background image

12

MENU

FUNCTION

ON-OFF

(Default)

MEMO

LOGIC

In 1

Presetting of the channel status (normally open/ normally closed).
IST: Channel preset as “Gate input status” See section “Gate input status”.
NO: Channel preset for a NO (normally open) input.
NC: Channel preset for a NC (normally closed) input.

(NO)

In 2

Presetting of channel 2 status Same options as channel 1.

----

-------

In 6

Presetting of channel 6 status Same options as channel 1.

MENU

FUNCTION

RADIO

add

OUT 1

Outputs 1/2/3/4 can be activated by a radio transmitter.

Select the desired output, the receiver awaits for (

 Push

 ) a transmitter code to be as-

signed to the channel.
Press the transmitter key to be assigned to the output.

If the code is valid, it will be memorised and 

OK

 is displayed on the monitor.

If the code is not valid, the message 

Err

 is displayed.

OUT 2

OUT 3

OUT 4

code

roll

The reception of variable transmitter codes is enabled/disabled (default ON).

bYou

The reception of BYOU transmitter is enabled/disabled (default ON).

fiX

The reception of programmable transmitter is enabled/disabled (default ON).

CLR

If this function is selected, the receiver waits for (

 Push

 ) a transmitter code to be erased from memo-

ry.

If the code is valid, it will be erased and 

OK

 is displayed on the monitor.

If the code is not valid, or it is not in memory, the message 

Err

 is displayed.

res

The receiver memory is totally erased. When the wording 

PUSH

 is displayed, the operation must be 

confirmed.

(During reset, the 

RES

 wording flashes. At end of reset, 

OK

 is displayed).

MENU

FUNCTION

tar

Measurement of the current consumption in standby (powered control unit with stopped motor).

The operation needs to be confirmed. During measurement, the wording 

MIS

 flashes.

At conclusion of the operation, the system returns to TAR Menu. 
The value is memorised and used by ESA-BASIC as reference of consumption in stand-by, for the 
counting of the TOFF time. In order not to have an incorrect reading, the measurement shall be at 
motor stopped.

iout

The value (expressed in Amperes) of the output current that ESA-BASIC supplies to the control unit 
is displayed.

res

RESET. WARNING!: Restore ESA-BASIC to default values.

With the first pressure of the <PG> push button, the message 

PUSH

 is displayed. If the push button is 

pressed again, the message 

PROG

 is displayed and then 

OK

 is displayed at end of reset. 

Note: The transmitter codes are not erased from the receiver.

Intelligent Security & Fire Ltd.

Содержание ESA BASIC

Страница 1: ...L8542643 06 2010 rev 0 ESA BASIC UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 2: ...5 14 13 12 11 10 23 22 21 20 19 18 17 16 OUT 1 COM IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 OUT 2 24 25 26 NO COM NC OUT 3 OUT 4 OUT 5 OUT 6 85 230Vac 50 60Hz RADIO F1 8 9 7 6 5 4 3 2 1 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 3: ...11 10 21 20 19 18 17 16 24 25 26 NO COM NC 85 230Vac 50 60Hz 8 9 7 6 5 4 3 2 1 PHOT OPEN CLOSE PED P P COM PHOT OPEN CLOSE PED P P COM ESA BASIC 23 22 ESEMPIO DI COLLEGAMENTO I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 4: ...t a conductive mass of the ground according to the regulations in force The electrical installation and the operating logic must comply with the regulations in force The leads fed with different voltages must be physically separate or they must be suitably insulated with additional insulation of at least 1 mm The leads must be secured with an additional fixture near the terminals During installati...

Страница 5: ...er a presettable time the system returns to the SLEEP mode WIRE DIAGRAM The electric connections shown in Fig 1 are described in the following table Terminals Function Description 1 2 Mains power supply Input mains power supply ESA BASIC accepts power supply voltages ranging from 85 to 260 VAC 3 COM Common to all control inputs 4 COM IN 1 Input contact of command 1 It is configurable for NO NC or ...

Страница 6: ... this allows to return to the upper menu without making any changes To speed up the increase decrease of values keep key or key pressed After waiting 30 seconds the control unit exits the programming mode and switches the display off PARAMETERS LOGICS AND SPECIAL FUNCTIONS The single functions available in the control unit are described in the following table MENU FUNCTION MIN MAX Default MEMO PAR...

Страница 7: ...h a transmitter code to be erased from memo ry If the code is valid it will be erased and OK is displayed on the monitor If the code is not valid or it is not in memory the message Err is displayed res The receiver memory is totally erased When the wording PUSH is displayed the operation must be confirmed During reset the RES wording flashes At end of reset OK is displayed MENU FUNCTION tar Measur...

Страница 8: ... of ESA BASIC The antenna of the control unit should be therefore disconnected and connected to the special inputs 22 23 The NC contacts of a safety edge shall be in any case connected to the special input of the control unit GATE STATUS INPUT One or more inputs can be preset in GATE STATUS INPUT mode In the input preset in this way a NO contact can be connected such as the SCA output contact of t...

Отзывы: