background image

11

BYPASS MODE

The “Bypass” mode is entered by pressing keys + and – simultaneously.

ON: 

 

ESA BASIC keeps the control unit connected to it always on. In this way, parameters and logics of the control unit 

can be preset, thus avoiding that the control unit enters the SLEEP mode.
N.B.: when the BYPASS mode is ON, the wording “ON” is displayed.

OFF: 

  ESA BASIC works regularly.

HOW TO PROGRAMME

The programming of the various functions of the control unit is carried out by using the LCD display on the control unit and 
presetting the desired values in the programming menus described hereunder.

USE OF THE PROGRAMMIN PUSH BUTTONS

Press OK to access the Main Menu (PAR>>LOG>>RADIO>>...) that can be selected by pressing keys + and -.
Select the Main Menu by pressing <OK> to access the desired Function Menu.

t5PTDSPMMUIF'VODUJPO.FOVGSPNUPQUPCPUUPNQSFTTUIFLFZ
t5PTDSPMMUIF'VODUJPO.FOVGSPNCPUUPNUPUPQQSFTTUIFLFZ
t#ZQSFTTJOHUIF0,LFZBDDFTTJTFOBCMFEUPBOZQPTTJCMFQSFTFUUJOHUPCFNPEJmFE
t5IFQSFTFUWBMVFTDBOCFDIBOHFECZQSFTTJOHBOELFZT
t*G0,JTQSFTTFEBHBJOUIFWBMVFJTQSPHSBNNFEBOE0,JTEJTQMBZFE

See section “Programming Example”.

NOTE: 

If keys <+> and <-> are pressed simultaneously from a Function Menu, this allows to return to the upper menu without 
making any changes.
To speed up the increase/decrease of values, keep key <+> or key <-> pressed.
After waiting 30 seconds, the control unit exits the programming mode and switches the display off.

PARAMETERS, LOGICS AND SPECIAL FUNCTIONS

The single functions available in the control unit are described in the following table.

MENU

FUNCTION

MIN-MAX

(Default)

MEMO

PARAMETERS

toff

Self-switching  off  time:  when  the  preset  time  has  elapsed,  if  the  system  is 
still in standby mode (powered control unit with motor stopped), ESA cuts off 
power to the control unit.
If  one  of  the  N.C.  inputs  is  kept  open  (e.g.  photocell  obscured),  the  self-
switching  off  time  will  not  be  calculated  until  the  input  recovers  its  regular 
operating mode.

N.B.: preset a TOFF higher than the TCA time preset in the control unit.

10-3600 sec

(60)

STD1

Start Delay channel 1: delay between the activation of input 1 and its replication 
OUT 1 when the control unit is in SLEEP mode (this delay is the time required 
for the control unit to switch on and being able to receive a control signal sent 
by ESA).

0.1-15.0 sec 

(2,0)

STd2

Start Delay channel 2:

----

-------

STd6

Start Delay channel 6:

tch1

The switch time of the channel 1 relay is preset.

0.1-90.0 sec 

(1,0)

TCH2

The switch time of the channel 2 relay is preset.

----

-------

TCH6

The switch time of the channel 6 relay is preset.

Intelligent Security & Fire Ltd.

Содержание ESA BASIC

Страница 1: ...L8542643 06 2010 rev 0 ESA BASIC UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 2: ...5 14 13 12 11 10 23 22 21 20 19 18 17 16 OUT 1 COM IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 OUT 2 24 25 26 NO COM NC OUT 3 OUT 4 OUT 5 OUT 6 85 230Vac 50 60Hz RADIO F1 8 9 7 6 5 4 3 2 1 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 3: ...11 10 21 20 19 18 17 16 24 25 26 NO COM NC 85 230Vac 50 60Hz 8 9 7 6 5 4 3 2 1 PHOT OPEN CLOSE PED P P COM PHOT OPEN CLOSE PED P P COM ESA BASIC 23 22 ESEMPIO DI COLLEGAMENTO I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 4: ...t a conductive mass of the ground according to the regulations in force The electrical installation and the operating logic must comply with the regulations in force The leads fed with different voltages must be physically separate or they must be suitably insulated with additional insulation of at least 1 mm The leads must be secured with an additional fixture near the terminals During installati...

Страница 5: ...er a presettable time the system returns to the SLEEP mode WIRE DIAGRAM The electric connections shown in Fig 1 are described in the following table Terminals Function Description 1 2 Mains power supply Input mains power supply ESA BASIC accepts power supply voltages ranging from 85 to 260 VAC 3 COM Common to all control inputs 4 COM IN 1 Input contact of command 1 It is configurable for NO NC or ...

Страница 6: ... this allows to return to the upper menu without making any changes To speed up the increase decrease of values keep key or key pressed After waiting 30 seconds the control unit exits the programming mode and switches the display off PARAMETERS LOGICS AND SPECIAL FUNCTIONS The single functions available in the control unit are described in the following table MENU FUNCTION MIN MAX Default MEMO PAR...

Страница 7: ...h a transmitter code to be erased from memo ry If the code is valid it will be erased and OK is displayed on the monitor If the code is not valid or it is not in memory the message Err is displayed res The receiver memory is totally erased When the wording PUSH is displayed the operation must be confirmed During reset the RES wording flashes At end of reset OK is displayed MENU FUNCTION tar Measur...

Страница 8: ... of ESA BASIC The antenna of the control unit should be therefore disconnected and connected to the special inputs 22 23 The NC contacts of a safety edge shall be in any case connected to the special input of the control unit GATE STATUS INPUT One or more inputs can be preset in GATE STATUS INPUT mode In the input preset in this way a NO contact can be connected such as the SCA output contact of t...

Отзывы: