5.7 Temperature measurement
Operation
5235 / 05/2022 en
BENNING MM 7-2
38
5.7
Temperature measurement
Requirements
• Please observe the requirements for measuring [
• Temperature sensor
The temperature sensor must be approved for the device (e. g. wire temperature sensor of
type K included in the scope of delivery) and be in a technically perfect and operationally
safe condition.
Figure 13:
Temperature measurement
Procedure
1. Set the rotary switch of the device to switch position “Temperature measurement”.
2. Press the blue “Function” key to set the temperature unit (°C or °F). The selected
temperature unit is shown on the digital display. Please note that you can optionally disable
a temperature unit [
3. Connect the temperature sensor to the device observing correct polarity and make sure that
it is firmly connected.
– Negative pole into the COM jack
– Positive pole into the jack for temperature measurement
4. Position the contact point (end of the wire temperature sensor) at the measuring point.
5. Wait until the measured value on the digital display has stabilised and read it.