EC declaration of confirmity 

Manufacturer: 

Automatismi Benincà

 SpA.

Address: Via Capitello, 45 - 36066 Sandrigo (VI) - Italia

Herewith declares that: energy-saving device

 

 

ESA BASIC

.

complies with the following relevant provisions:
EMC guidelines: 

89/336/CCE, 93/68/CEE

Low voltage guidelines: 

73/23/CEE, 93/68/CEE

Benincà Luigi, Legal responsible.
Sandrigo, 08/04/2010.

WARNINGS

This  manual  has  been  especially  written  to  be  use  by 
qualified fitters.

None  of  the  information  provide  in  this  manual  can  be 
considered as being of interest for the end users. 

Preserve this manual for future needs. 

The technician has to furnish all the information related to 
the step by step function, the manual and the emergency 
function of the operator, and to deliver the manual to the 
final user. 

;

Foresee on the supply net an onnipolar switch or 
selector  with  distance  of  the  contacts  equal  or 
superior to 3 mms. 

Verify that of the electrical system there is an awry differ-
ential interrupter and overcurrent protection.

Some typologies of installation require the connection of 
the shutter to be link at a conductive mass of the ground 
according to the regulations in force.

The  electrical  installation  and  the  operating  logic  must 
comply with the regulations in force.

The leads fed with different voltages must be physically 
separate, or they must be suitably insulated with additional 
insulation of at least 1 mm.

The leads must be secured with an additional fixture near 
the terminals.

During installation, maintenance and repair, interrupt the 
power supply before opening the lid to access the electri-
cal parts

Check all the connections again before switching on the 
power.

The unused N.C. inputs must be bridged.

The descriptions and the present illustrations in this manual 
are not binding. Leaving the essential characteristics of the 
product  unchanged,  the  manufacturer  reserves  himself 
the  right  to  bring  any  change  of  technical,  constructive 
or  commercial  character  without  undertaking  himself  to 
update the present publication. 

TECHNICAL DATA

Mains power supply

From 85 to 260 VAC 50/60 Hz

Protection level

IP40

Operating temperature 

-20°C / +70°C

Radio receiver

433,92 MHz, incorporated and configurable

No. of codes storable in memory

512

Consumption in sleep mode

150 mW

Power contact range

16A/250Vac resistance load

Intelligent Security & Fire Ltd.

Содержание ESA BASIC

Страница 1: ...L8542643 06 2010 rev 0 ESA BASIC UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 2: ...5 14 13 12 11 10 23 22 21 20 19 18 17 16 OUT 1 COM IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 OUT 2 24 25 26 NO COM NC OUT 3 OUT 4 OUT 5 OUT 6 85 230Vac 50 60Hz RADIO F1 8 9 7 6 5 4 3 2 1 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 3: ...11 10 21 20 19 18 17 16 24 25 26 NO COM NC 85 230Vac 50 60Hz 8 9 7 6 5 4 3 2 1 PHOT OPEN CLOSE PED P P COM PHOT OPEN CLOSE PED P P COM ESA BASIC 23 22 ESEMPIO DI COLLEGAMENTO I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 4: ...t a conductive mass of the ground according to the regulations in force The electrical installation and the operating logic must comply with the regulations in force The leads fed with different voltages must be physically separate or they must be suitably insulated with additional insulation of at least 1 mm The leads must be secured with an additional fixture near the terminals During installati...

Страница 5: ...er a presettable time the system returns to the SLEEP mode WIRE DIAGRAM The electric connections shown in Fig 1 are described in the following table Terminals Function Description 1 2 Mains power supply Input mains power supply ESA BASIC accepts power supply voltages ranging from 85 to 260 VAC 3 COM Common to all control inputs 4 COM IN 1 Input contact of command 1 It is configurable for NO NC or ...

Страница 6: ... this allows to return to the upper menu without making any changes To speed up the increase decrease of values keep key or key pressed After waiting 30 seconds the control unit exits the programming mode and switches the display off PARAMETERS LOGICS AND SPECIAL FUNCTIONS The single functions available in the control unit are described in the following table MENU FUNCTION MIN MAX Default MEMO PAR...

Страница 7: ...h a transmitter code to be erased from memo ry If the code is valid it will be erased and OK is displayed on the monitor If the code is not valid or it is not in memory the message Err is displayed res The receiver memory is totally erased When the wording PUSH is displayed the operation must be confirmed During reset the RES wording flashes At end of reset OK is displayed MENU FUNCTION tar Measur...

Страница 8: ... of ESA BASIC The antenna of the control unit should be therefore disconnected and connected to the special inputs 22 23 The NC contacts of a safety edge shall be in any case connected to the special input of the control unit GATE STATUS INPUT One or more inputs can be preset in GATE STATUS INPUT mode In the input preset in this way a NO contact can be connected such as the SCA output contact of t...

Отзывы: