
checksum
Change Color Temperature to sRGB
CC
2
XX
checksum
Change Color Temperature to Reddish
CC
3
XX
checksum
Change C/T to User
CC
4
XX
checksum
User mode to factory mode
1A
5A
XX
checksum
Auto Color (Offset1, Offset2, Gain)
1B
5A
XX
checksum
Factory mode to User mode
1E
5A
XX
checksum
Clear user area data
1F
5A
XX
checksum
Off burn in mode
CE
2
XX
checksum
Change Language Setting
66
0~7
XX
checksum
Note A: Byte4(Checksum) = Byte1 + Byte2 + Byte3
Note B: Data = The value write to MCU
Note C: XX = don't care, any value(<=0xFF).
Note D: The Byte-2 definition of “Change Language Setting” is as below,
0=DE, 1=EN, 2=ES, 3=FR, 4=IT, 5=JA, 6=
繁中
, 7=
簡中
When PC Host sends 0x7D command to MCU, MCU must return as following (2 bytes)
Return Code
R-Byte1
R-Byte2
Checksum error code
FC
AA
Normal return code
the above Byte3 (/data)
FC
If normal return code is exact FCh
FC
CF
Содержание Q7T3-FP737S
Страница 8: ...Q7T3 FP737S Dual function LCD Monitor Service Guide Alignment Procedure 8 Confidential...
Страница 48: ......
Страница 49: ......
Страница 60: ...Q7T3 AUO Panel LCD Monitor Service Guide Alignment Procedure 6 b LVDS Cable with tape c Lamp wire with clip...
Страница 62: ...Q7T3 AUO Panel LCD Monitor Service Guide Alignment Procedure 8 f Spacer g Signal cable with clip...
Страница 63: ...Q7T3 AUO Panel LCD Monitor Service Guide Alignment Procedure 9 h Bracket Cover i Plug under AC socket...
Страница 67: ...Q7T3 AUO Panel LCD Monitor Service Guide Alignment Procedure 13 b C603 C604 L606 L607 c C615...
Страница 91: ......
Страница 92: ......
Страница 110: ...Q7T3 CPT Panel LCD Monitor Service Guide Alignment Procedure 5 Fig 1 Factory Mode On Fig 2a Burn In Mode Button...
Страница 111: ...Q7T3 CPT Panel LCD Monitor Service Guide Alignment Procedure 6 Fig 2b Burn In Mode ON 2 Wire Dressing a RSDS Cable...
Страница 113: ...Q7T3 CPT Panel LCD Monitor Service Guide Alignment Procedure 8 d Al Foil Mylar on the shielding cover e Spacer...
Страница 114: ...Q7T3 CPT Panel LCD Monitor Service Guide Alignment Procedure 9 f Signal cable with clip g Bracket Cover...
Страница 115: ...Q7T3 CPT Panel LCD Monitor Service Guide Alignment Procedure 10 h Plug under AC socket i Main Grounding Wire...
Страница 118: ...Q7T3 CPT Panel LCD Monitor Service Guide Alignment Procedure 13 3 Add Glue a C605 b C603 C604 L606 L607...
Страница 119: ...Q7T3 CPT Panel LCD Monitor Service Guide Alignment Procedure 14 c C615...