background image

Menu settings

22

Menu settings

To modify the parameters in the menu, you need to exit the menu before you can save it 

by power off.

Menu control key

1. MENU: Enter/exit OSD menu or return to previous menu.
2. HOME: Go to the next menu.
3.

/

: Select controls.

4.

/

Modify parameter values

.

Menu interface

Содержание DVY23

Страница 1: ...DVY23 Full HD Camera User Manual...

Страница 2: ...ontents thereof without obligation to notify any person of such revision or changes Copyright Copyright 2020 BenQ Corporation All rights reserved No part of this publication may be reproduced transmit...

Страница 3: ...ation instructions 8 Product interface 8 Interface wiring 9 Bracket mount 9 Product overview 13 Remote control 18 Key instructions 18 Applications 20 Menu settings 22 Menu control key 22 Menu interfac...

Страница 4: ...eaming media 34 Software upgrade 36 Serial communication control 37 VISCA protocol list 37 Product information 54 Specifications 54 Dimensions 56 Maintenance and troubleshooting 57 Maintenance 57 Trou...

Страница 5: ...o the following operations Do not grasp the lens barrel with your hand while moving the camera Move the camera by holding the bottom with both hands or one hand Whether electrified or not do not shake...

Страница 6: ...ranty Electric safety Installation and use of this product must strictly comply with the national and local electrical safety standards Do not use power adapters beyond the specifications of the power...

Страница 7: ...netic interference The electromagnetic field at a specific frequency may affect the local image The product is Class A product Radio interference may occur in the home environment and users need to ta...

Страница 8: ...ase Rotary dial switch Remote control receiver light RS232 input Infrared reception RS232 output Tripod screw hole RS422 input compatible with RS485 Network LAN Power over Ethernet HDMI output Power I...

Страница 9: ...self check is completed 2 The default address of the remote control is 1 the menu is restored to the factory default and the address of the remote control is restored to 1 Bracket mount Bracket can o...

Страница 10: ...Installation instructions 10...

Страница 11: ...Installation instructions 11 2 Ceiling mount steps...

Страница 12: ...Installation instructions 12...

Страница 13: ...ed accessories are included RS 232 Interface 1 RS 232 interface Configuration Standard Optional Accessory Power adapter 1 Upside down ceiling mounting bracket USB3 0 cable 1 Wall mounting bracket RS23...

Страница 14: ...eady GND Signal ground TXD Transmit Data IR OUT IR Commander Signal GND Signal ground NC No Connection No Port Definition DCD Data Carrier Detect DSR Data Set Ready RXD Receive Data RTS Request to Sen...

Страница 15: ...roduct overview 15 4 VISCA networking mode is as follows Product cascade connection Method The product has RS232 input and output interface which can be cascaded following the instructions shown above...

Страница 16: ...1080P50 9 1080I59 94 2 1080I60 A 1080P29 97 3 1080I50 B 720P59 94 4 1080P30 C 720P29 97 5 1080P25 D 6 720P60 E 7 720P50 F video format to be set on the menu Remember to reboot the camera to take effe...

Страница 17: ...able auto focusing Low Noise and High SNR Low Noise CMOS effectively ensure high SNR of camera video Advanced 2D 3D noise reduction technology is also used to further reduce the noise while ensuring i...

Страница 18: ...reset 0 is set and there is no operation within 12 seconds the camera head will automatically point to the specified preset 0 position Camera Address Selection Select the camera address to be controll...

Страница 19: ...tion Functions 1 Clear all presets 2 6 Restore factory defaults 3 9 Flip switch 4 Auto Enter the aging mode 5 3 Menu set to Chinese 6 4 Menu set to English 7 Manual Restore the default user name passw...

Страница 20: ...back to the middle position Press and hold the key and the pan tilt will keep running from slow to fast until it runs to the end point the pan tilt running stops as soon as the key is released 3 Pres...

Страница 21: ...us key Valid only in manual focus mode Auto Focus Yes Manual Focus Yes Press and hold the key then the action of focus will continue and stops as soon as the key is released 6 Address Setting F1 Camer...

Страница 22: ...e parameters in the menu you need to exit the menu before you can save it by power off Menu control key 1 MENU Enter exit OSD menu or return to previous menu 2 HOME Go to the next menu 3 Select contro...

Страница 23: ...n menu In the normal working mode press the MENU key to display the menu then use the scroll arrow to point at or highlight the selected items No Name Descriptions Language Chinese English Setup Enter...

Страница 24: ...rsion setting Restore Default Enter Reset setting Select For selecting menu Change Value For modify parameters MENU Back Press MENU to return HOME OK Press HOME to confirm No Name Descriptions Protoco...

Страница 25: ...re setting Move the pointer to Exposure in the main menu then click the HOME key and enter EXPOSURE as follow No Name Descriptions Exposure Enter Exposure setting Color Enter Color setting Image Enter...

Страница 26: ...e in Auto Iris priority Brightness priority mode DRC Off 1 8 Shutter Priority 1 25 1 30 1 50 1 60 1 90 1 100 1 120 1 180 1 250 1 350 1 500 1 1000 1 2000 1 3000 1 4000 1 6000 1 10000 only available in...

Страница 27: ...as follow Hue 0 14 AWB Sensitivity High Middle Low No Name Descriptions Brightness 0 14 Contrast 0 14 Sharpness 0 15 Flip H On Off Flip V On Off B W Mode Color Black White Gamma Default 0 45 0 50 0 55...

Страница 28: ...ing Move the pointer to Noise reduction in the main menu then click the HOME key and enter NOISE REDUCTION as follow No Name Descriptions Focus Mode Auto Manual One push AF Zone All Top Center Bottom...

Страница 29: ...er P T Z as follow No Name Descriptions Depth of field Only effective for remote control On Off When zoom in the PT control speed by remote control will become slow Zoom speed Set the zoom speed for r...

Страница 30: ...nter to Version in the main menu then click the HOME key and enter VERSION as follow 1080P60 Downward Compatibility Exit the menu after modifying the parameter to save it after power off No Name Descr...

Страница 31: ...Options Yes No after restoring default the video format won t be restored If the address of the former remote control is not 1 but another one from 2 3 4 the corresponding camera address will restore...

Страница 32: ...ute Internet Protocol Version 4 TCP IPv4 and enter the attributes window of Internet Protocol Version 4 TCP IPv4 Click Advanced to enter the advanced TCP IP settings and add IP and IPv4 to the IP addr...

Страница 33: ...ng camera the login page will appear Playback plug in is not installed please download and install Click on this message download and install MRWebXinstall exe according to information prompts If a wa...

Страница 34: ...ive xxx If the default IP address of the camera is 192 168 5 163 the way to obtain the RTSP video stream is as follows rtsp 192 168 5 163 554 live av0 av0 Main stream rtsp 192 168 5 163 554 live av1 a...

Страница 35: ...etwork otherwise the connection to the server will be unsuccessful Host address Server address either domain name or IP address Host Port Server Default Port Number Stream name live test for example l...

Страница 36: ...Configuration System Configuration Software Upgrade to enter the following interface 3 Click Browse to select the upgrade file mrg and double click then click the Upgrade button to upgrade automatical...

Страница 37: ...ll be back to that position after initialization At this point the user can control the camera by the serial commands VISCA protocol list Camera return command z camera address 8 Ack Completion Messag...

Страница 38: ...04 07 03 FF Tele Variable 8x 01 04 07 2p FF p 0 low 7 high Wide Variable 8x 01 04 07 3p FF Direct 8x 01 04 47 0p 0q 0r 0s FF pqrs Zoom Position CAM _Focus Stop 8x 01 04 08 00 FF Far Standard 8x 01 04...

Страница 39: ...AA 03 FF CAM_WB Auto 8x 01 04 35 00 FF 3000K 8x 01 04 35 01 FF 4000k 8x 01 04 35 02 FF One Push mode 8x 01 04 35 03 FF 5000k 8x 01 04 35 04 FF Manual 8x 01 04 35 05 FF 6500k 8x 01 04 35 06 FF 3500K 8...

Страница 40: ...4 00 00 0p 0q FF pq B Gain CAM_AE Full Auto 8x 01 04 39 00 FF Automatic Exposure mode Manual 8x 01 04 39 03 FF Manual Control mode Shutter priority 8x 01 04 39 0A FF Shutter Priority Automatic Exposur...

Страница 41: ...ition CAM_Bright Reset 8x 01 04 0D 00 FF Bright Setting Up 8x 01 04 0D 02 FF Down 8x 01 04 0D 03 FF Direct 8x 01 04 4D 00 00 0p 0q FF pq Bright Position CAM_ExpComp On 8x 01 04 3E 02 FF Exposure Compe...

Страница 42: ...Light Mode ON 8x 01 04 2D 01 FF Low Light Mode Setting OFF 8x 01 04 2D 00 FF CAM_Flicker OFF 8x 01 04 23 00 FF OFF 50HZ 8x 01 04 23 01 FF 50HZ 60HZ 8x 01 04 23 02 FF 60HZ CAM_Aperture Reset 8x 01 04 0...

Страница 43: ...era ID 0000 to FFFF SYS_Menu On 8x 01 04 06 06 02 FF Turn on the menu screen Off 8x 01 04 06 06 03 FF Turn off the menu screen IR_Receive On 8x 01 06 08 02 FF IR remote commander receive On Off Off 8x...

Страница 44: ...V 8x 01 04 A4 02 FF Flip HV 8x 01 04 A4 03 FF CAM_VideoSystem Set camera video system 8x 01 06 35 00 0p FF P 0 E Video format 0 1080P60 1 1080P50 2 1080i60 3 1080i50 4 720P60 5 720P50 6 1080P30 7 108...

Страница 45: ...nRight 8x 01 06 01 VV WW 02 02 FF Stop 8x 01 06 01 VV WW 03 03 FF Pan_tiltDrive Absolute Position 8x 01 06 02 VV WW 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF VV Pan speed 0x01 low speed to 0x18 high speed WW Tilt sp...

Страница 46: ...0q 0r 0s FF pqrs Zoom Position CAM_FocusAFModeInq 8x 09 04 38 FF y0 50 02 FF Auto Focus y0 50 03 FF Manual Focus y0 50 04 FF One Push mode CAM_FocusPosInq 8x 09 04 48 FF y0 50 0p 0q 0r 0s FF pqrs Focu...

Страница 47: ...50 0B FF 7000K CAM_AWBSensitivityInq 8x 09 04 A9 FF y0 50 00 FF Low y0 50 01 FF Normal y0 50 02 FF High CAM_RGainInq 8x 09 04 43 FF y0 50 00 00 0p 0q FF pq R Gain CAM_BGainInq 8x 09 04 44 FF y0 50 00...

Страница 48: ...FF y0 50 02 FF On y0 50 03 FF Off CAM_WDRStrengthInq VISCA has no DRCcommand leverage WDR to adjust DRC parameter 8x 09 04 51 FF y0 50 0p FF p WDR Strength CAM_NRLevel 2D Inq 8x 09 04 53 FF y0 50 0p F...

Страница 49: ...0p FF p Gamma ID IR_ReceiveInq 8x 09 06 08 FF y0 50 02 FF On y0 50 03 FF Off CAM_BrightnessInq 8x 09 04 A1 FF y0 50 00 00 0p 0q FF pq Brightness Position CAM_ContrastInq 8x 09 04 A2 FF y0 50 00 00 0p...

Страница 50: ...E 720P29 97 Pan tiltMaxSpeedInq 8x 09 06 11 FF y0 50 ww zz FF ww Pan Max Speed zz Tilt Max Speed Pan tiltPosInq 8x 09 06 12 FF y0 50 0w 0w 0w 0w 0z 0z 0z 0z FF wwww Pan Position zzzz Tilt Position Co...

Страница 51: ...Preset ID SUM Call Preset 0xFF Address 0x00 0x07 0x00 Preset ID SUM Query Pan Position 0xFF Address 0x00 0x51 0x00 0x00 SUM Query Pan Position Response 0xFF Address 0x00 0x59 ValueHigh Byte ValueLow...

Страница 52: ...0x40 0x00 0x00 0xAF XOR Focus Far 0xA0 Address 0x01 0x00 0x00 0x00 0xAF XOR Focus Near 0xA0 Address 0x02 0x00 0x00 0x00 0xAF XOR Set Preset 0xA0 Address 0x00 0x03 0x00 Preset ID 0xAF XOR Clear Preset...

Страница 53: ...Serial communication control 53 Query Zoom Position Response 0xA0 Address 0x00 0x5D Value High Byte ValueLow Byte 0xAF XOR Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8...

Страница 54: ...480P30 640 360P30 640 480P30 320 176P30 Slave stream YUY2 NV12 supports 640 360P30 640 480P30 320 176P30 MJPEG H 264 supports 1920 1080P30 1280 720P30 1024 576P30 960 540P30 800 448P30 720 480P30 640...

Страница 55: ...SRT Support remote upgrade remote restart remote reset Control interface RS232 RS422 RS485 Control protocol VISCA Pelco D Pelco P Baud Rate 115200 9600 4800 2400bps Power interface HEC3800 outlet DC12...

Страница 56: ...Product information 56 Dimensions Unit mm...

Страница 57: ...e equipment is firm or not Check whether there are vibrating machines or objects around the equipment 4 Remote control is uncontrollable Check whether the remote control address is set to 1 controllab...

Страница 58: ...58 Open Start in the computer select Run and enter cmd click OK and then open the computer DOS command window and enter Ping 192 168 5 163 Press the Enter key and the information appears as follows D...

Отзывы: